Cinthia Estefania Padilla Gallegos

Ms. Cinthia Estefania Padilla Gallegos

LEQUIA, University of Girona, Girona, Catalonia, Spain
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2025 in Applied Water Science
Verified
Journal Article
Open access
PDF file
Cinthia Estefania Padilla GallegosCinthia Estefania Padilla Gallegos
Cinthia Estefania Padilla Gallegos
Gaetan BlandinGaetan Blandin
Gaetan Blandin
PSPaola Sepúlveda-Ruiz
Paola Sepúlveda-Ruiz
ATAntonina Torrens
Antonina Torrens
JHJordi Hernandez
Jordi Hernandez
IRIgnasi Rodríguez-Roda
Ignasi Rodríguez-Roda
Zoos are significant water consumers, exacerbating water scarcity challenges and impacting animal welfare. Despite the urgent need for effective water management in zoos, research on water saving remains limited. This study analyzes water consumption and potential of water saving strategies for animal welfare, using to Barcelona Zoo as a case study. Barcelona zoo’s historical water consumption averages 423,747 m 3 annually, equivalent to the daily water usage of approximately 10,554 people. Fluctuations in consumption are linked to renovations, rather than seasonal variations, due to the zoo’s effective water ponds renewal, cleaning procedures, and filtration systems. Water is mainly sourced from potable water (68% of total input), with seawater utilized in certain animal habitats, including for Spheniscus humboldti (Humboldt penguins) and Zalophus californianus (California sea lions). The animal ponds with the highest water consumption are Choeropsis liberiensis (Pygmy hippopotamus), Ursus arctos arctos (Eurasian brown bear), and Hippopotamus amphibius (Hippopotamus). While water consumption remains stable year-round, opportunities for water reuse, particularly in cleaning and filtration processes, are identified as critical for improving water efficiency. This study emphasizes the need for targeted water management strategies in zoos, emphasizing the importance of recycling wastewater, optimizing filtration systems, and exploring water conservation initiatives. The findings from Barcelona Zoo offer transferable sustainable water management practices for zoological and wildlife facilities, reducing demand and enhancing environmental sustainability.

3 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
Cinthia Estefania Padilla GallegosCinthia Estefania Padilla Gallegos
Cinthia Estefania Padilla Gallegos
IRIgnasi Rodríguez-Roda
Ignasi Rodríguez-Roda
GBGaetan Blandin
Gaetan Blandin
JFJoan Ferrer
Joan Ferrer
PSPaola Sepúlveda-Ruiz
Paola Sepúlveda-Ruiz
ATAntonina Torrens
Antonina Torrens
Water quality management in animal facilities is increasingly challenged by non-conventional wastewater matrices driven by heterogeneous enclosure designs and species-specific behaviors. This study evaluated sixteen animal ponds at Barcelona Zoo by integrating physicochemical, microbiological, and operational data using Multiple Factor Analysis (MFA) and Principal Component Analysis (PCA) combined with Hierarchical Clustering (HC). MFA explained 66% of variance, distinguishing open-exchange systems with high water renewal and consumption (>7,900 m³/year) from recirculated systems with low hydraulic turnover (<400 m³/year). PCA–HC revealed two dominant gradients: (i) organic matter accumulation and eutrophication potential (COD, BOD₅, TSS, PO₄³⁻), and (ii) nitrogen speciation, characterized by low NH₄⁺ and NO₃⁻ concentrations and predominance of organic nitrogen. Microbial profiles were strongly species- and system-specific, with flamingo and hippopotamus ponds exhibiting high fecal indicator loads, while reptile and bear systems were enriched in environmentally persistent proxies (Clostridium perfringens). Hierarchical clustering delineated risk-based operational groups, providing a framework to prioritize solids management, aeration, nitrogen-aware process design, and multi-barrier disinfection. Overall, the results demonstrate that enclosure-specific hydraulic and operational regimes, rather than absolute pollutant loads, govern water quality variability, and that multivariate clustering offers a transferable basis for risk-segmented management of non-conventional effluents. Future research should integrate quantitative microbial risk assessment (QMRA) and techno-economic analysis to align treatment strategies with health-based targets and sustainability objectives.

1 April 2025 in Journal of Environmental Engineering
Verified
Journal Article
Closed access
Cinthia Estefania Padilla GallegosCinthia Estefania Padilla Gallegos
Cinthia Estefania Padilla Gallegos
IRIgnasi Rodríguez-Roda
Ignasi Rodríguez-Roda
Gaetan BlandinGaetan Blandin
Gaetan Blandin

13 October 2026 in Applied Water Science
Verified
Journal Article
Open access
PDF file
Cinthia Estefania Padilla GallegosCinthia Estefania Padilla Gallegos
Cinthia Estefania Padilla Gallegos
IRIgnasi Rodríguez-Roda
Ignasi Rodríguez-Roda
Gaetan BlandinGaetan Blandin
Gaetan Blandin
JFJoan Ferrer-Vaquer
Joan Ferrer-Vaquer
PSPaola Sepúlveda-Ruiz
Paola Sepúlveda-Ruiz
ATAntonina Torrens
Antonina Torrens
Water quality management in animal facilities is increasingly challenged by non-conventional wastewater matrices, driven by heterogeneous enclosure designs and species-specific behaviors. Although zoo facilities are widespread and consume large volumes of water, very few studies have examined pond water quality, and even fewer have integrated physicochemical, microbiological, hydraulic, and operational variables in a single framework. This study evaluated sixteen animal ponds at Barcelona Zoo by integrating physicochemical, microbiological, and operational data using Multiple Factor Analysis (MFA) and Principal Component Analysis (PCA) combined with Hierarchical Clustering (HC), providing an exploratory approach for water quality assessment in heterogeneous aquatic systems. MFA explained 66% of variance, distinguishing open-exchange systems with high water renewal and consumption (> 7,900 m3/year) from recirculated systems with low hydraulic turnover (< 400 m3/year). PCA-HC revealed two dominant gradients: (i) organic matter accumulation and eutrophication potential (COD, BOD₅, TSS, PO₄3⁻), and (ii) nitrogen speciation, characterized by low NH₄⁺ and NO₃⁻ concentrations and a substantial fraction of total nitrogen not explained by the measured inorganic forms, contrasting with typical domestic wastewater. Microbial profiles were strongly species- and system-specific, with flamingo and hippopotamus ponds exhibiting high fecal indicator loads, while reptile and bear systems were enriched in environmentally persistent proxies (Clostridium perfringens). Hierarchical clustering identified exploratory operational groups based on water quality and enclosure characteristics, supporting comparative interpretation of site-specific management needs. Overall, the results indicate that enclosure-specific hydraulic and operational conditions were associated with distinct water quality patterns, suggesting that variability cannot be explained by pollutant loads alone. Consequently, this study provides an exploratory basis for tailored water management, prioritizing solids control, aeration, nitrogen transformation processes, and disinfection barriers in accordance with the identified cluster profiles. Future research should integrate quantitative microbial risk assessment (QMRA) and techno-economic analysis to align treatment strategies with health-based targets and sustainability objectives.

1 September 2026 in International Water Proceedings
Verified
Journal Article
Closed access
Cinthia Estefania Padilla GallegosCinthia Estefania Padilla Gallegos
Cinthia Estefania Padilla Gallegos
Gaetan BlandinGaetan Blandin
Gaetan Blandin
PSPaola Sepúlveda-Ruiz
Paola Sepúlveda-Ruiz
JHJ. Hernandez
J. Hernandez
AAA. Alarcon
A. Alarcon
IRIgnasi Rodríguez-Roda
Ignasi Rodríguez-Roda