The introduction of point-of-care (POC) assays into clinical practice in patients with inflammatory disease enables on-demand therapeutic decision making. The aim of this study was to compare the POC test Quantum blue (Bühlmann Laboratories) for infliximab (IFX), adalimumab (ADL), and its anti-drug antibodies with the traditional ELISA assay (Promonitor). A total of 200 serum samples were analyzed. Samples were classified into the following three different groups; sub-therapeutic range (IFX < 3 μg/mL and ADL < 5 μg/mL); therapeutic range (IFX: 3–7 μg/mL and ADL: 5–12 μg/mL) and supra-therapeutic range (IFX levels > 7 μg/mL and ADL levels > 12 μg/mL). Significant higher values were measured using the POC test (p < 0.001) for IFX results but no differences in ADL trough levels were observed (p = 0.3101). Spearman’s correlation indicated a good correlation between the two assays (rs = 0.88 for ADL and rs = 0.93 for IFX), and McNemar’s test revealed significant differences (p = 0.016) when classifying IFX samples between therapeutic and supra-therapeutic ranges but no significant differences were found among the other ranges for either IFX or ADL. These results show that we should be cautious when using these rapid measurement methods, and new targets should probably be defined for IFX when using this new analytical method.
Therapeutic drug monitoring improves the benefit–risk balance of antipsychotic therapy. Ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) is considered the gold-standard method for measuring plasma drug concentrations; however, the Alinity C system has emerged as a promising alternative. This is the first study aimed at comparing UHPLC-MS/MS versus Alinity C in measuring plasma concentrations of aripiprazole and dehydroaripiprazole. A total of 86 plasma samples were analyzed. The active moiety of aripiprazole was measured in 60 samples using both systems and 26 samples were analyzed twice using Alinity C with an intermediate period of 6 months to assess its reproducibility. Spearman’s correlation revealed a good association between the two assays (rs = 0.96) and no significance differences were found by McNemar’s test when classifying samples between infra-, supra- and therapeutic ranges. Passing–Bablock regression showed a good correlation among methods (rs = 0.93) and a slope of 1.12 indicating a slight tendency of Alinity C to measure higher values than UHPLC-MS/MS. In addition, a good intra-method correlation across the two sequential analyses with Alinity C was obtained (rs = 0.99). Nonetheless, clinical decisions could be different in 15% of the cases depending on the chosen method. No differences were found in active moiety determination by Alinity C depending on the concentration of aripiprazole and dehydroaripiprazole of the samples.
Background/Objectives: Risperidone ISM® is a long-acting injectable (LAI) formulation approved for monthly administration in schizophrenia treatment. It employs innovative in situ microimplant technology for biphasic drug release, achieving immediate and sustained therapeutic plasma concentrations without the need for oral supplementation or loading doses. This study evaluates the pharmacokinetic profile of Risperidone ISM® in a real-world clinical setting, focusing on plasma concentrations of the active moiety (Risperidone + 9-OH-Risperidone). Methods: An observational study was conducted to measure plasma concentrations of patients receiving Risperidone ISM® (75 mg or 100 mg). Samples were collected at pre-dose, 2 h, 24 h, 14 days, 21 days, and 25 days post-injection. Pharmacokinetic parameters, including Cmax, Cmin, Tmax, and AUC, were calculated and stratified by dose (75 mg and 100 mg) and injection site (gluteal vs. deltoid). Results: A total of 44 patients were included. Therapeutic plasma levels were reached within hours post-injection and sustained throughout the 28-day interval. Cmin values averaged 34.4 ng/mL and 36.1 ng/mL for the 75 mg and 100 mg doses, respectively. The median Tmax occurred at 24 h with a mean Cmax of 55.7 ng/mL and 59 ng/mL for 75 mg and 100 mg, respectively. Higher systemic exposure was observed for deltoid administration. Significant interindividual variability was noted, with 45.4% of patients exhibiting trough levels outside the therapeutic range. Conclusions: Risperidone ISM® achieves rapid and sustained therapeutic plasma levels, offering significant benefits in schizophrenia treatment. However, the high interindividual variability observed must be thoroughly studied, and the contributing factors identified to ensure the therapy is as effective and safe as possible.
Background and objectives: Risperidone, a second-generation antipsychotic widely used in the treatment of schizophrenia, requires therapeutic drug monitoring due to its high interindividual variability. UHPLC-MS/MS is considered the gold standard for pharmacokinetic studies owing to its superior sensitivity and specificity, although it involves time-consuming manual sample preparation. In contrast, the Alinity C system, fully automated, simplifies sample processing, but only measures the active moiety (risperidone plus paliperidone). The aim of this study is to compare the performance of UHPLC-MS/MS and the Alinity C system for the determination of risperidone and paliperidone concentrations in plasma. Methods: A total of 115 plasma samples of 115 patients, 92 and 23 under risperidone and paliperidone long-acting treatment, respectively, were analyzed using both methods. Results: A strong correlation for the active moiety (risperidone plus 9-OH-Risperidone) (rs = 0.95) was observed. However, Bland–Altman analysis revealed a mean bias of 0.996 ng/mL, indicating that the Alinity C system slightly overestimates concentrations compared to UHPLC-MS/MS. While there was substantial agreement between methods (κ = 0.72), discrepancies were observed in 16.3% of cases, which could impact clinical decision-making. When analyzing paliperidone separately, the agreement was lower (κ = 0.63), with greater variability observed. Conclusions: These findings suggest that, while the Alinity C system is suitable for routine therapeutic monitoring, UHPLC-MS/MS remains the preferred method in clinical scenarios requiring higher precision, particularly for patients with concentrations near therapeutic thresholds.