Norbert Dillier

Prof. Dr. Norbert Dillier

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2017 in Brain Structure and Function
Verified
Journal Article
Closed access
PDF file
NGNathalie Giroud
Nathalie Giroud
SHSarah Hirsiger
Sarah Hirsiger
RMRaphaela Muri
Raphaela Muri
AKAndrea Kegel
Andrea Kegel
Norbert DillierNorbert Dillier
Norbert Dillier
MMMartin Meyer
Martin Meyer

7 October 2015 in Audiology Research
Verified
Journal Article
Open access
PDF file
Norbert DillierNorbert Dillier
Norbert Dillier
WLWai Kong Lai
Wai Kong Lai
The Nucleus® 5 System Sound Processor (CP810, Cochlear™, Macquarie University, NSW, Australia) contains two omnidirectional microphones. They can be configured as a fixed directional microphone combination (called Zoom) or as an adaptive beamformer (called Beam), which adjusts the directivity continuously to maximally reduce the interfering noise. Initial evaluation studies with the CP810 had compared performance and usability of the new processor in comparison with the Freedom™ Sound Processor (Cochlear™) for speech in quiet and noise for a subset of the processing options. This study compares the two processing options suggested to be used in noisy environments, Zoom and Beam, for various sound field conditions using a standardized speech in noise matrix test (Oldenburg sentences test). Nine German-speaking subjects who previously had been using the Freedom speech processor and subsequently were upgraded to the CP810 device participated in this series of additional evaluation tests. The speech reception threshold (SRT for 50% speech intelligibility in noise) was determined using sentences presented via loudspeaker at 65 dB SPL in front of the listener and noise presented either via the same loudspeaker (S0N0) or at 90 degrees at either the ear with the sound processor (S0NCI+) or the opposite unaided ear (S0NCI-). The fourth noise condition consisted of three uncorrelated noise sources placed at 90, 180 and 270 degrees. The noise level was adjusted through an adaptive procedure to yield a signal to noise ratio where 50% of the words in the sentences were correctly understood. In spatially separated speech and noise conditions both Zoom and Beam could improve the SRT significantly. For single noise sources, either ipsilateral or contralateral to the cochlear implant sound processor, average improvements with Beam of 12.9 and 7.9 dB in SRT were found. The average SRT of –8 dB for Beam in the diffuse noise condition (uncorrelated noise from both sides and back) is truly remarkable and comparable to the performance of normal hearing listeners in the same test environment. The static directivity (Zoom) option in the diffuse noise condition still provides a significant benefit of 5.9 dB in comparison with the standard omnidirectional microphone setting. These results indicate that CI recipients may improve their speech recognition in noisy environments significantly using these directional microphone-processing options.

1 January 2009 in Cochlear Implants International
Verified
Journal Article
Closed access
WLWaikong Lai
Waikong Lai
Norbert DillierNorbert Dillier
Norbert Dillier
The electrically evoked compound action potential (ECAP) amplitude resulting from a train of pulses of finite duration (100 ms or 200 ms) was found to vary inversely to the stimulation rate (pulse rate), corroborating well with neural adaptation results from a previous study (Dillier et al., 2005). Amplitude growth functions based on these adapted responses yield thresholds (TNRT) that increase with increasing pulse rate, contrary to behavioural thresholds, which are known to vary inversely with the stimulation rate. Adaptation effects are therefore a confounding factor that must be accounted for when attempting to compare behavioural and objective measures.

14 January 2021 in Journal of the Audio Engineering Society
Verified
Journal Article
Closed access
PDF file
LSLaurent S. R. Simon
Laurent S. R. Simon
Norbert DillierNorbert Dillier
Norbert Dillier
HWHannes Wüthrich
Hannes Wüthrich
In order to study 3D auditory perception for hearing aid users, spatial audio reproduction systems have been considered. Numerous solutions were designed in the past, but few studies evaluated the effect of 3D audio reproduction artifacts on hearing devices. This study focuses on loudspeaker-based 3D audio reproduction and compares the effects of distance-based amplitude panning (DBAP), third and fifth order Ambisonics (HOA), multiple-direction amplitude panning (MDAP), and vector-base...

1 March 2013 in Cochlear Implants International
Verified
Journal Article
Closed access
WLWai Kong Lai
Wai Kong Lai
Norbert DillierNorbert Dillier
Norbert Dillier
Being able to display and analyse the output of a speech processor that encodes the parameters of complex stimuli to be presented by a cochlear implant (CI) is useful for software and hardware development as well asfor diagnostic purposes. This firstly requires appropriate hardware that is able to receive and decode theradio frequency (RF)-coded signals, and then processing the decoded data using suitable software. The PCI-IF6 clinical hardware for the Nucleus CI system, together with the Nucleus Implant Communicator and Nucleus Matlab Toolbox research software libraries, provide the necessary functionality. RFcap is a standalone Matlab application that encapsulates the relevant functions to capture, display, and analyse the RF-coded signals intended for the Nucleus CI24M/R, CI24RE, and CI500 multichannel CIs

1 May 2008 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
JWJan Wouters
Jan Wouters
HLHeleen Luts
Heleen Luts
KEKoen Eneman
Koen Eneman
ASAnn Spriet
Ann Spriet
MMMarc Moonen
Marc Moonen
MVM Vormann
M Vormann
Digital hearing aids of today allow the application of advanced signal processing strategies. In recent years a number of promising signal processing approaches have been designed and developed. However, most of these different evolutions have been evaluated only in a limited way. Within the framework of the HEARCOM EU‐research project a number of signal enhancement techniques have been further developed and evaluated based on a representative set of real‐life recordings and physical performance measures. Different auditory profiles, representing common categories of hearing aid users, have been taken into account. A selection of 5 of these signal enhancement techniques (single‐channel noise suppression, blind source separation, dereverberation, multi‐microphone adaptive processing, feedback reduction) has been implemented on a single common hard‐ and software test platform, the Master Hearing Aid (MHA). These signal processing strategies have been evaluated perceptually based on speech reception thresholds, listening effort and preference rating, at 5 different test‐sites for a number of speech‐and‐noise listening scenarios. Fifty normal hearing subjects and 100 hearing aid users according to 2 auditory profiles, took part in this study.