Sparse spiral phased arrays are advantageous for many emerging air-coupled ultrasonic applications, since grating lobes are prevented without being constrained to the half-wavelength element spacing requirement of well-known dense arrays. As a result, the limitation on the maximum transducer diameter is omitted and the aperture can be enlarged for improving the beamforming precision without requiring the number of transducers to be increased. We demonstrate that in-air imaging, in particular, benefits from these features, enabling large-volume, unambiguous and high-resolution image formation. Therefore, we created an air-coupled ultrasonic phased array based on the Fermat spiral, capable of transmit, receive and pulse-echo operation, as well as 3D imaging. The array consists of 64 piezoelectric 40-kHz transducers (Murata MA40S4S), spanning an aperture of 200 mm. First, we provide an application-independent numerical and experimental characterization of the conventional beamforming performance of all operation modes for varying focal directions and distances. Second, we examine the resulting imaging capabilities using the single line transmission technique. Apart from the high maximum sound pressure level of 152 dB, we validate that unambiguous high-accuracy 3D imaging is possible in a wide field of view (±80°), long range (20 cm to 5 m+) and with a high angular resolution of up to 2.3°. Additionally, we demonstrate that object shapes and patterns of multiple reflectors are recognizable in the images generated using a simple threshold for separation. In total, the imaging capabilities achieved are promising to open up further possibilities, e.g. robust object classification in harsh environments based on ultrasonic images.
10 January 2022 in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
In this work we combine a multipath ultrasonic gas flow meter (UFM) with an ultrasonic air-coupled phased-array. This allows complementing the advantages of a multipath UFM, i.e. higher accuracy and more robustness to irregular flow, with the extended velocity measuring range due to sound drift compensation via a phased-array. We created a 3D-printed flow meter consisting of an 8×8 λ/2 phased-array for transmission and 14 individual receivers for seven upstream and seven downstream sound paths. Measurements were conducted in a test rig with a maximum gas flow rates of 8.3m3 s-1 (107ms-1). A differential pressure nozzle was used as reference sensor. Three configurations were compared: Parallel sound paths with a single transmitter; parallel sound paths with the phased-array as transmitter; and fan-shaped sound paths with the phased-array as transmitter. The signal-to-noise ratio (SNR) and deviation of measured flow were used as comparison criteria. In addition, we measured the optimum steering angles of the phased-array required to compensate the sound drift effect. Using the phased-array with the sound drift effect compensation enabled and disabled, the SNR increases by 10.6 dB and 4.95 dB, respectively, compared to the single transmitter setup at 83ms-1. Furthermore, the phased-array with compensation active, extends the velocity measuring range by 29%, from 83ms-1 to 107ms-1, while maintaining a similar standard deviation of the flow measured. Besides demonstrating that a phased-array in a gas flow meter significantly extends the measurement range, our setup qualifies as versatile research platform for designing future high-velocity gas flow meters.
7 August 2023 in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
Sparse array designs are a promising approach to improve the beam pattern and imaging quality, especially for applications, where hardware resources are severely limited. In particular, spiral sunflower arrays become increasingly popular due to their excellent point-spread-function (PSF) characteristics and their simple, deterministic and scalable design. Therefore, several sunflower modifications for further improvement have been investigated, e.g. density tapering based on window functions adapted from apodization techniques. In this article, we introduce a two-scale spiral array design concept, which exploits the specific PSF structure of the sunflower geometry, instead of relying on window functions. The modification proposed combines two nested sunflower sub-arrays featuring two different spatial element densities such that the locations of their respective main, side and grating lobe zones differ, resulting in a balanced and improved composite one-way PSF in terms of main lobe width (MLW) and maximum side lobe level (MSLL) under far-field and narrow-band conditions. First, we provide an analysis of the unmodified classic sunflower geometry, describe its PSF zones and show how their locations in the PSF can be estimated based on the array design parameters, which finally leads to the two-scale concept. Second, we examine a specific well-matching combination of nested sub-arrays to discuss the advantages and limitations of the resulting PSF. Third, we benchmark the respective optimum arrays of the classic sunflower and density tapering strategies with the two-scale method, where the latter shows an improved performance of the one-way PSF in terms of MLW and MSLL. Fourth, the two-scale design strategy is validated using a real-world 64-element prototype for narrow-band ultrasound imaging in air. We conduct two experiments to analyze the resulting PSF and angular resolution. Overall, the results demonstrate that the proposed flexible four-parameter concept is particularly valuable for high frame rate imaging as well as for transmit-only and receive-only applications.
We present an ultrasonic transit-time gas flow meter (UFM) based on our 40 kHz 8 8 phased-array. Besides single element receivers, the UFM uses×a waveguide-based phased-array with an inter-element spacing of half-lambda as sender, capable of electronic beam steering for an extra-large flow velocity range. The sound drift effect limits the measurement range of conventional UFMs, i.e. we compensate the sound-drift effect using beam steering. The UFM features a maximum measurable flow velocity up to 100 m s −1 . The flowmeter body is a fully 3D-printed pipe with a length of 800 mm and an inner diameter of 315 mm. The receivers are arranged at inclination angles of 45 ◦ . The flowmeter is tested on a test rig for ventilation fans according to ISO 5801:2017(E). At zero flow velocity, the SNR for the downstream receiver is 64.1 dB. Without compensation of the sound-drift effect, at the full flow velocity of 100 m s −1 , the SNR drops down to 18.0 dB (downstream). When the compensation is enabled, the SNR raises by 18.7 dB (downstream) at full flow velocity. These numbers proof that the usage of a phased-array in a UFM can significantly increase the maximum measurable flow velocity. Further advantages are the possibility of multi-path measurements for an improved meter factor, i.e. eccentric flow meter configurations.