This paper presents a new modulation and control strategies for the high-frequency link matrix converter (HFLMC). The proposed method aims to achieve controllable power factor in the grid interface as well as voltage and current regulation for a battery energy storage device. The matrix converter (MC) is a key element of the system, since it performs a direct ac to ac conversion between the grid and the power transformer, dispensing the traditional dc-link capacitors. Therefore, the circuit volume and weight are reduced and a longer service life is expected when compared with the existing technical solutions. A prototype was built to validate the mathematical analysis and the simulation results. Experimental tests developed in this paper show the capability of controling the grid currents in the synchronous reference frame in order to provide grid services. Simultaneously, the battery current is well regulated with small ripple, which makes this converter ideal for battery charging of electric vehicles and energy storage applications.
Matrix converters (MCs) allow the implementation of single-stage AC/AC power conversion systems (PCS) with inherent bidirectional power flow capability. By avoiding the typical DC-link capacitor, MCs have the potential to achieve higher power density with a more reliable operation and less maintenance when compared with conventional two-stage AC/DC/AC PCS. For these reasons, matrix converters have been receiving significant attention from the academic sector but have not yet been implemented on a large industrial scale. This article reviews the Direct Matrix Converter (DMC) and the Indirect Matrix Converter (IMC) along with the respective actual and most important modulation methods. Simulation results are provided to validate the theoretical analysis and to get a deep insight about the implementation of space vector modulation (SVM) and respective switching pattern generator.
This paper describes the design of an electromagnetic interference (EMI) filter for the high-frequency link matrix converter (HFLMC). The proposed method aims to systematize the design process for pre-compliance with CISPR 11 Class B standard in the frequency range 150 kHz to 30 MHz. This approach can be extended to other current source converters which allows time-savings during the project of the filter. Conducted emissions are estimated through extended simulation and take into account the effect of the measurement apparatus. Differential-mode (DM) and common-mode (CM) filtering stages are projected separately and then integrated in a synergistic way in a single PCB to reduce volume and weight. A prototype of the filter was constructed and tested in the laboratory. Experimental results with the characterization of the insertion losses following the CISPR 17 standard are provided. The attenuation capability of the filter was demonstrated in the final part of the paper.
This paper describes a power conversion system that implements bidirectional power flow between the electric grid and a battery, based on a full bridge inverter associated with a dual active bridge. A method for power flow control based on the agreement between battery pack and low voltage grid requirements has been developed to allow the large penetration of both, electric vehicles (EV) and renewable microgeneration. A laboratory prototype containing all functions required to implement a vehicle-to-grid (V2G) power interface has been built. The hardware implementation is reported, including control scheme and high-frequency transformer design details. Converter key waveforms are presented to evaluate the power quality on batteries and grid, as well as its dynamic behavior. An experimental laboratory setup is described and results are shown to demonstrate the technical benefits for low-voltage (LV) microgrids, if electric vehicle charger includes a power flow control based on frequency-voltage droop concept.
This paper presents an approach to design the transformer and the link inductor for the high-frequency link matrix converter. The proposed method aims to systematize the design process of the HF-link using analytic and software tools. The models for the characterization of the core and winding losses have been reviewed. Considerations about the practical implementation and construction of the magnetic devices are also provided. The software receives the inputs from the mathematical analysis and runs the optimization to find the best design. A 10 kW / 20 kHz transformer plus a link inductor are designed using this strategy achieving a combined efficiency of 99.32%.