The random nature of renewable sources causes power fluctuations affecting the stability in the utility grid. This problem has motivated the development of new power smoothing techniques using supercapacitors and batteries. However, experimental studies based on multiple renewable sources (photovoltaic, wind, hydrokinetic) that demonstrate the validity of power smoothing techniques under real conditions still require further study. For this reason, this article presents a feasibility study of a renewable grid-connected system, addressing various aspects based on power quality and energy management. The first of them is related to the fluctuations produced by the stochastic characteristics of renewable sources and demand. Two power smoothing algorithms are presented (ramp rate and moving average) combining photovoltaic, wind, and hydrokinetic sources with a hybrid storage system composed of supercapacitors and lithium-ion batteries. Then, the self-consumption for an industrial load is analyzed by studying the energy flows between the hybrid renewable energy sources and the grid. The main novelty of this paper is the operability of the supercapacitor. The experimental results show that when applying the power smoothing ramp rate method, the supercapacitor operates fewer cycles with respect to the moving average method. This result is maintained by varying the capacity of the renewable sources. Moreover, by increasing the capacity of photovoltaic and wind renewable sources, the hybrid storage system requires a greater capacity only of supercapacitors, while by increasing the capacity of hydrokinetic turbines, the battery requirement increases considerably. Finally, the cost of energy and self-consumption reach maximum values by increasing the capacity of the hydrokinetic turbines and batteries.
The power generated by photovoltaic solar systems is exposed to high variability of irradiance mainly due to weather conditions, which cause instability in the electrical networks connected to these systems. This study shows the typical behavior of solar irradiance in an Andean city, which presents considerable variations that can reach up to 63% of the nominal power of the photovoltaic system, at time intervals in the order of seconds. The study covers the application of 3 techniques to reduce power fluctuations at the point of common coupling (PCC), with the incorporation of energy storage systems, under the same irradiance conditions. Supercapacitors were used as the storage system, which were selected for their high efficiency and useful life. A state of charge control is also applied by means of a hysteresis band. The three algorithms studied show similar behaviors; however, the ramp control technique has the best performance. The storage system was dimensioned based on the photovoltaic system’s nominal power and the desired rate of change in the PCC, whose capacity can be estimated from Pnom/12 [kWh] and a maximum power that can reach up to 0.63 Pnom. The study determines that based on the storage capacity and the irradiance characteristics under study, the storage system could use at least 5.76 daily charge/discharge cycles. In the study, it is possible to reduce the rate of change of the photovoltaic energy injected into the PCC about 6.66 times with the use of the proposed energy storage system.