Optically pumped magnetometers (OPMs) based on the free-induction-decay (FID) configuration have recently attracted interest owing to their advantages, such as being calibration-free, easy to operate, and showing reduced light shifts induced by the pump light. Currently, alkali-metal vapor cells have been employed in most of the FID magnetometers. However, the relatively narrow linewidth of the magnetic resonance signal and nonlinear Zeeman (NLZ) effects generate bandwidth limitation and heading errors of these magnetometers in the Earth’s field, respectively. In this work, we propose a -based FID magnetometer, which not only has the advantages of being NLZ-free and showing a high bandwidth, but also maintains an enhanced sensitivity assisted by a multipass cell. This magnetometer demonstrates a magnetic field noise floor of with a Nyquist-limited bandwidth of kHz, which opens another route for atomic magnetometry using FID signals, and exhibits potential for applications in high-frequency magnetic field detection, such as biomagnetic measurements and magnetic communications in the geomagnetic field.
In this Letter, we propose a single-beam nonlinear magneto-optical rotation (NMOR) magnetometer with a multipass 4He gas-discharged cell. In contrast to the single-pass cell, the multipass cell allowed laser beams to pass through the metastable-state atomic ensemble 22 times, which directly increases the optical path length and significantly enhances magneto-optical rotation in the 4He gas sample. Based on nonlinear Faraday rotation, the 4He magnetometer with the multipass cell demonstrates a noise floor of 9 fT/Hz1/2, which approaches the photon-shot noise floor limit of 6.4 fT/Hz1/2. In addition, the wider linewidth in metastable-state atoms realizes an NMOR 4He magnetometer with a 3 dB bandwidth of 4.3 kHz, in contrast to the ultranarrow linewidth in the antirelaxation-coated cells or spin-exchange relaxation-free regime alkali-metal cells with buffer gas. Since the 4He cell functions without heating or cryogenic cooling, the femtotesla sensitivity and kilohertz-bandwidth 4He magnetometer exhibits potential in biomagnetic applications such as magnetocardiography and magnetoencephalography.
21 December 2023 in Microsystems & Nanoengineering
The development of mode-localized sensors based on amplitude output metrics has attracted increasing attention in recent years due to the potential of such sensors for high sensitivity and resolution. Mode-localization phenomena leverage the interaction between multiple coupled resonant modes to achieve enhanced performance, providing a promising solution to overcome the limitations of traditional sensing technologies. Amplitude noise plays a key role in determining the resolution of mode-localized sensors, as the output metric is derived from the measured AR (amplitude ratio) within the weakly coupled resonator system. However, the amplitude noise originating from the weakly coupled resonator’s closed-loop circuit has not yet been fully investigated. This paper presents a decouple-decomposition (DD) noise analysis model, which is applied to achieve high resolution in a mode-localized tilt sensor based on a weakly coupled resonator closed-loop circuit. The DD noise model separates the weakly coupled resonators using the decoupling method considering the nonlinearity of the resonators. By integrating the decoupled weakly coupled resonators, the model decomposes the weakly coupled resonator’s closed-loop circuit into distinct paths for amplitude and phase noise analyses. The DD noise model reveals noise effects at various circuit nodes and models the system noise in the closed-loop circuit of the weakly coupled resonators. MATLAB/Simulink simulations verify the model’s accuracy when compared to theoretical analysis. At the optimal operating point, the mode-localized tilt sensor achieves an input-referred instability of 3.91 × 10-4°and an input-referred AR of PSD of 2.01 × 10-4°⁄√Hz using the closed-loop noise model. This model is also applicable to other varieties of mode-localized sensors.
Differential single-beam saturated-absorption spectroscopy (DSSAS) is proposed to stabilize lasing frequency and suppress Doppler-broadened background and common-mode optical noise. The spectral first-derivative demodulated signal of metastable atoms is used as an error signal to stabilize a fiber laser around 1083 nm. Experimental results show that, compared with existing non-DSSAS frequency stabilization, DSSAS stabilization produces better stability and lower fluctuations, especially for frequency-noise-corrupted lasers. In DSSAS stabilization, for data acquired over 7000 s, the root mean square frequency fluctuation of the fiber laser is 16.4 kHz, and the frequency stability described by the modified Allan deviation is 4.1 × 10−12 at 100 s. Even for a defective laser with poor frequency stability, the proposed scheme demonstrates experimentally high capability of noise suppression and reduces the frequency fluctuations by two orders of magnitude. Given its simplicity and compact design, frequency stabilization by DSSAS is promising for quantum-sensor applications, such as atomic magnetometers, atomic gyroscopes, and atomic clocks.
For measurements in near-zero magnetic fields, vector atomic magnetometers are promising alternatives to scalar versions, but generally suffer from inconsistent performance over three axes. We present a single-beam vector magnetometer with three-axis isotropic sensitivity based on atomic alignment. Longitudinal parametric resonance with atoms pumped by linearly polarized light is proposed for the -axis measurement, while the Hanle effect in transverse geometry is used for - and -axis measurements. The evolution of atomic alignment multipole components and expressions of the three-axis magnetic responses are analyzed in detail. We describe the experimental operation of the proposed magnetometer with a magnetic-field noise floor of for the three axes, which is attractive for biomagnetism requiring vector characterization and source reconstruction.
Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 in both open- and closed-loop operations and has the potential to reach 70 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.