Chivon Choeung

Dr. Chivon Choeung

Faculty of Electricity, National Polytechnic Institute of Cambodia, Phnom Penh, Cambodia
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2024 in International Journal of Electrical and Electronics Research
Verified
Journal Article
Open access
PDF file
SISokvan In
Sokvan In
SASovann Ang
Sovann Ang
Chivon ChoeungChivon Choeung
Chivon Choeung
SISokun Ieng
Sokun Ieng
HCHorchhong Cheng
Horchhong Cheng
VHVichet Huy
Vichet Huy
The power system has been expanded to supply and fulfil the consumers’ requirements for reliability, affordability, and power quality. Power loss reduction and voltage stability enhancement are important points and have been considered interesting subjects for researchers and utilities. Furthermore, reactive power plays an important role in power system stability, security, and voltage improvement, and it is known as reactive power dispatch (RPD). In this paper, a newly developed meta-heuristic optimization technique that inspired the gorilla troop’s social intelligence in nature is applied. It is named Artificial Gorilla Troop Optimization (GTO). In addition, GTO is utilized to solve the optimal reactive power dispatch (ORPD) problem, whose real active power and voltage deviation reduction are the objective functions of this study. Generator voltage, transformer tap-changers, and reactive power compensators are the controlled variables that are optimized for achieving the minimum real power loss and bus voltage deviation. To illustrate the efficiency and performance of the proposed algorithm, IEEE 14-bus and 30-bus systems are employed. Moreover, the obtained results are compared with those obtained with other three already existing optimization algorithms, including the genetic algorithm (GA), particle swarm optimization (PSO), and whale optimization algorithm (WOA). Obviously, the proposed approach can prove the optimal values of controlled variables in solving the ORPD problem by giving the minimum real power loss and voltage deviation than those from compared techniques with less computation time.

30 August 2022 in Journal of Advanced Transportation
Verified
Journal Article
Open access
PDF file
Chivon ChoeungChivon Choeung
Chivon Choeung
MKMeng Leang Kry
Meng Leang Kry
YLYoung II Lee
Young II Lee
This paper presents a robust control strategy for an electric vehicle's three-phase off-board bidirectional AC-DC battery charger. The conventional constant current (CC) and constant voltage (CV) charging mode are considered to provide a fast-charging performance for the batteries. The bidirectional charger also allows using of the vehicle as an energy storage system for the grid i.e., charging during the peak-off times and delivering the energy back to the grid during peak times of electrical consumption. In discharging mode, the bidirectional charger maintains constant active power flow to the grid with a given reference. For both cases, user of a robust state feedback controller with integral action is made in the DQ-synchronous frame. The set of stabilizing gains of this controller are determined by a linear matrix inequality (LMI)-based optimization so that the convergence time to steady stead is minimized in the occurrence of the parametric uncertainties of the L-filter. The efficacy of the proposed controller is verified through simulation and experimental results on 102.4V Lithium iron phosphate (LiFePO4) batteries.

3 December 2018 in Energies
Verified
Journal Article
Open access
PDF file
Chivon ChoeungChivon Choeung
Chivon Choeung
MKMeng Leang Kry
Meng Leang Kry
YLYoung II Lee
Young II Lee
This paper presents a robust control technique for three-phase chargers under unbalanced grid conditions. The control method consists of inner-loop robust grid-current control and outer-loop proportional integral control for constant current (CC) and constant voltage (CV) control. A dual-current control for the inner-loop positive and negative sequence is employed to eliminate the unbalanced current caused by the grid so that a constant current and voltage can be provided to the batteries. The inner-loop robust controllers utilize state feedback with integral action in the dq-synchronous frame. A linear matrix inequality-based optimization scheme is used to determine stabilizing gains of the controllers to maximize the convergence rate to steady state in the presence of uncertainties. The uncertainties of the system are described as the potential variation range of the inductance and resistance in the L-filter.

1 January 2016 in IFAC-PapersOnLine
Verified
Conference Paper
Closed access
Chivon ChoeungChivon Choeung
Chivon Choeung
SPSeong Hwan Park
Seong Hwan Park
BKByung Kwon Koh
Byung Kwon Koh
YLYoung Il Lee
Young Il Lee

18 January 2023
Verified
Conference Paper
Closed access
Chivon ChoeungChivon Choeung
Chivon Choeung
Heng TangHeng Tang
Heng Tang
Panha SothPanha Soth
Panha Soth
SKSothim Keo
Sothim Keo
PLPhearit Leang
Phearit Leang
VHVichet Huy
Vichet Huy
This paper discusses a systematic control design for a three-phase L-filtered grid-connected inverter using linear matrix inequality-based optimization method. A state feedback control is employed to provide stability to the inverter system and with the inclusion of integral control the offset error can be eliminated. In addition, the proposed control is implemented in dq-synchronous frame with help from a phase locked-loop to track the grid phase angle. The optimization criterion of this proposed control is to reduce the convergence time to the steady state as short as possible. The set of robust stabilizing gain is systematically discussed in this paper and computed using MATLAB toolbox. Then, the effectiveness of this proposed control algorithm is verified by implementing on PSIM simulation tool.

8 March 2023
Verified
Conference Paper
Closed access
Panha SothPanha Soth
Panha Soth
HTHeng Tang
Heng Tang
BSBunne So
Bunne So
SSSokna San
Sokna San
HCHorchhong Cheng
Horchhong Cheng
COChanmoly Or
Chanmoly Or
In this paper, a robust dual-current control is proposed for a three-phase grid-tied inverter under unbalanced grid voltage. To compensate the unbalanced grid current rooted by the grid voltage dips or faults, an additional negative sequence compensator is considered in this proposed controller. The current control for both positive and negative sequence utilizes state feedback with integral control to archive fast reference tracking without steady-state error. The robust control gain is computed by solving a linear matrix inequality-based optimization problem to obtain fast convergence rate in the presence of the uncertainty of the system. The positive sequence current reference is used to regulate the amount of current flow from DC source to the grid, and the zero negative sequence reference is used to compensate the unbalanced grid current. To verify the efficacy of this control method, a comparison between the proposed robust dual-current control and robust current control without negative sequence compensator is conducted using simulation.