Diana D'agostino

Dr. Diana D'agostino

University of Naples "Federico II", Department of Industrial Engineering
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Renewable Energy
Verified
Journal Article
Closed access
Fabrizio AscioneFabrizio Ascione
Fabrizio Ascione
Diana D'agostinoDiana D'agostino
Diana D'agostino
CMConcetta Marino
Concetta Marino
FMFrancesco Minichiello
Francesco Minichiello

6 February 2024 in Renewable Energy
Verified
Journal Article
Open access
Federico MinelliFederico Minelli
Federico Minelli
ICIlaria Ciriello
Ilaria Ciriello
Francesco MinichielloFrancesco Minichiello
Francesco Minichiello
Diana D'agostinoDiana D'agostino
Diana D'agostino

1 July 2019 in Journal of Building Engineering
Verified
Journal Article
Closed access
Diana D'agostinoDiana D'agostino
Diana D'agostino
FRFilippo De’ Rossi
Filippo De’ Rossi
MMMarcello Marigliano
Marcello Marigliano
CMConcetta Marino
Concetta Marino
FMFrancesco Minichiello
Francesco Minichiello

1 May 2021 in Energy and Buildings
Verified
Journal Article
Closed access
Diana D'agostinoDiana D'agostino
Diana D'agostino
PDPierpaolo D'AGostino
Pierpaolo D'AGostino
FMFederico Minelli
Federico Minelli
FMFrancesco Minichiello
Francesco Minichiello

3 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
Diana D'agostinoDiana D'agostino
Diana D'agostino
LMLuigi Mele
Luigi Mele
Francesco MinichielloFrancesco Minichiello
Francesco Minichiello
Carlo RennoCarlo Renno
Carlo Renno
Currently, ground source heat pump (GSHP) technology is being studied, as the use of the ground as a source of renewable energy allows significant energy savings to be obtained. Therefore, it is useful to quantify how these savings help to achieve the energy balance of a Net Zero Energy Building (NZEB) compared to an air source heat pump or a condensing boiler coupled to a chiller. This paper assesses how these savings affect the number of photovoltaic panels installed on the roof of a building to obtain the NZEB target. The study is conducted by dynamic simulation for a building used as a bed and breakfast, virtually placed in two Italian towns. The energy savings and reduction of CO2 emissions, the percentage of renewable energy used, and the photovoltaic surface needed are assessed. Finally, the discounted payback period is calculated. The results show that the GSHP, unlike the systems to which it is compared, allows an NZEB to be obtained by balancing yearly energy consumption with energy production systems which only use on-site renewable energy sources (by exploiting the surface available on the roof) for both of the climatic conditions considered. GSHP also allows primary energy requests equal to or less than 57 kWh/m2 to be obtained.

5 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
Diana D'agostinoDiana D'agostino
Diana D'agostino
FEFrancesco Esposito
Francesco Esposito
Adriana GrecoAdriana Greco
Adriana Greco
Claudia MasselliClaudia Masselli
Claudia Masselli
Francesco MinichielloFrancesco Minichiello
Francesco Minichiello
In this paper the energy performances carried out by an investigation conducted on a Heating, Ventilation and Air Conditioning (HVAC) system, composed by an Air Handling Unit (AHU) for the primary air coupled with a horizontal-pipes Ground-to-Air Heat eXchanger (GAHX) and fan-coil units, for an office building, supposed to be placed in four different cities (Rio de Janeiro, Dubai, Naples, Ottawa) belonging to four different worldwide climatic areas, according to the Köppen climate classification. The investigation is performed by means of a two dimensional numerical model, experimentally validated, of an GAHX solved with finite element method. The results introduced in this paper are carried out by varying the length of the pipes and the air flow velocity; thus, also the number of tubes forming the GAHX is varied since the volumetric flow rate to be provided to the AHU must be kept constant. The energy performances of the above-mentioned HVAC system are analyzed, both in summer and in winter operation modes. Specifically, the reduction of the power of the heating and cooling coils in the AHU due to the pre-treatment of the air operated by the GAHX, the efficiency of the GAHX and the inlet-outlet temperature span are evaluated through a sensitivity analysis. These results lead to say that an GAHX for the geothermal pre-treatment of the air to be introduced into the AHU is energetically very convenient since it leads total thermal power savings in all the investigated cities, that makes this solution competitive. Specifically the best value of power reduction (61.5%) for a 100 m pipe-length GAHX is obtained in Ottawa, a city belonging to continental climate zone. The worst results in terms of power reduction are registered in Rio de Janeiro, a city belonging to the tropical or equatorial climates: this reduction, for a 100 m pipe-length ground to air heat exchanger, is 23.9%.