DORIN HARPAZ

Dr. DORIN HARPAZ

Nanyang Technological Univeristy
+3
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2017 in Biosensors
Verified
Journal Article
Open access
PDF file
DHDORIN HARPAZ
DORIN HARPAZ
EEEvgeni Eltzov
Evgeni Eltzov
RSRaymond C.S. Seet
Raymond C.S. Seet
Robert MarksRobert Marks
Robert Marks
ATAlfred Tok
Alfred Tok
Stroke, the second highest leading cause of death, is caused by an abrupt interruption of blood to the brain. Supply of blood needs to be promptly restored to salvage brain tissues from irreversible neuronal death. Existing assessment of stroke patients is based largely on detailed clinical evaluation that is complemented by neuroimaging methods. However, emerging data point to the potential use of blood-derived biomarkers in aiding clinical decision-making especially in the diagnosis of ischemic stroke, triaging patients for acute reperfusion therapies, and in informing stroke mechanisms and prognosis. The demand for newer techniques to deliver individualized information on-site for incorporation into a time-sensitive work-flow has become greater. In this review, we examine the roles of a portable and easy to use point-of-care-test (POCT) in shortening the time-to-treatment, classifying stroke subtypes and improving patient’s outcome. We first examine the conventional stroke management workflow, then highlight situations where a bedside biomarker assessment might aid clinical decision-making. A novel stroke POCT approach is presented, which combines the use of quantitative and multiplex POCT platforms for the detection of specific stroke biomarkers, as well as data-mining tools to drive analytical processes. Further work is needed in the development of POCTs to fulfill an unmet need in acute stroke management.

3 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
DHDORIN HARPAZ
DORIN HARPAZ
BKBrescia Koh
Brescia Koh
Robert MarksRobert Marks
Robert Marks
RSRaymond C.S. Seet
Raymond C.S. Seet
Ibrahim AbdulhalimIbrahim Abdulhalim
Ibrahim Abdulhalim
ATAlfred Tok
Alfred Tok
Surface-plasmon-resonance (SPR) is a quantum-electromagnetic phenomenon arising from the interaction of light with free electrons at a metal-dielectric interface. At a specific angle/wavelength of light, the photon’s energy is transferred to excite the oscillation of the free electrons on the surface. A change in the refractive-index (RI) may occur, which is influenced by the analyte concentration in the medium in close contact with the metal surface. SPR has been widely used for the detection of gaseous, liquid, or solid samples. In this study, a functionalized specific SPR chip was designed and used in a novel point-of-care SPR module (PhotonicSys SPR H5) for the detection of the stroke biomarkers NT-proBNP and S100β. These biomarkers have proven to be good for stroke diagnosis, with sensitivity and specificity of >85%. Specific detection was done by binding a biomolecular-recognizing antibody onto the Au SPR-chip. Detection was tested in water and plasma samples. NT-proBNP and S100β were detected in a range of concentrations for stroke, from 0.1 ng/mL to 10 ng/mL. The RI of the blank plasma samples was 1.362412, and the lowest concentration tested for both biomarkers showed a prominent shift in the RI signal (0.25 ng/mL NT-proBNP (1.364215) and S100β (1.364024)). The sensor demonstrated a clinically relevant limit-of-detection of less than ng/mL.

22 January 2019 in Materials
Verified
Journal Article
Open access
PDF file
DHDORIN HARPAZ
DORIN HARPAZ
TATim Axelrod
Tim Axelrod
AYAlicia Lu Yitian
Alicia Lu Yitian
Evgeni EltzovEvgeni Eltzov
Evgeni Eltzov
Robert MarksRobert Marks
Robert Marks
ATAlfred Tok
Alfred Tok
Integrating a dissolvable membrane into a sensor allows the control of sample flow, location and duration in critical areas. These time-barrier films stop the flow of samples until the membrane has dissolved, thus, for example, allowing increased exposure time between immunoreagents for the formation of greater numbers of immuno-complexes, ensuring higher sensitivity, reactivity, and helping to reduce false-positive signals. In this study, dissolvable polyvinyl alcohol (PVA) films are used in a 3D-printed sensor holder, which enables film integration without the use of glue. PVA is a synthetic hydrophilic linear polymer, its solubility is dependent on its molecular weight and degree of hydrolysis. Three types of PVAs films were tested herein: (1) PVA 1-Mw: 30–70 K, 87–90% hydrolyzed; (2) PVA 2-Mw: 31–50 K, 98–99% hydrolyzed and (3) PVA 3-Mw: 89–98 K, >99% hydrolyzed. The films were exposed to water in (1) the novel 3D-printed holder and (2) directly immersed into a water droplet. After comparing the time taken to dissolve PVA 1–3 films, PVA 1 films of 5–20% (w/v) are found to be most suitable as time barrier films, due to their optimal dissolution times and physical properties for integration into the customized 3D-printed holder.

