Deliang Chen

Mr. Deliang Chen

Beijing Institute of Technology, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DSDeshang Sha
Deshang Sha
XWXiao Wang
Xiao Wang
DCDeliang Chen
Deliang Chen
For current-fed dual active bridge bidirectional dc-dc converters, all the possible switching patterns are summarized in view of the combinations of both side pulse-width modulation duty cycles and phase-shift angle. A control strategy is proposed for the current-fed dual active bridge converter to operate with the optimized patterns. The equivalent duty cycle of the secondary side is smaller than that of the primary side by a fixed value, which is optimized based on the soft-switching achievement and the circulating current minimization. The closed-loop control is easy to be implemented since there are only two independent variables, one-side duty cycle and the phase-shift angle. With the proposed control, zero-voltage switching can be achieved for all power switches throughout full range of load even at no-load condition. The typical working modes with the proposed control are given. The optimal design of the system parameters including the fixed time delta and dead time is illustrated. The converter has a very good performance, not only under steady states but also in transients. The conversion efficiency is high. The effectiveness of the proposed control is verified by the experimental results of a 1-kW laboratory prototype.

22 March 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
NFNa Fu
Na Fu
JDJunjun Deng
Junjun Deng
Zhenpo WangZhenpo Wang
Zhenpo Wang
DCDeliang Chen
Deliang Chen
In this article, a triple-phase-shift (TPS) control strategy combining a switch-controlled capacitor (SCC) is proposed for LCC – LCC compensated wireless power transfer (WPT) system to improve the overall efficiency at wide output voltages. The basic mathematical model of the system is first established, and the conditions for zero-voltage switching (ZVS) and load matching are described under TPS. Then, the mechanism of TPS reducing system efficiency at wide output voltages is revealed based on the established model. An SCC is employed to adjust the compensation capacitance to achieve a minimum circulating reactive power on both sides and reduce the rectifier input current. Finally, the impact of the compensation capacitance variations on the current, output power, and impedance are analyzed, based on which the optimal value of adjustable capacitance for maximum efficiency is derived by further considering the established time domain model. A comparative experiment is performed with traditional TPS and the proposed control technique, which shows that the system with the proposed control technique achieves a higher efficiency over the TPS within the entire power range.

16 August 2021 in IEEE Access
Verified
Journal Article
Open access
WWwenbo wang
wenbo wang
JDJunjun Deng
Junjun Deng
DCDeliang Chen
Deliang Chen
Zhenpo WangZhenpo Wang
Zhenpo Wang
SWShuo Wang
Shuo Wang
Inductive power transfer (IPT) is an attractive wireless power charging option in many applications such as electric vehicle biomedical devices and consumer electronics, etc. Constant current and constant voltage (CC-CV) charging profile is widely used for charging applications due to affecting the life and the reliability of the Li-ion battery. However, the IPT systems that can achieve both CC and CV modes with soft switching are not well studied. This paper presents an inductive power transfer system for wireless charging without a back-end converter, which achieves the required two-stage charging profile with high efficiency by keeping inverters’ soft switching operation. The characteristics of an LCC-S compensation topology have been investigated thoroughly. Two fixed resonant frequencies, whose analytical expressions have been derived, can be found to realize constant current output and constant voltage output respectively under zero-phase angle condition. Besides, an effective tuning method has been presented for zero voltage switching realization to reduce the switching loss. Moreover, a parameter design procedure has been summarized for the wireless charger with a simplified structure and high efficiency. Finally, the method is validated through experiments on a 3.5kW prototype realizing constant current and constant voltage outputs with a peak efficiency of 97.3%.

2 February 2023 in IEEE Transactions on Vehicular Technology
Verified
Journal Article
Closed access
NFNa Fu
Na Fu
JDJunjun Deng
Junjun Deng
Zhenpo WangZhenpo Wang
Zhenpo Wang
DCDeliang Chen
Deliang Chen
In this paper, a dual-phase-shift control strategy combining with a switch-controlled capacitor (SCC) is proposed to realize efficiency maximization while realizing zero voltage switching (ZVS) for a LCC-LCC compensated wireless power transfer (WPT) system. The dual-phase-shift control is employed with a semi-active rectifier (SAR) to reduce the current stress in the resonant network. To realize accurate ZVS operation, both the SCC control angle and the SAR phase-shift angle are used as the control variables. First, the conditions of ZVS operation and circulating reactive power minimization are derived based on the time-domain model. Then, the power losses in the resonant network, inverter and semi-active rectifier are analyzed and optimized under the constant voltage output. An optimal control strategy is further proposed to maintain the constant voltage output while maximizing overall system efficiency. It is worth mentioning that the proposed control strategy allows the decoupling of the ZVS control and the power regulation. Finally, the performance of the proposed control strategy is examined based on a 6.6-kW WPT prototype. The results show that all switches realize ZVS operation within the entire power range with a peak system efficiency of 95.1%, which exhibits a good agreement with the theoretical analysis.

15 March 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DCDeliang Chen
Deliang Chen
JDJunjun Deng
Junjun Deng
WWWenbo Wang
Wenbo Wang
Zhenpo WangZhenpo Wang
Zhenpo Wang
A dual-transformer-based hybrid dual active bridge (DAB) converter for plug-in electric vehicle charging to cope with wide load voltages is introduced in this article. The control degrees of freedom are extended by splitting the leg and transformer of the conventional DAB converter (CDABC) in two parts. Based on the numerical analysis, the full-domain four-variable closed-form optimal trajectories targeting at the minimum root mean square value of the leakage inductor current is attainted, and the unified-segmental control strategy is proposed to handle the working modes shifting without the current inrush. As a result, the conduction losses and switching losses can be significantly reduced in boost mode compared to CDABC. The discussed converter and control strategy are verified by a 1.0-kW prototype.

27 November 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
DSDeshang Sha
Deshang Sha
DCDeliang Chen
Deliang Chen
JZJiankun Zhang
Jiankun Zhang
A high frequency isolated bidirectional three-level DC-DC converter is proposed for battery charging/discharging applications. To reduce the circulating loss, a double PWM plus double phase shifted control with voltage matching control is proposed. ZVS for all switches can be obtained throughout full load range even at no load condition by using the transformer magnetizing current. The mode analysis is given to illustrate its working principle. The system parameters design criterion is given in view of the efficiency improvement and ZVS achievement for all switches. A detailed comparison of root mean square (rms) value and peak value of the leakage inductor current is made with the voltage matching control and mismatching control respectively. The conversion efficiency curves using the proposed control and PWM plus phase shift (PPS) control have been compared. The effectiveness of the proposed control for the DC-DC converter is verified by experimental results of a 1kW three-level prototype.