Anastasia Bulgakova

Mrs. Anastasia Bulgakova

Institute of Chemical Biology and Fundamental Medicine, Novosibirsk, Novosibirskaya Oblast’, Russia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2022 in Magnetochemistry
Verified
Journal Article
Open access
PDF file
ABAnastasia Bulgakova
Anastasia Bulgakova
Alexey ChubarovAlexey Chubarov
Alexey Chubarov
EDElena Dmitrienko
Elena Dmitrienko
Magnetic Fe3O4 nanoparticles (MNPs) have great potential for nucleic acid separation, detection, and delivery. MNPs are considered a valuable tool in biomedicine due to their cost-effectiveness, stability, easy surface functionalization, and the possibility of the manipulations under a magnetic field. Herein, the synthesis of magnetic nylon 6 nanocomposites (MNPs@Ny6) was investigated. Transmission electron microscopy (TEM) was used for morphology and size analysis. A new method of UV-induced immobilization of oligonucleotides on MNPs@Ny6 for nucleic acid magnetic separation was proposed. MNPs@Ny6 shows a high oligonucleotide binding capacity of 2.2 nmol/mg with 73.3% loading efficiency. The proposed system has been applied to analyze model mixtures of target RNA on the total yeast RNA background. The RNA target isolation efficiency was 60% with high specificity. The bind RNA release was 88.8% in a quantity of 0.16 nmol/mg. The total RNA capture efficiency was 53%. Considering this, the MNPs@Ny6 is an attractive candidate for nucleic acids-specific magnetic isolation.

3 February 2023 in Electronics
Verified
Journal Article
Open access
PDF file
ABAnastasia Bulgakova
Anastasia Bulgakova
ABAnton Berdyugin
Anton Berdyugin
ONOlga Naumova
Olga Naumova
BFBoris Fomin
Boris Fomin
DPDmitrii Pyshnyi
Dmitrii Pyshnyi
ALAlexander Lomzov
Alexander Lomzov
Nanowire or nanobelt sensors based on silicon-on-insulator field-effect transistors (SOI-FETs) are one of the leading directions of label-free biosensors. An essential issue in this device construction type is obtaining reproducible results from electrochemical measurements. It is affected by many factors, including the measuring solution and the design parameters of the sensor. The biosensor surface should be charged minimally for the highest sensitivity and maximum effect from interaction with other charged molecules. Therefore, the pH value should be chosen so that the surface has a minimum charge. Here, we studied the SOI-FET sensor containing 12 nanobelt elements concatenated on a single substrate. Two types of sensing elements of similar design and different widths (0.2 or 3 μm) were located in the chips. The drain-gate measurements of wires with a width of 3 µm are sufficiently reproducible for the entire chip to obtain measurement statistics in air and deionized water. For the pH values from 3 to 12, we found significant changes in source-drain characteristics of nanobelts, which reach the plateau at pH values of 7 and higher. High pH sensitivity (ca. 1500 and 970 mV/pH) was observed in sensors of 3 μm and 0.2 μm in width in the range of pH values from 3 to 7. We found a higher “on” current to “off” current ratio for wide wires. At all studied pH values, Ion/Ioff was up to 4600 and 30,800 for 0.2 and 3 μm wires, respectively. In the scheme on the source-drain current measurements at fixed gate voltages, the highest sensitivity to the pH changes reaches a gate voltage of 13 and 19 V for 0.2 μm and 3 μm sensors, respectively. In summary, the most suitable is 3 μm nanobelt sensing elements for the reliable analysis of biomolecules and measurements at pH over 7.