This study presents the transmission of SARS-CoV-2 in the main types of public transport vehicles and stations to comparatively assess the relative theoretical risk of infection of travelers. The presented approach benchmarks different measures to reduce potential exposure in public transport and compares the relative risk between different means of transport and situations encountered. Hence, a profound base for the selection of measures by operators, travelers and staff is provided. Zonal modeling is used as the simulation method to estimate the exposure to passengers in the immediate vicinity as well as farther away from the infected person. The level of exposure to passengers depends on parameters such as the duration of stay and travel profile, as well as the ventilation situation and the wearing of different types of masks. The effectiveness of technical and behavioral measures to minimize the infection risk is comparatively evaluated. Putting on FFP2 (N95) masks and refraining from loud speech decreases the inhaled viral load by over 99%. The results show that technical measures, such as filtering the recirculated air, primarily benefit passengers who are a few rows away from the infected person by reducing exposure 84–91%, whereas near-field exposure is only reduced by 30–69%. An exception is exposure in streetcars, which in the near-field is 17% higher due to the reduced air volume caused by the filter. Thus, it can be confirmed that the prevailing measures in public transport protect passengers from a high theoretical infection risk. At stations, the high airflows and the large air volume result in very low exposures (negligible compared to the remaining means of transport) provided that distance between travelers is kept. The comparison of typical means of transport indicates that the inhaled quanta dose depends primarily on the duration of stay in the vehicles and only secondarily on the ventilation of the vehicles. Due to the zonal modeling approach, it can also be shown that the position of infected person relative to the other passengers is decisive in assessing the risk of infection.
The idea of using air cabs urban mobility is increasingly becoming a reality. In this project, research is conducted on an energy-efficient air conditioning system for an air cab to efficiently combine range and comfort in the cabin. For this, both simulations using a zonal model are conducted, and a thermal air cab demonstrator platform is developed. Measurements in the air cab demonstrator are used to investigate passenger comfort under various climatic conditions, including warm and moderate environments. In addition, the study focuses on evaluating the energetic efficiency of various air conditioning systems such as air cooling and close-to-body climatization. The data analysis compares user comfort and energy efficiency across technologies based on established comfort standards. This allows recommendations for energy-efficient air conditioning to be identified.
This study investigates the spread and removal of emissions from a liquid hydrogen tank in a leakage case in the rear area of a hybrid-electric regional aircraft. The aim of the research is to determine the air volume flows that a fan is required to supply to keep the hydrogen concentration below 1% by volume in the event of a leak. In addition, the fan position with the best possible hydrogen removal is to be identified. For this purpose, the geometry of a 10.6 m3 sized tank and compartment is reconstructed, and a zonal simulation model is created that represents the air flow patterns within the domain. Using this simulation model, a comprehensive parameter study is carried out in which different configurations of fan arrangements and leakage scenarios are simulated. The results of these simulations are analyzed and compared to determine the most efficient ventilation to maintain safe hydrogen concentrations.
The vision of eVTOLs (electric vertical take-off and landing vehicles) aims to transport individuals autonomously in urban areas using electrically powered aircraft. The efficiency, and thus the operational range of these aircraft, is crucial for market introduction. However, battery capacity is limited, necessitating effective thermal management for power electronics, drive components, and cabin climatization. This project focuses on optimizing the thermal management of the overall architecture of an eVTOL to enhance efficiency and performance. The developed framework for thermal modeling enables simulation-based design studies and provides the basis for future optimization tasks. The modeling structure considers components as well as the overall thermal system of an eVTOL. This framework includes detailed models of the cabin, cockpit, avionics bays, and battery zones, analyzing their specific thermal properties and interactions with one another. Various cooling strategies, including air and liquid circuits, are evaluated to meet the requirements for both indoor air quality and system components. These findings indicate that increasing ventilation mass flows can significantly enhance thermal passenger comfort, thus meeting comfort requirements. Energy consumption analysis shows that compressor efficiency is critical for overall system performance. The parametric study further shows that compressor efficiency and bypass control have the strongest influence on total energy demand. In the best-case configuration, the thermal management energy consumption can be reduced by 95% compared to the reference case. This research highlights the necessity for an integrated thermal management approach in eVTOL design, paving the way for future experimental validation and optimization efforts.