Dan Wills

Dr. Dan Wills

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Biomaterials
Verified
Journal Article
Closed access
CKCambre N. Kelly
Cambre N. Kelly
TWTian Wang
Tian Wang
JCJames Crowley
James Crowley
DWDan Wills
Dan Wills
MPMatthew Henry Pelletier
Matthew Henry Pelletier
WWWilliam Walsh
William Walsh

1 November 2021 in The Spine Journal
Verified
Journal Article
Open access
JCJordan C. Conway
Jordan C. Conway
RORema A. Oliver
Rema A. Oliver
TWTian Wang
Tian Wang
DWDan Wills
Dan Wills
JHJoe Herbert
Joe Herbert
IGIain R. Gibson
Iain R. Gibson
Synthetic bone graft substitutes are commonly used in spinal fusion surgery. Preclinical data in a model of spinal fusion to support their efficacy is an important component in clinical adoption to understand how these materials provide a biological and mechanical role in spinal fusion. To evaluate the in vivo response of a nanosynthetic silicated calcium phosphate putty (OstP) combined with autograft compared to autograft alone or a collagen-biphasic calcium phosphate putty (MasP) combined with autograft in a rabbit spinal fusion model. Efficacy of a nanosynthetic silicated calcium phosphate putty as an extender to autograft was studied in an experimental animal model of posterolateral spinal fusion at 6, 9, 12 and 26 weeks, compared to a predicate device. Skeletally mature female New Zealand White rabbits (70) underwent single level bilateral posterolateral intertransverse process lumbar fusion, using either autograft alone (AG), a nanosynthetic silicated calcium phosphate putty (OstP) combined with autograft (1:1), or a collagen-biphasic calcium phosphate putty (MasP) combined with autograft (1:1). Iliac crest autograft was harvested for each group, and a total of 2 cc of graft material was implanted in the posterolateral gutters per side. Fusion success was assessed at all time points by manual palpation, radiographic assessment, micro-CT and at 12 weeks only using non-destructive range of motion testing. Tissue response, bone formation and graft resorption were assessed by decalcified paraffin histology and by histomorphometry of PMMA embedded sections. Assessment of fusion by manual palpation at the 12 week endpoint showed 7 out of 8 (87.5%) bilateral fusions in the OstP extender group, 4 out of 8 (50%) fusions in the MasP extender group, and 6 out of 8 (75%) fusions in the autograft alone group. Similar trends were observed with fusion scores of radiographic and micro-CT data. Histology showed a normal healing response in all groups, and increased bone formation in the OstP extender group at all timepoints compared to the MasP extender group. New bone formed directly on the OstP granule surface within the fusion mass while this was not a feature of the Collagen-Biphasic CaP material. After 26 weeks the OstP extender group exhibited 100% fusions (5 out of 5) by all measures, whereas the MasP extender group resulted in bilateral fusions in 3 out of 5 (60%), assessed by manual palpation, and fusion of only 20 and 0% by radiograph and micro-CT scoring, respectively. Histology at 26 weeks showed consistent bridging of bone between the transverse processes in the Ost P extender group, but this was not observed in the MasP extender group. The nanosynthetic bone graft substituted studied here, used as an extender to autograft, showed a progression to fusion between 6 and 12 weeks that was similar to that observed with autograft alone, and showed excellent fusion outcomes, bone formation and graft resorption at 26 weeks. This preclinical study showed that the novel nanosynthetic silicated CaP putty, when combined with autograft, achieved equivalent fusion outcomes to autograft. The development of synthetic bone grafts that demonstrate efficacy in such models can eliminate the need for excessive autograft harvest and results from this preclinical study supports their effective use in spinal fusion surgery.

