Guozhe Deng

Dr. Guozhe Deng

Southeast University, Nanjing 210096, Jiangsu, China
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2013 in Analytical Chemistry
Verified
Journal Article
Closed access
Guozhe DengGuozhe Deng
Guozhe Deng
KXKun Xu
Kun Xu
YSYue Sun
Yue Sun
YCYu Chen
Yu Chen
TZTiesong Zheng
Tiesong Zheng
JLJianlin Li
Jianlin Li

1 August 2019 in European Journal of Pharmacology
Verified
Journal Article
Closed access
MJMinzi Ju
Minzi Ju
YLYaqun Liu
Yaqun Liu
MLMingyue Li
Mingyue Li
MCMengjing Cheng
Mengjing Cheng
YZYuan Zhang
Yuan Zhang
HLHua Liu
Hua Liu

1 February 2019 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
CGChirag Godiya
Chirag Godiya
XCXiao Cheng
Xiao Cheng
Guozhe DengGuozhe Deng
Guozhe Deng
DLDawei Li
Dawei Li
XLXiaolin Lu
Xiaolin Lu

1 February 2011 in Thin Solid Films
Verified
Journal Article
Closed access
NWN.N. Wei
N.N. Wei
THT. Han
T. Han
Guozhe DengGuozhe Deng
Guozhe Deng
JLJ.L. Li
J.L. Li
JDJ.Y. Du
J.Y. Du


11 November 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Guozhe DengGuozhe Deng
Guozhe Deng
LXLi Xie
Li Xie
SXShengjia Xu
Shengjia Xu
XKXuejun Kang
Xuejun Kang
JMJizheng Ma
Jizheng Ma
Short-chain fatty acids (SCFAs) are among the active metabolites in biological process both in the intestinal tract and the bioconversion of organic wastes, which has resulted in various human diseases and environmental problems. In order to accurately detect SCFAs, we introduced a novel extraction sorbent. Electrospun polyacrylonitrile (PAN) nanofiber membrane was synthesized, then poly (3, 4-Ethylenedioxythiophene) (PEDOT) was deposited onto the surface of electrospun PAN nanofibers by in situ polymerization. The morphology of the composite PAN/PEDOT nanofiber was characterized by scanning electronic microscopy (SEM) and FTIR spectrum. PAN/PEDOT was used to isolate and concentrate the SCFAs in waste water and fecal samples before gas chromatography mass spectrometry (GC-MS) analysis. The analytical method was evaluated systematically, and low limits of detection (LODs) of 0.34–0.87 μg/L and good linearity (R2 ≥ 0.9953) were obtained. The method was applied successfully for the determination of SCFAs in waste water and fecal samples, with good recovery (87.5–104.6%) and satisfactory reproducibility (relative standard deviation: 6.5–14.1%). The results indicated that the proposed method can be used as a potential approach for the determination of SCFAs with high sensitivity in waste water and biological samples.