25 September 2018 in Molecules
Verified
Journal Article
Open access
PDF file
DHDORIN HARPAZ
DORIN HARPAZ
LYLoo Pin Yeo
Loo Pin Yeo
FCFrancesca Cecchini
Francesca Cecchini
TKTrish H. P. Koon
Trish H. P. Koon
AKAriel Kushmaro
Ariel Kushmaro
Evgeni EltzovEvgeni Eltzov
Evgeni Eltzov
Artificial sweeteners have become increasingly controversial due to their questionable influence on consumers’ health. They are introduced in most foods and many consume this added ingredient without their knowledge. Currently, there is still no consensus regarding the health consequences of artificial sweeteners intake as they have not been fully investigated. Consumption of artificial sweeteners has been linked with adverse effects such as cancer, weight gain, metabolic disorders, type-2 diabetes and alteration of gut microbiota activity. Moreover, artificial sweeteners have been identified as emerging environmental pollutants, and can be found in receiving waters, i.e., surface waters, groundwater aquifers and drinking waters. In this study, the relative toxicity of six FDA-approved artificial sweeteners (aspartame, sucralose, saccharine, neotame, advantame and acesulfame potassium-k (ace-k)) and that of ten sport supplements containing these artificial sweeteners, were tested using genetically modified bioluminescent bacteria from E. coli. The bioluminescent bacteria, which luminesce when they detect toxicants, act as a sensing model representative of the complex microbial system. Both induced luminescent signals and bacterial growth were measured. Toxic effects were found when the bacteria were exposed to certain concentrations of the artificial sweeteners. In the bioluminescence activity assay, two toxicity response patterns were observed, namely, the induction and inhibition of the bioluminescent signal. An inhibition response pattern may be observed in the response of sucralose in all the tested strains: TV1061 (MLIC = 1 mg/mL), DPD2544 (MLIC = 50 mg/mL) and DPD2794 (MLIC = 100 mg/mL). It is also observed in neotame in the DPD2544 (MLIC = 2 mg/mL) strain. On the other hand, the induction response pattern may be observed in its response in saccharin in TV1061 (MLIndC = 5 mg/mL) and DPD2794 (MLIndC = 5 mg/mL) strains, aspartame in DPD2794 (MLIndC = 4 mg/mL) strain, and ace-k in DPD2794 (MLIndC = 10 mg/mL) strain. The results of this study may help in understanding the relative toxicity of artificial sweeteners on E. coli, a sensing model representative of the gut bacteria. Furthermore, the tested bioluminescent bacterial panel can potentially be used for detecting artificial sweeteners in the environment, using a specific mode-of-action pattern.


7 January 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
DHDORIN HARPAZ
DORIN HARPAZ
Evgeni EltzovEvgeni Eltzov
Evgeni Eltzov
TNTimothy S. E. Ng
Timothy S. E. Ng
Robert MarksRobert Marks
Robert Marks
ATAlfred Tok
Alfred Tok
Paper-based colorimetric biosensors combine the use of paper with colorimetric signal detection. However, they usually demonstrate lower sensitivities because a signal amplification procedure has not been used. Stopping the reaction of colorimetric signal generation is often used in lab-based assays in order to amplify and stabilize the colorimetric signal for detection. In this study, the generation of a stopped colorimetric signal was examined for accurate and enhanced signal detection in paper-based biosensors. The colorimetric reaction in biosensors is usually based on the interaction between the enzyme horseradish peroxidase (HRP) and a selected chromogenic substrate. The two most commonly used HRP substrates, 3,3’,5,5’-tetramethylbenzidine (TMB) and 2’-azinobis (3-ethylbenzothiazoline-6-sulfonic-acid) (ABTS), were compared in terms of their ability to generate a stopped colorimetric signal on membrane. The stopped colorimetric signal was visible for TMB but not for ABTS. Moreover, the generation of stopped colorimetric signal was dependent on the presence of polyvinylidene-difluoride (PVDF) membrane as the separation layer. With PVDF the colorimetric signal (color intensity) was higher (TMB: 126 ± 6 and ABTS: 121 ± 9) in comparison to without PVDF (TMB: 110 ± 2 and ABTS: 102 ± 4). The TMB stopped colorimetric signal demonstrated a more stable signal detection with lower standard deviation values. To conclude, a stopped colorimetric signal can be generated in paper-based biosensors for enhanced and accurate signal detection.