Chong Lye Lim

Dr. Chong Lye Lim

PSB Academy, Singapore, Central Singapore, Singapore
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2024 in Electronics
Verified
Journal Article
Open access
PDF file
WCWei Feng Don Chua
Wei Feng Don Chua
Chong Lye LimChong Lye Lim
Chong Lye Lim
YKYit Yan Koh
Yit Yan Koh
Chiang Liang KokChiang Liang Kok
Chiang Liang Kok
In Singapore’s limited land space, hydroponics, a soil-free method of that uses irrigation gained popularity for urban farming. Vertical farming can be made more sustainable by integrating Internet-of-Things (IoT) and solar photovoltaic (PV) as an intelligent system. This study aims to conduct a feasibility study on using PV cells to reduce energy consumption in IoT-enabled irrigation control and monitoring systems. In the experiment, an intelligent water irrigation system was designed for data collection including energy harvested from PV, climate conditions, and water quality. It was observed that a 45 Watt peak (Wp) solar PV was able to produce up to 460-watt hours of stored electricity in a day which can power a standalone hydroponic system that consists of a 19 W water pump and light emitting diode (LED) grow lights rated at 14 W/m. The climate monitoring system matched meteorological data from online sources proving to be applicable in the prototype. Water conditions such as water temperature and electrical conductivity (EC) also correlate to readings taken from traditional handheld water quality testers. Based on the fabricated prototype, integration is deemed to be feasible using power harvested from the sun.

1 September 2018 in Thermal Science and Engineering Progress
Verified
Journal Article
Closed access
Chong Lye LimChong Lye Lim
Chong Lye Lim
NANor Mariah Adam
Nor Mariah Adam
KAKamarul Arifin Ahmad
Kamarul Arifin Ahmad

5 December 2021 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
MAMohammed W Muhieldeen Al-Gailani
Mohammed W Muhieldeen Al-Gailani
Chong Lye LimChong Lye Lim
Chong Lye Lim
MKMohammed Sameer Sharaf Kassim
Mohammed Sameer Sharaf Kassim
WTWah Yen Tey
Wah Yen Tey
KTKah Hou Teng
Kah Hou Teng
Now a days, the global warming has increased the temperature in the environment that forced the building occupant to get assisting from the air condition to reduce the heat tension inside the building, this could increase the electricity bill amount. The aim of this study is to measure the optimum thickness of Rockwool insulation to experimentally and numerically to reduce the heating load inside the buildings. Two devices have been used through this research, Infrared Thermometer to measure profile temperature of the walls along with VELOCICALC to measure the air temperature and air velocity. Three different layers of Rockwool insulation have been applied on the roof of wooden room. The data present the two layers thickness of Rockwool is the best selection to reduce the heating load inside the room, the differential between outside and inside is 0.9 °C, the Rockwool of one layer reduced only 0.5 °C and the maximum thickness with three layers reduced only 1 °C, which is not much effective compared to the two layers but even more costly. CFD analysis shows agreement with the experimental result. The results shows if the dimensions of a UCSI lecture room is to be considered, then applying Rockwool insulation with a thickness of 100 mm would cost around RM 1520 as a UCSI lecture room is of 8 m width and 9 m length. However, two layers of Rock wool insulation could save around 29.30% of ROI per annum.

24 May 2022 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
ASAbhiviran Vimal Subramaniam
Abhiviran Vimal Subramaniam
MMMohammed W. Muhieldeen
Mohammed W. Muhieldeen
RTRodney Tan
Rodney Tan
Chong Lye LimChong Lye Lim
Chong Lye Lim
The amount of carbon emission pumped into the atmosphere has led to a rise in global temperature. Rapid urbanization increased the use of air conditioners, resulting in the urban heat island effect. The use of environmentally friendly methods in reducing energy consumption for buildings is needed now more than ever. This study aims to evaluate the cooling load of a prototype by installing a shading plate above its roof at a height of 0.67m. A wooden panel with an attached aluminium sheet is used as a shading plate, 2m by 0.9m. The prototype with a dimension of 0.80m (L) x 0.50m (W) x 0.97m (H) is a scaled-down model of the guardhouse located near Block E, UCSI University. Along with the shading plate, the prototype is placed nearby the guardhouse to validate the actual guardhouse's exact condition. The shadow acts as an insulator to the prototype. There were two devices used for data collection; a VELOCICALC thermometer to measure the air velocity and air temperature and an infrared thermometer to measure the profile temperature of the room walls, roof, and floor. To ensure the prototype is adequately ventilated, it was placed 20 cm above the floor using red bricks from 9 a.m. to 5 p.m, a maximum temperature reduction of 4.5°C when the shading plate thoroughly shades the room. A total of 14.5% electricity cost can be reduced monthly when the guardhouse is fully shaded from 11 a.m. to 2 p.m. In contrast, both the actual guardhouse and the prototype model can receive full sunlight from 11 a.m. to 5 p.m., while from early morning till 11 a.m., the guardhouse is fully shaded by the UCSI Block E building.

1 February 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
MSMahmud Iwan Solihin
Mahmud Iwan Solihin
MWMah Chia Wen
Mah Chia Wen
FHFahri Heltha
Fahri Heltha
Chong Lye LimChong Lye Lim
Chong Lye Lim
PID (proportional+integral+derivative) controller is well known as a simple and easy-to-implement controller. However, the design procedure is not straightforward for multi-input multi-output (MIMO) systems. It is even more complicated when robustness criterion must be handled. In this paper, a stable robust PID controller for anti-swing control of automatic gantry crane is proposed. The proposed method employs an automatic tuning using DE (differential evolution) to search for a set of PID controller gains that satisfy Kharitonovs polynomials robust stability criterion. This robust stability criterion is used to deal with parametric uncertainty occurs in gantry crane model. The simulation results show that a satisfactory robust PID control performance can be achieved. The PID controller is able to quickly move the cart of the crane while suppressing the swing of the payload for various conditions, i.e. payload mass and cable length variations.

11 August 2022
Verified
Book Chapter
Closed access
PDF file
Chong Lye LimChong Lye Lim
Chong Lye Lim
HRHashwinni Rajaretnam
Hashwinni Rajaretnam
STSarina Tajudin
Sarina Tajudin
MAMohammed W Muhieldeen Al-Gailani
Mohammed W Muhieldeen Al-Gailani