Damilola Oluwafemi Samson

Dr. Damilola Oluwafemi Samson

Physics, University of Abuja, Abuja, Federal Capital Territory, Nigeria
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2020 in Radiation and Environmental Biophysics
Verified
Journal Article
Closed access
PDF file
Damilola Oluwafemi SamsonDamilola Oluwafemi Samson
Damilola Oluwafemi Samson
MJM. Z. Mat Jafri
M. Z. Mat Jafri
ASA. Shukri
A. Shukri
RHR. Hashim
R. Hashim
OSO. Sulaiman
O. Sulaiman
MYM. F. M. Yusof
M. F. M. Yusof

6 October 2023 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
MZMohd Aizuddin Zakaria
Mohd Aizuddin Zakaria
MRMohammad Khairul Azhar Abdul Razab
Mohammad Khairul Azhar Abdul Razab
MAMohd Zulfadli Adenan
Mohd Zulfadli Adenan
MAMuhammad Zabidi Ahmad
Muhammad Zabidi Ahmad
STSuffian Mohamad Tajudin
Suffian Mohamad Tajudin
MAMohd Zahri Abdul Aziz
Mohd Zahri Abdul Aziz

3 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Damilola Oluwafemi SamsonDamilola Oluwafemi Samson
Damilola Oluwafemi Samson
ASAhmad Shukri
Ahmad Shukri
NHNurul Ab. Aziz Hashikin
Nurul Ab. Aziz Hashikin
SZSiti Hajar Zuber
Siti Hajar Zuber
MAMohd Zahri Abdul Aziz
Mohd Zahri Abdul Aziz
SGSylvester Jande Gemanam
Sylvester Jande Gemanam
Background: Different compositions of DSF/NaOH/IA-PAE/R. spp. composite particleboard phantoms were constructed. Methods: Photon attenuation characteristics were ascertained using gamma rays from 137Cs and 60Co. Absorbed doses at the location of an ionization chamber and Gafchromic EBT3 radiochromic films were calculated for high-energy photons (6 and 10 MV) and electrons (6, 9, 12, and 15 MeV). Results: The calculated TPR20,10 values indicate that the percentage discrepancy for 6 and 10 MV was in the range of 0.29–0.72% and 0.26–0.65%. It was also found that the relative difference in the dmax to water and solid water phantoms was between 1.08–1.28% and 5.42–6.70%. The discrepancies in the determination of PDD curves with 6, 9, 12, and 15 MeV, and those of water and solid water phantoms, ranged from 2.40–4.84%. Comparable results were found using the EBT3 films with variations of 2.0–7.0% for 6 and 10 MV photons. Likewise, the discrepancies for 6, 9, 12, and 15 MeV electrons were within an acceptable range of 2.0–4.5%. Conclusions: On the basis of these findings, the DSF/NaOH/IA-PAE/R. spp. particleboard phantoms with 15 wt% IA-PAE addition level can be effectively used as alternative tissue-equivalent phantom material for radiation therapy applications.