2 May 2023 in Veterinary and Comparative Orthopaedics and Traumatology
Verified
Journal Article
Closed access
PDF file
LFLucy M. Fuchter
Lucy M. Fuchter
DWDan Wills
Dan Wills
WWWilliam Walsh
William Walsh
MNMark Newman
Mark Newman
CTChris Tan
Chris Tan
Objective The aim of this study was to compare the interfragmentary compressive force and area of compression generated by cortical screws inserted as either a lag screw or position screw in simulated lateral humeral condylar fractures. Study Design Ex vivo biomechanical study. Materials and Methods Thirteen pairs of cadaveric humeri from skeletally mature Merinos with simulated lateral humeral condylar fractures were used. Pressure sensitive film was inserted into the interfragmentary interface prior to fracture reduction with fragment forceps. A cortical screw was inserted as a lag screw or a position screw and tightened to 1.8Nm. Interfragmentary compression and area of compression were quantified and compared between the two treatments groups at three time points. Results After fracture reduction using fragment forceps (Time point 1: T1), there was no significant difference in interfragmentary compression and area of compression between the two treatments. A combination of fragment forceps and a cortical screw inserted as a lag screw (Time point 2: T2) produced significantly greater interfragmentary compression and area of compression compared with the same screw inserted as a positional screw. After removal of the fragment forceps, leaving only the cortical screw (Time point 3: T3), both the interfragmentary compression and area of compression remain significantly greater in the lag screw group. Conclusion Lag screws generate a greater force of compression and area of compression compared with position screws in this mature ovine humeral condylar fracture model.

1 November 2020 in The Spine Journal
Verified
Journal Article
Open access
WWWilliam Walsh
William Walsh
MPMatthew Henry Pelletier
Matthew Henry Pelletier
DWDan Wills
Dan Wills
TWTian Wang
Tian Wang
SBShaeffer Bannigan
Shaeffer Bannigan
FVFrank Vizesi
Frank Vizesi
The interface and interactions between an interbody cage, graft material and host bone can all participate in the fusion. Shortcomings of PEEK interbody cages have been addressed with novel titanium surfaces. Titanium surfaces paired with macro-scale topography features on the endplates and within the aperture may provide additional benefits. To evaluate the influence of cage design parameters on interbody fusion in a large animal pre-clinical model. A comparative preclinical large animal model was performed to evaluate how macroscale topography features of an interbody cage can facilitate early integration between the host bone, graft material, and interbody cage and these effects on biomechanical stability and fusion. Forty single level interbody fusions (L4-5) using iliac crest autograft and bilateral pedicle screw fixation were performed in adult sheep to evaluate the effect of undercut macrostructure topography features of an interbody cage on the endplates and within the aperture. Fusions were evaluated at 6 and 12 weeks (n=10 per group) using radiography, microcomputed tomography, biomechanical integrity and histology endpoints. The presence of the undercut macrostructures present on the endplates and within the aperture statistically improved biomechanical integrity at 6 and 12 weeks compared to controls. Microcomputed tomography and histology demonstrated bony interdigitation within the endplate and aperture features contributing to the improvement in properties. The current study demonstrates that PEEK implants with titanium surfaces can be augmented by undercut macrostructures present on the endplates and within the aperture to provide opportunities for a series of anchoring points that, with new bone formation and remodelling, result in earlier and improved biomechanical integrity of the treated level. This preclinical study showed that bone interdigitation with the undercut macrostructures present on the endplates and within the aperture resulted in improved fusion and biomechanical stability in a clinically relevant spinal fusion model. Future clinical study is warranted to evaluate such implants' performance in humans.

