This study presents the fracture behavior of synthetic fiber-reinforced structural lightweight aggregate concrete (SynFR-SLWAC) by experimental and analytical studies. Experimental studies include testing of 15 specimens for understanding mode-1 fracture response. Analytical studies include developing multilinear stress-crack width relations through inverse analysis. SynFR-SLWAC is made using sintered fly ash aggregate (SFA) with varying volume fractions of monofilament macro synthetic (0.2%, 0.4%, and 0.6%) and a small fraction of micro synthetic fibers (0.02%). The effect of synthetic fiber addition on the crack arresting mechanisms of SynFR-SLWAC is studied using the digital image correlation (DIC) technique. The stress-crack width relations are obtained from the experimental load-crack mouth opening displacement (CMOD) curves using inverse analysis. Additionally, empirical equations are proposed for predicting the stress-crack width relationship for SynFR-SLWAC with different fiber volume fractions. Fracture energy increased significantly with an increase in fiber volume dosage at larger values of crack width. Hinge width of SynFR-SLWAC reduced when compared to normal density concrete made of natural coarse aggregates.
This study investigates the effectiveness of hybrid fibers (steel and macro-synthetic) on the shear behavior of prestressed concrete beams. The hybrid fiber combination was selected to avoid workability issues at high volume dosages and ensure effective crack arresting over the crack opening range. Fracture studies included testing notched concrete prisms to identify the role of hybrid fibers in the crack bridging mechanism. Seven hybrid fiber reinforced prestressed concrete (HFRPC) beams were tested at a low shear span (a) to depth (d) ratio of 2.4. The effects of hybrid fibers on load–deflection behavior and strain in the strand are reported. Similarly, the crack opening, crack slip and crack angle variation regarding applied shear were investigated using the digital image correlation (DIC) technique. Test results of HFRPC beams showed considerable improvements in peak load and the post-peak response with a higher hybrid fiber dosage. The crack opening and crack slip measurement across the major shear crack revealed continuous dilatant behavior. The kinematic response of critical shear crack reflects the sustained dilation response up to the ultimate load, which depends on the critical shear crack angle of the tested beams. As the fiber dosage increases, the shear crack slip and width are reduced, indicating the roles of hybrid fibers in improving ductility and the change in failure mode from brittle shear tension to relatively ductile shear tension.