In endoscopic biliary drainage (EBD) for various benign and malignant biliary disorders, the appropriate timing to replace or change a plastic stent (PS) with a self-expandable metallic stent (SEMS) remains unclear. This study aimed to define the best period to replace or change a PS with a SEMS. Between January 1, 2012, and December 31, 2018, 1,887 consecutive EBD procedures, including 170 SEMS placements, were retrospectively identified. The period to recurrent biliary obstruction (PRBO) was estimated and compared between the malignant and benign groups and according to each disease using time to event analysis and competing risk analysis. Compared with the benign group, the malignant group had significantly shorter median PRBO with interquartile range (IQR) after PS placement [108 (39 – 270) vs. 613 (191 – 1,329) days, P < 0.001], even on multivariate analysis, with a subdistribution hazard ratio (SHR) of 3.58 (P < 0.001). The shortest PRBO distribution from the first quartile of the non-RBO period was seen in Mirizzi syndrome cases (25 days, P = 0.030, SHR = 3.32) in the benign group and in cases of pancreatic cancer (32 days, P = 0.041, SHR = 2.06); perihilar bile duct cancer (27 days, P = 0.006, SHR = 2.69); and ampullary cancer (22 days, P = 0.001, SHR = 3.78) in the malignant group. Our study supports that stent replacement for the benign group is feasible after 6 months, and the best period to replace or change a PS with a SEMS should be decided on the basis of the underlying disease to prevent RBO.
Specimens obtained with endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) are often tiny and fragmented leading to an inconclusive and doubtful diagnosis. To overcome the limitations of EUS-FNA in the cytological diagnosis of pancreatic adenocarcinoma (PCA), we evaluated whether quantification of the S100P protein combined with EUS-FNA reliably discriminated between PCA and benign pancreatic lesions (BPL). A high sensitivity sandwich ELISA for S100P protein was developed to aid in the detection of PCA in small samples obtained using EUS-FNA. After experimental verification of the sandwich ELISA with cell lines and mouse xenograft tumors, 27 consecutive patients with suspicious PCA who underwent EUS-FNA were enrolled in the present study examining the combination of S100P protein assessment and EUS-FNA cytology. The concentration of the S100P protein in EUS-FNA samples from the PCA group was significantly higher than that in the BPL group (P=0.04). Using receiver operating characteristic curve analysis, we determined the S100P protein cut-off value for PCA diagnosis to be 99.8 ng/ml. The S100P protein levels combined with EUS-FNA cytology to detect PCA showed the following diagnostic values: sensitivity, 94.4% [95% confidence interval (CI), 75.7-99.1%]; specificity, 88.9% (95% CI, 51.8-99.7%); positive predictive value, 94.4% (95% CI, 72.7-99.9%); negative predictive value, 88.9% (95% CI, 51.8-99.7%); accuracy, 92.6% (95% CI, 75.7‑99.1%); and area under the curve, 0.92 (95% CI, 0.79-1.00). We established a novel quantitative analysis for the S100P protein in EUS-FNA samples which, when combined with EUS-FNA cytology, could provide promising results for the reliable diagnosis of PCA.
Background: The utility of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) alone in the biliopancreatic region appears to be limited because it is highly dependent on the experience and skill of the endoscopist. Therefore, the present study aimed to validate the efficacy of CH-EUS in clinical practice. Methods: Between January 2018 and March 2019, 301 consecutive patients who underwent CH-EUS were prospectively enrolled in this study. The diagnostic performance of CH-EUS was compared with that of dynamic computed tomography (CT), magnetic resonance imaging (MRI), and all combinations (i.e., CH-EUS, dynamic CT, and MRI) using a Bonferroni correction. A multiple logistic regression analysis was performed to extract each disease that allowed the CH-EUS diagnosis to be consistent with the final diagnosis. Results: In multiple comparisons of diagnostic performance, no significant differences were observed among dynamic CT, MRI, and CH-EUS (p = 1.00), but the diagnostic performance was significantly higher when all modalities were combined (p < 0.001). Moreover, only intraductal papillary mucinous neoplasm comprising adenoma or carcinoma (IPMN, n = 161) showed significance with respect to the agreement with the final diagnosis (p = 0.006). Conclusions: Our results showed that CH-EUS-based diagnosis of IPMN may be possible in clinical practice. On the contrary, to accurately diagnose biliopancreatic diseases other than IPMN, comprehensive diagnosis using multiple modalities may be necessary, rather than relying on CH-EUS alone.
Background: Pancreatic cancer (PC) has a very poor 5-year survival and prognosis. Even when CT or MRI shows no metastasis, staging laparoscopy(SL) still detects tiny peritoneal deposits in 20–30% of patients, making them ineligible for surgery. SL is invasive, requiring general anesthesia and substantial resources. Endoscopic ultrasound (EUS) allows the observation of the bile ducts, pancreas, and abdominal cavity, and EUS-guided fine-needle aspiration (EUS-FNA) is essential for pathological diagnosis. Reports on using EUS to perform peritoneal lavage cytology are currently not available. We hypothesized that combining EUS-FNA with peritoneal lavage (EUS-lavage technique; EUS-LT) could enhance staging accuracy and avoid unnecessary surgical procedures. Methods: Ten in vivo porcine models underwent EUS-LT. Using a 19G FNA needle, 800 mL saline was instilled into the intraperitoneal cavity and then recovered. Two refinements were introduced sequentially: an ENBD catheter with additional side holes and, subsequently, a side-hole introducer (EndoSheather) that eliminated balloon dilation. The primary endpoint was procedural success. Secondary endpoints included safety, complications, recovered volume, duration of endoscopic procedure, and time required to instill 800 mL. Nonparametric tests compared outcomes across iterations. Results: Ten-model porcine in vivo model series were included, and all procedures were successful. No device malfunctions or unanticipated technical failures; one minor mucosal injury during saline injection resolved after re-puncture. The average procedure time was 31.1 min. Stepwise refinements shortened procedure and infusion times and increased recovered volume. Recovered volume approached the instilled amount in later cases, indicating efficient performance. Conclusions: In this ten-model in vivo series, EUS-LT demonstrated technical feasibility and short-term safety.