23 April 2026 in Radiation Oncology
Verified
Journal Article
Open access
Damilola Oluwafemi SamsonDamilola Oluwafemi Samson
Damilola Oluwafemi Samson
MIMahayu Ismail
Mahayu Ismail
MHMohd Ariff Mohamed Hanifa
Mohd Ariff Mohamed Hanifa
EMEznal Izwadi Mohd Mahidin
Eznal Izwadi Mohd Mahidin
HMHanani Abdul Manan
Hanani Abdul Manan
NYNoorazrul Yahya
Noorazrul Yahya
Radiation-induced xerostomia (RIXM) remains a common toxicity in head-and-neck cancer (HNC) patients receiving radiotherapy, with currently used static dosimetric models exhibiting limited predictive accuracy. This study evaluates delta-radiomics from longitudinal VMAT-CBCT imaging, combined with explainable machine learning classifiers (MLCs), to capture treatment-related changes in the parotid gland across seven weeks and improve RIXM prediction. A retrospective cohort of 131 HNC patients (101 males, 30 females; aged 23–87) treated with VMAT-based chemoradiotherapy (60–70 Gy over 6–7 weeks) from 2020 to 2023 was analyzed. RIXM was graded using CTCAE v5.0 at 3, 6, and 12-months post-treatment, representing early, intermediate, and late endpoints. Radiomic features were extracted from weekly CBCT-derived parotid segmentations (6–7 per patient) following IBSI guidelines, and delta-radiomics was computed across multiple preprocessing pipelines. The dataset was split into training/validation (n = 91; 69.5%) and testing (n = 40; 30.5%) sets using stratified patient-level splitting. A hybrid feature selection method combining univariate filtering and recursive feature elimination with cross-validation was applied, followed by SMOTE. Seven MLCs and a dosimetric NTCP model were developed using Python (v7.0.8, scikit-learn). Model interpretability was assessed with SHAP; feature significance and predictive performance were evaluated using paired t-tests, PPV, and NPV. Early, intermediate, and late RIXM occurred in 90.8% (3-months), 91.6% (6-months), and 77.1% (12-months) of patients, respectively. The strongest predictions were found for week-4 and 6-month endpoint. SVM achieved the highest predictive performance (AUC: 0.79 ± 0.01, 95% CI: 0.65–0.83; PR-AUC: 0.98; sensitivity: 0.92, CI: 0.90–0.92; specificity: 0.69, CI: 0.67–0.70; F1-score: 0.90 ± 0.01; BAcc: 0.81; MCC: 0.51; Brier score: 0.11 ± 0.01), with balanced PPV (0.81 ± 0.04) and NPV (0.64 ± 0.02). Similar results were observed with the NTCP model (AUC: 0.82 ± 0.01, 95% CI: 0.67–0.89; PR-AUC: 0.97; sensitivity: 1.00, CI: 0.96–1.00; specificity: 0.72, CI: 0.72–0.74; F1-score: 0.92 ± 0.01) and calibration (BAcc: 0.86; MCC: 0.48; Brier score: 0.08 ± 0.01; PPV: 0.83 ± 0.01; NPV: 0.67 ± 0.02). SHAP analysis identified comorbidities (mean: 1.204; p: 0.007), delta-radiomic features (strength-(IBSI:1 X9X) (mean: 1.179; p: 0.041), histogram gradient-(IBSI: RHQZ) (mean: 1.021; p: 0.043), intensity kurtosis-(IBSI: C317) (mean: 0.592; p: 0.045)), and DmeanRT_PG (mean: 0.447; p: 0.045), as significant predictors of RIXM. Delta-radiomics combined with explainable classifiers accurately predicted RIXM at 3, 6, and 12-months post-treatment. Week-4 and 6-month features were most predictive, supporting early, personalized, dose-informed radiotherapy interventions. The online version contains supplementary material available at 10.1186/s13014-026-02846-5.

14 March 2021 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
Damilola Oluwafemi SamsonDamilola Oluwafemi Samson
Damilola Oluwafemi Samson
ASAhmad Shukri
Ahmad Shukri
MMMohd Zubir Matjafri
Mohd Zubir Matjafri
RHRokiah Hashim
Rokiah Hashim
MAMohd Zahri Abdul Aziz
Mohd Zahri Abdul Aziz
MYMohd Fahmi Mohd Yusof
Mohd Fahmi Mohd Yusof

23 February 2023 in Health Physics
Verified
Journal Article
Closed access
Damilola Oluwafemi SamsonDamilola Oluwafemi Samson
Damilola Oluwafemi Samson
MAMohd Zahri Abdul Aziz
Mohd Zahri Abdul Aziz
ASAhmad Shukri
Ahmad Shukri
MJMohd Zubir Mat Jafri
Mohd Zubir Mat Jafri
RHRokiah Hashim
Rokiah Hashim
MYMohd Fahmi Mohd Yusof
Mohd Fahmi Mohd Yusof
The current study was undertaken to investigate the radiological and dosimetric parameters of natural product-based composite (SPI/NaOH/IA-PAE/Rhizophora spp.) phantoms. The radiological properties of the phantoms were measured at different gamma energies from Compton scatter of photons through angles of 0, 30, 45, 60, 75, and 90 degrees. Ionization chamber (IC) and Gafchromic EBT3 film dosimeters were employed to evaluate the dosimetric characteristics for photons (6–10 MV) and electrons (6–15 MeV). Radiological property results of the composite phantoms were consistent with good quality compared to those of solid water phantoms and theoretical values of water. Photon beam quality index of the SPI15 phantom with p-values of 0.071 and 0.073 exhibited insignificant changes. In addition, good agreement was found between PDD curves measured with IC and Gafchromic EBT3 film for both photons and electrons. The computed therapeutic and half-value depth ranges matched within the limits and are similar to those of water and solid water phantoms. Therefore, the radiological and dosimetric parameters of the studied composite phantom permit its use in the selection of convenient tissue- and water-equivalent phantom material for medical applications.