9 December 2024 in The Spine Journal
Verified
Journal Article
Open access
JLJeremy A. Lombardo
Jeremy A. Lombardo
DWDan Wills
Dan Wills
TWTian Wang
Tian Wang
MPMatthew Henry Pelletier
Matthew Henry Pelletier
SFS. Harrison Farber
S. Harrison Farber
WWWilliam R. Walsh
William R. Walsh
3D-printed titanium cage designs can incorporate complex, porous features for bone ingrowth and a greater surface area for minimizing subsidence. In a companion study (Part 1), we determined that increased surface area leads to decreased subsidence; however, it remains unclear how increasing the cage surface area, resulting in a smaller graft aperture, influences fusion. We evaluated the effects of surface area of 3D-printed titanium cages and the use of autologous bone grafts on spinal fusion in sheep. In vivo large animal study in 12 sheep. Interbody fusion was performed in 12 adult sheep at 24 levels (L2-3 and L4-5) using 3D-printed titanium cages with bilateral pedicle screw fixation. The cage designs varied in aperture: standard (low endplate surface area), small (medium endplate surface area), or none (high endplate surface area). These cages were packed with autologous iliac crest bone grafts (ICBG). A fourth group was implanted without bone grafts, using the no-aperture cage. Fusion was evaluated at 16 weeks via manual palpation, microcomputed tomography (microCT), histology, and histomorphometry. Standard, small, and no-aperture cages packed with ICBG resulted in high fusion rates (80%, 100%, and 83%, respectively) at 16 weeks by manual palpation, and these results were not significantly different. Implantation without ICBG was associated with a significantly lower fusion rate (33%, p<.05). Histological, histomorphometry, and microCT results supported the findings obtained by manual palpation; findings from these modalities showed new bone spanning the vertebral endplates in the spines graded as fused by manual palpation. Similar fusion results for standard, small, and no-aperture cage designs packed with ICBG suggest that aperture size does not influence fusion results in the sheep model. However, without ICBG grafting, fusion was significantly decreased, suggesting that graft material is necessary to predictably obtain fusion in this model. When the in vitro subsidence data (companion study, Part 1) is considered with the in vivo fusion data described here, porous 3D-printed titanium cages with maximal surface endplate contact and bone grafting perform favorably, resulting in low subsidence and high fusion rates. 3D-printed porous titanium interbody cages are novel devices with increasing clinical use. The study results show that the aperture size of the interbody cage did not influence fusion in a large animal (sheep) model. The use of bone graft material was the most important variable affecting fusion. These data suggest that the clinical use of 3D Ti cages without graft material should be avoided.

11 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
RBRuggero Belluomo
Ruggero Belluomo
IAInazio Arriola-Alvarez
Inazio Arriola-Alvarez
NKNathan W. Kucko
Nathan W. Kucko
WWWilliam Walsh
William Walsh
JBJoost D. de Bruijn
Joost D. de Bruijn
FGFlorence Barrère-de Groot
Florence Barrère-de Groot
A biphasic calcium phosphate with submicron needle-shaped surface topography combined with a novel polyethylene glycol/polylactic acid triblock copolymer binder (BCP-EP) was investigated in this study. This study aims to evaluate the composition, degradation mechanism and bioactivity of BCP-EP in vitro, and its in vivo performance as an autograft bone graft (ABG) extender in a rabbit Posterolateral Fusion (PLF) model. The characterization of BCP-EP and its in vitro degradation products showed that the binder hydrolyses rapidly into lactic acid, lactide oligomers and unaltered PEG (polyethylene glycol) without altering the BCP granules and their characteristic submicron needle-shaped surface topography. The bioactivity of BCP-EP after immersion in SBF revealed a progressive surface mineralization. In vivo, BCP-EP was assessed in a rabbit PLF model by radiography, manual palpation, histology and histomorphometry up to 12 weeks post-implantation. Twenty skeletally mature New Zealand (NZ) White Rabbits underwent single-level intertransverse process PLF surgery at L4/5 using (1) autologous bone graft (ABG) alone or (2) by mixing in a 1:1 ratio with BCP-EP (BCP-EP/ABG). After 3 days of implantation, histology showed the BCP granules were in direct contact with tissues and cells. After 12 weeks, material resorption and mature bone formation were observed, which resulted in solid fusion between the two transverse processes, following all assessment methods. BCP-EP/ABG showed comparable fusion rates with ABG at 12 weeks, and no graft migration or adverse reaction were noted at the implantation site nor in distant organs.