Carlalberto Francia

Dr. Carlalberto Francia

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2024
Verified
Book Chapter
Closed access
PDF file
CFCarlalberto Francia
Carlalberto Francia
FMFilippo Motta
Filippo Motta
Lucia DonnoLucia Donno
Lucia Donno
Mario CovarrubiasMario Covarrubias
Mario Covarrubias
CDCristina Dornini
Cristina Dornini
MGManuela Galli
Manuela Galli

24 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CFCarlalberto Francia
Carlalberto Francia
Lucia DonnoLucia Donno
Lucia Donno
FMFilippo Motta
Filippo Motta
Veronica CimolinVeronica Cimolin
Veronica Cimolin
MGManuela Galli
Manuela Galli
ALAntonella Lo LoMauro
Antonella Lo LoMauro
Markerless human pose estimation is increasingly used for kinematic assessment, but evidence of its applicability to upper limb movements across different ranges of motion (ROM) remains limited. This study examined the accuracy and reliability of a markerless pose estimation system for shoulder, elbow and wrist flexion–extension analysis under full and partial ROM tasks. Ten healthy participants performed standardized movements which were synchronously recorded, with an optoelectronic motion capture system used as a reference. Joint angles were compared using RMSE, percentage RMSE (%RMSE), accuracy (Acc), intraclass correlation coefficients (ICC), and Pearson correlation of ROM values. The markerless system reproduced the temporal morphology of the movement with high coherence, showing ICC values above 0.91 for the elbow and 0.94 for the shoulder in full ROM trials. Wrist tracking presented the lowest RMSE values and low inter-subject variability. The main critical aspect was a systematic underestimation of maximum flexion, especially at the shoulder, indicating a magnitude bias likely influenced by occlusion and joint geometry rather than by temporal fluctuations. Despite this limitation, the system adapted consistently to different ROM amplitudes, maintaining proportional variations in joint excursion across tasks. Overall, the findings outline the conditions in which markerless pose estimation provides reliable upper limb kinematics and where methodological improvements are still required, particularly in movements involving extreme flexion and occlusion.

14 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
CFCarlalberto Francia
Carlalberto Francia
Lucia DonnoLucia Donno
Lucia Donno
Mario CovarrubiasMario Covarrubias
Mario Covarrubias
GCGaetano Cascini
Gaetano Cascini
Marco TarabiniMarco Tarabini
Marco Tarabini
MGManuela Galli
Manuela Galli
In recent years, the application of ergonomics to workplace safety monitoring has gained increasing interest from companies and public institutions, allowing for the evaluation of the potential impact that dangerous situations may have on workers during their routine activities. This study presents a method for real-time monitoring of human physiological and motor responses to simulated workplace hazards during virtual reality safety training. The setup allows for precise measurements of both physiological and postural parameters during simulated scenarios. Moreover, a representative case study involving the sudden arrival of a forklift in a warehouse is presented. Five healthy participants were exposed to this scenario, with changes in heart rate variability and trunk posture being captured. The results demonstrate the effectiveness of sensor-based monitoring in detecting stress responses and postural adaptations to hazardous stimuli. This approach provides a basis for understanding human responses in simulated hazardous environments and may help to optimize safety training aimed at increasing workers’ risk perception and improving overall workplace safety. Although based on a small sample, the findings provide preliminary insights into the feasibility of sensor-based monitoring during VR safety training.

1 October 2025
Verified
Book Chapter
Closed access
CFCarlalberto Francia
Carlalberto Francia
Lucia DonnoLucia Donno
Lucia Donno
SCSerena Chiosso
Serena Chiosso
GPGiorgia Palotti
Giorgia Palotti
Marco TarabiniMarco Tarabini
Marco Tarabini
MGManuela Galli
Manuela Galli

21 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Lucia DonnoLucia Donno
Lucia Donno
CFCarlalberto Francia
Carlalberto Francia
FMFilippo Motta
Filippo Motta
ALAntonella Lo LoMauro
Antonella Lo LoMauro
CGCarlo Gorla
Carlo Gorla
MGManuela Galli
Manuela Galli
Ski mountaineering (Skimo) combines mountain climbing and skiing, with ascents on skis or by carrying them, followed by ski descents. Despite its popularity, the literature lacks integrated biomechanical analyses during indoor training, limiting evidence-based recommendations for training, injury prevention, and performance improvement in this sport. This study analyzed four Skimo athletes during uphill walking and running on a 9° inclined treadmill at 7 km/h and 8 km/h. Kinematics was assessed by an optoelectronic system, and surface electromyography recorded the muscular activity of twelve bilateral muscles (Erector Spinae, Rectus Abdominis, Rectus Femoris, Biceps Femoris, Tibialis Anterior, Gastrocnemius Lateralis). Rectus Femoris and Biceps Femoris co-activation supported knee stability during the load support phase, especially while running. Running at 8 km/h was the most demanding condition, with increased knee flexion throughout the task cycle. Switching from 7 to 8 km/h reduced the maximum extension and increased the maximum flexion of both hip and knee and required the Gastrocnemius’ recruitment in the swing phase. Regardless of task and speed, Rectus Abdominis and Erector Spinae played a key role in stabilizing the trunk. This study provided a biomechanical characterization of two motor gestures typical in Skimo, highlighting how task typology and velocity could influence kinematics and muscle activation.

29 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
CFCarlalberto Francia
Carlalberto Francia
Lucia DonnoLucia Donno
Lucia Donno
GSGaia Strada
Gaia Strada
Veronica CimolinVeronica Cimolin
Veronica Cimolin
Mario CovarrubiasMario Covarrubias
Mario Covarrubias
MGManuela Galli
Manuela Galli
Markerless video-based motion capture is a fast-developing, low-burden and versatile alternative to marker-based stereophotogrammetry, yet independent validation evidence for several commercial solutions is still scarce. This study validates the markerless software CapturyStudio (The Captury GmbH, Saarbrücken, Germany) for the reconstruction of upper- and lower-limb joint kinematics, comparing it with a validated Xsens (Movella, Henderson, NV, USA) inertial measurement unit system. Ten healthy subjects (five females and five males) performed two standardized clinical tasks, a Reach-To-Grasp gesture for the upper limb and a Timed-Up and Go test for the lower limb, recorded simultaneously with eight BTS SMART EVO-DX 2 (BTS Bioengineering S.p.A., Garbagnate Milanese, Italy) cameras operating in markerless mode and a 17-sensor Xsens system. Elbow, shoulder, knee and hip flexion–extension angles were reconstructed from three-dimensional anatomical keypoints provided by CapturyStudio and compared with the Xsens angles through root mean square error in absolute and percentage terms, range-of-motion accuracy, intraclass correlation coefficient (ICC), Spearman’s coefficient (ρ), Bland–Altman analysis and non-parametric Wilcoxon Rank-Sum tests. CapturyStudio reproduced the temporal pattern of all four angles faithfully (ICC ≥ 0.87; ρ ≥ 0.89), with median discrepancies of about 12° for the elbow and below 8° for shoulder, knee and hip and with the best agreement for the upper limb; the main weakness was a systematic overestimation of hip range of motion. Since both systems are indirect measurement techniques, these values represent the discrepancy between two methods and an upper bound on the error of the markerless system rather than its absolute accuracy. Their magnitude is comparable to the changes regarded as clinically meaningful in goniometric assessment, so the system is presently suited to the analysis of movement patterns rather than to the measurement of absolute joint angles. The study is to be read as a technical comparison of two measurement systems, delimiting the conditions under which future clinical, rehabilitation and sports applications may be pursued.