In recent years, earthquakes have caused more damage to nonstructural components, such as mechanical and electrical equipment and piping systems, than to structural components. In particular, among the nonstructural components, the electrical cabinet is an essential piece of equipment used to maintain the functionality of critical facilities such as nuclear and non-nuclear power plants. Therefore, damage to the electrical cabinet associated with the safety of the facility can lead to severe accidents related to loss-of-life and property damage. Consequently, the electrical cabinet system must be protected against strong ground motion. This paper presents an exploratory study of dynamic characteristics of seismically isolated remote terminal unit (RTU) cabinet system subjected to tri-axial shaking table, and also the shaking table test of the non-seismically isolated cabinet system was conducted to compare the vibration characteristics with the cabinet system installed with friction pendulum isolator device. In addition, for the shaking table test, two recorded earthquakes obtained from Korea and artificial earthquakes based on the common application of building seismic-resistant design standards as an input ground motions were applied. The experimental assessment showed that the various damage modes such as door opening, the fall of the wire mold, and damage to door lock occurred in the RTU panel fixed on the concrete foundation by a set anchor, but the damage occurred only at the seismic isolator in the seismically isolated RTU panel system. Furthermore, it was considered that the application of the seismic isolator can effectively mitigate the impact and amplification of seismic force to the RTU panel system during and after strong ground motions in this study.
20 February 2019 in Transactions of the Korean Society for Noise and Vibration Engineering
In this study, a shaking table test was performed to analyze the anchor behavior with or without rocking in the base plate of an electric cabinet. Two cabinets, differentiated by whether their base plates were anchored or fixed, were mounted simultaneously on a shaking table to enable a comparison of their behavior when subjected to seismic motion. Three seismic waves were used in this experiment to facilitate temporal history and resonance search. Results indicated that the impact load occurred due to mutual collision with the local mode of the cabinets’ internal components. Moreover, in the case of a single-door cabinet with a bolt fastening, it was observed that rocking mode occurred due to upliftment of the base plate. To address this problem the cabinet was tested again after being reinforced and the results achieved before and after the reinforcement procedure were discussed.
Piping systems are a representative social infrastructure to provide oil, gas, and water. Damage to piping systems may cause serious consequences, such as fire, water outage, and environmental pollution. Therefore, piping systems need to be protected from natural disasters, such as earthquakes. Earthquakes may cause deformation that exceeds piping design criteria. For example, large relative displacements and liquefaction of the ground resulting in loss of strength and ground subsidence, and the side-sway of primary structures subjected to a strong ground motion may cause critical damage to piping systems. Therefore, expansion joints to maintain flexibility can be applied to locations where excessive deformation is expected to improve the seismic performance of piping systems. Metal bellows, a type of expansion joints, are flexible, so they are highly durable against deformation and fatigue loads. This indicates that metal bellows can be used as seismic separation joints for piping. In this study, experimental research was conducted to analyze the seismic performance of multi-ply bellows type expansion joints, a type of metal bellows. Monotonic loading tests and cyclic loading tests were conducted on 2-ply bellows and 3-ply bellows, and the results were compared. In the cyclic loading tests, multi-step increasing amplitude cyclic loading, which used the displacement history amplified in stages, and constant amplitude cycling loading with various magnitudes were considered. The test results showed no significant difference in bending performance for monotonic loading between the two types of multi-ply bellows. The 3-ply bellows, however, showed higher performance for low-cycle fatigue than 2-ply bellows.
An isolation system installed in a nuclear power plant (NPP) could increase seismic safety during seismic events. On the other hand, a more significant relative displacement may occur due to the isolation system. The seismic risk could be increased in the case of an interface piping system that connects isolated and nonisolated structures. Therefore, it is necessary to consider the piping systems when evaluating the safety of isolated-NPPs. This study performed seismic fragility analysis with isolated APR1400 nuclear power plants with the main steam piping. The main steam piping is the interface pipe connecting the isolated auxiliary building and the turbine building. The failure mode for seismic fragility analysis was defined as cracks caused by leakage. The experimental and numerical analysis results quantified the leak-through crack point as a damage index. The seismic fragility curves are suggested based on peak ground acceleration and the relative displacement between the isolated and nonisolated buildings.
Numerical model updating using the data measured from the actual structure is required in order to minimize the error between the initial numerical model and the actual structure. Field load tests, which are conducted in order to assess the condition and safety of high-speed railway bridges, are generally expensive and restricted by railway control and weather conditions. Therefore, a method for evaluating the performance of high-speed railway bridges using updated numerical models without conducting field load tests is required. In this study, numerical model updating was performed by using the data measured from the ambient vibration test in order to assess the dynamic stability of high-speed railway bridges. In the ambient vibration test, the measurement point roaming method was applied in order to accurately measure high-speed railway bridges using a limited number of sensors. For numerical model updating, the univariate search method was used, and several measured parameters were updated and converted into the properties of the target bridges in the numerical models. The vertical and torsional modes of the updated numerical models differed by less than 5% from those estimated using the data measured from the target bridges. The responses of the updated numerical models were found to be similar to those measured from the high-speed railway bridges in operation. It was also shown that the updated numerical models could be used to assess the dynamic stability of the bridges.
Accurately calculating the vehicle load acting on a bridge at any one time is crucial to determining the integrity and safety of the bridge. To ensure this integrity and safety, information on the types, characteristics, and load of vehicles that regularly cross the bridge is very important in terms of its structural adequacy and maintenance. In this study, the vehicle load that a bridge will be subjected to was estimated using the reaction force response at the support. To estimate this response to the reaction force, a vertical displacement sensor, developed based on Fiber Bragg Grating (FBG), was applied to the Eradi Quake System (EQS), a commercially available bridge bearing. This vertical displacement sensor can measure the vertical load and has the advantage of being easy to attach and detach. To verify the performance and accuracy of this sensor, this study conducted numerical analysis and vehicle loading tests. It found that the vehicle load can be estimated from the reaction force response, as measured by the vertical displacement sensor on the bridge.