In this letter, we report an observation of room temperature electrical oscillation in vanadium dioxide (VO2), a representative strongly correlated material showing a metal-insulator transition. An electric circuit for the oscillation is simply composed of a voltage source and two-terminal VO2 thin film device serially connected with a standard resistor. The systematic procedures where the oscillation occurred were explained based on the electrical relationship between the VO2 device and resistor, and the generation window of the oscillation was determined. In particular, the oscillation frequency could be controlled by adjusting an external voltage and increased up to >0.5MHz.
In order to investigate bistable switching characteristics of planar junction devices based on vanadium dioxide (VO2) thin films, we have measured the optical power dependence of the threshold voltage of the device, at which a current jump, regarded as the Mott metal-insulator transition (MIT), happened, by using an infrared laser with a wavelength of ∼1.55 μm, illuminated onto the VO2 film. In a test closed loop circuit connecting a DC voltage source, a standard resistor, and a VO2 thin film device in series, the bistability of the voltage across the device (VD) was examined with respect to a variety of illumination powers (PLs). By triggering the forward or reverse phase transition (Mott MIT) of the VO2 film with “SET” or “RESET” optical pulse, respectively, the photo-assisted bistable switching of VD in the test circuit properly DC biased could be realized at an intermediate PL chosen between optical powers of “SET” and “RESET” pulses. In particular, the transient response of VD showed not only bistable states of VD but also their switching speed.
High-sensitivity temperature sensors have been used to validate real-time thermal responses in tissue during photothermal treatment. The objective of the current study was to evaluate the feasible application of a fiber Bragg grating (FBG) sensor for diffuser-assisted laser-induced interstitial thermotherapy (LITT) particularly to treat tubular tissue disease. A core-diameter diffuser was employed to deliver 980-nm laser light for coagulation treatment. Both a thermocouple and a FBG were comparatively tested to evaluate temperature measurements in ex vivo liver tissue. The degree of tissue denaturation was estimated as a function of irradiation times and quantitatively compared with light distribution as well as temperature development. At the closer distance to a heat source, the thermocouple measured up to 41% higher maximum temperature than the FBG sensor did after 120-s irradiation (i.e., for FBG versus for thermocouple; ). Ex vivo porcine urethra tests confirmed the real-time temperature measurements of the FBG sensor as well as consistently circumferential tissue denaturation after 72-s irradiation (). The implementation of FBG can be a feasible sensing technique to instantaneously monitor the temperature developments during diffuser-assisted LITT for treatment of tubular tissue structure.
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
Here, we report an optical fiber sensor capable of performing strain-insensitive simultaneous measurements of torsion and temperature using a long-period fiber grating (LPFG) inscribed on twisted double-clad fiber (DCF) with a CO 2 laser. The LPFG written on twisted DCF, referred to as TDC-LPFG, exhibited multiple resonance dips with different cladding-mode orders, and two of them were selected as sensor indicators for the simultaneous measurement of torsion and temperature. The measured torsion sensitivities of the sensor indicators were approximately –2.167×10 2 and –4.667×10 2 pm/(rad/m) in a twist angle range of –180° to 180°, and their temperature sensitivities were measured as ~6.580×10 1 and ~7.189×10 1 pm/°C in a temperature range of 25–100 °C. Their linear and independent responses to torsion and temperature made possible the discrimination of the two measurands. Moreover, the strain sensitivity of the TDC-LPFG was measured and found to be less than 2.750×10 1 pm/με in magnitude, over four times less than that of a standard LPFG. This strain insensitiveness contributes strongly to diminishing strain-induced measurement uncertainties associated with torsion and temperature. Finally, we validated the simultaneous measurement capability of twenty-five applied points of torsion and temperature variations. The average torsion and temperature standard deviations were ~3.44×10 -2 rad/m and ~3.01×10 -1 °C, respectively.