Pupillometry can be used as a method for monitoring pain. There are experimental conditions under which standard pupillometry equipment cannot be used. Studying the effects of different pulse forms used for transcutaneous spinal cord stimulation (tSCS) is one such task. The aim was to create a system for recording pupil diameter based on a web camera because it can be synchronised with external equipment, which allows the diameter to be recorded simultaneously with other physiological signals. A markerless system for recording and analysing pupil diameter using deep neural networks was developed based on a commercially available web camera. The accuracy of this system was compared with the accuracy of measurements using manual analysis with ImageJ (version 1.54g). For validation, the system was tested in a study of the dependence of tolerance to tSCS on the shape of stimulating pulses, which involved volunteers (n = 12). The results of the developed pupillometry were compared with the pain rating scale traditionally used in such studies. The developed system is accurate in determining the pupil diameter, comparable to human accuracy. The pupillometry results reproduced those obtained using a subjective pain scale. This method was found to be a reliable method for recording nociceptive pupillary responses in electrophysiology.
Objective. SMA is a genetic disorder that causes the progressive degeneration of spinal motor neurons, which can result in premature death. Restoring motor function in people with SMA is a serious issue. These individuals require lifelong motor rehabilitation to maintain their quality of life. A recent study showed that a two-week course of transcutaneous electrical spinal cord stimulation (tSCS) combined with physical therapy led to clinically significant improvements in Revised Upper Limb Module (RULM) and Hammersmith Functional Motor Scale Expanded (HFMSE), improved Forced Vital Capacity (FVC), reduced joint contractures in people with SMA types 2 and 3 receiving gene therapy. It is unclear how long the benefits of a tSCS course last. This study aimed to determine the long-term effects of tSCS and to evaluate whether consecutive tSCS courses can improve motor activity in individuals with SMA types 2 and 3 receiving disease-modifying therapy. Approach. Case series involved nine individuals with SMA types 2 and 3 (aged 5-20 years). They underwent two consecutive courses of tSCS combined with motor task performance. Each course lasted two weeks, with a break of 3 to 15 months between courses. The RULM, HFMSE, FVC and a goniometric assessment of knee extension were recorded before and after each course. Main results. Significant improvements achieved during the first course did not deteriorate between the courses. The second course demonstrated significant improvements in HFMSE scores and FVC. Significance. This case series confirms the effectiveness of tSCS in motor rehabilitation for individuals with SMA types 2 and 3. It can be concluded that the effects of spinal stimulation treatment last for 4 to 5 months. Consecutive tSCS courses with an interval of less than a year between them can likely improve motor activity in people with SMA types 2 and 3 who have received diseasemodifying therapy.
Pupillometry is a reliable method of pain control. There are experimental conditions under which standard pupillometry equipment cannot be used. Studying effects of different pulse forms used for transcutaneous spinal cord stimulation (tSCS) is one such task. The aim was to create a system for recording pupil diameter based on a web camera because it can be synchronized with external equipments, which allows the diameter to be recorded simultaneously with other physiological signals. A markerless system for recording and analyzing pupil diameter using deep neural networks was developed based on a commercially available web camera. The accuracy of this system was compared with the accuracy of measurements using manual analysis with the ImageJ. The system was tested in a study of the dependence of tolerance to tSCS on the shape of stimulating pulses, which involved the participation of volunteers (n=12). The results of the developed pupillometry were compared with the pain rating scale traditionally used in such studies. The developed system is accurate in determining the pupil diameter, comparable to human accuracy. The pupillometry results reproduced those obtained using a subjective pain scale. The developed method was found to be a reliable method for recording pain in electrophysiological studies.
24 May 2024 in Scientific and educational basics in physical culture and sports
Relevance: Researchers have shown that the characteristics of postural control in open-eyed children with visual impairment were higher than in sighted children, and these data are also associated with physical activity in their free time and the age at which they started playing sports. It is possible that people with visual or hearing impairments are more effective at maintaining balance, which may explain why they achieve similar or better results in posture control tasks compared to their normally developed peers.The aim of the study is to study the features of the statokinetic stability of athletes of three nosological groups: with hearing impairment, with visual impairment and with intellectual disabilities.Methods and organization of research. The method of stabilometry was used: the ST-150 stability platform and the STPL program. The area of the statokinesiogram (S, mm2); the average velocity of displacement of the pressure center (V, mm/s) and the energy consumption coefficient (Ke, conl. units) were studied.The results of the study and their discussion. When analyzing intra-group changes in athletes with hearing impairment, a significant deterioration in the function of static equilibrium was found in the test with closed eyes, which is typical for athletes with intellectual disabilities, but the results in the test with open eyes in these athletes are significantly better than in athletes with hearing impairment. Athletes with hearing impairment and athletes with intellectual disabilities have a pronounced forward asymmetry. In the sagittal plane, athletes with visual impairment have a pronounced asymmetry to the left. Normally balanced control revailed among athletes with hearing impairment. Normally balanced and proprioceptive control was revealed in athletes with visual impairment. Visual control prevailed among athletes with intellectual disabilities. The best statistical stability was revealed in athletes with intellectual disabilities, compared with athletes of the studied nosologies.Conclusions. Thus, the features of the statokinetic stability of athletes with hearing impairment, visual impairment and intellectual disabilities were revealed.