Dilton Martins Pimentel

Dr. Dilton Martins Pimentel

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Microchemical Journal
Verified
Journal Article
Closed access
KTKarine R. Teófilo
Karine R. Teófilo
Luciano ArantesLuciano Arantes
Luciano Arantes
PMPablo A. Marinho
Pablo A. Marinho
AMAnne A. Macedo
Anne A. Macedo
Dilton Martins PimentelDilton Martins Pimentel
Dilton Martins Pimentel
WSWallans T.P. dos Santos
Wallans T.P. dos Santos

1 September 2020 in Electrochimica Acta
Verified
Journal Article
Closed access
CLCamila D. Lima
Camila D. Lima
RCRosa A.S. Couto
Rosa A.S. Couto
Luciano ArantesLuciano Arantes
Luciano Arantes
PMPablo A. Marinho
Pablo A. Marinho
Dilton Martins PimentelDilton Martins Pimentel
Dilton Martins Pimentel
WSWallans T.P. dos Santos
Wallans T.P. dos Santos

24 February 2022 in Electrochimica Acta
Verified
Journal Article
Closed access
MAMariane O.B. Arrieiro
Mariane O.B. Arrieiro
Luciano ArantesLuciano Arantes
Luciano Arantes
DMDebora A.R. Moreira
Debora A.R. Moreira
Dilton Martins PimentelDilton Martins Pimentel
Dilton Martins Pimentel
CLCamila D. Lima
Camila D. Lima
WSWallans T.P. dos Santos
Wallans T.P. dos Santos

16 April 2018 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
GSGlayton A. Souza
Glayton A. Souza
Dilton Martins PimentelDilton Martins Pimentel
Dilton Martins Pimentel
ALAmanda B. Lima
Amanda B. Lima
TGTiago J. Guedes
Tiago J. Guedes
Luciano ArantesLuciano Arantes
Luciano Arantes
WSWallans T. P. dos Santos
Wallans T. P. dos Santos
The electrochemical quantification of new psychoactive substances 2,5-dimethoxy-N-(2-methoxybenzyl)phenethylamines, commonly described as NBOMes and their correlates, 2,5-dimethoxy phenethylamine structures, also known as 2C family compounds, in seized blotting paper is presented using square-wave voltammetry (SWV) on a boron-doped diamond (BDD) electrode. Under optimized experimental conditions, linear analytical curves were obtained in the range from 1 to 555 μmol L−1 for three NBOMes and 2C–B with detection limit values between 0.1 and 0.3 μmol L−1 (corresponding to 0.03 and 0.10 μg mL−1) and a repeatability of around 1% (n = 10) for the detection of all analytes. The accuracy of the proposed method was evaluated using seized samples, which were also analyzed by quadrupole time of flight liquid chromatography-mass spectrometry (QTOF LC-MS), with perfect agreement, and free from interference of the sample matrix (recovery values between 98 and 110%).

1 October 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Dilton Martins PimentelDilton Martins Pimentel
Dilton Martins Pimentel
Luciano ArantesLuciano Arantes
Luciano Arantes
LSLuan M. Santos
Luan M. Santos
KSKarla A.O. Souza
Karla A.O. Souza
RVRodrigo Verly
Rodrigo Verly
WSWallans T.P. dos Santos
Wallans T.P. dos Santos

19 June 2023 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LMLarissa M.A. Melo
Larissa M.A. Melo
Luciano ArantesLuciano Arantes
Luciano Arantes
Dilton Martins PimentelDilton Martins Pimentel
Dilton Martins Pimentel
AMAnne A. Macedo
Anne A. Macedo
RVRodrigo M. Verly
Rodrigo M. Verly
WSWallans T.P. dos Santos
Wallans T.P. dos Santos