Liao Wu

Dr. Liao Wu

School of Mechanical and Manufacturing Engineering, UNSW Sydney, Sydney, New South Wales, Australia
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Mechanism and Machine Theory
Verified
Journal Article
Closed access
ZLZheng Li
Zheng Li
LWLiao Wu
Liao Wu
Hongliang RenHongliang Ren
Hongliang Ren
HYHaoyong Yu
Haoyong Yu

1 June 2014 in Robotics and Computer-Integrated Manufacturing
Verified
Journal Article
Closed access
XYXiangdong Yang
Xiangdong Yang
LWLiao Wu
Liao Wu
JLJinquan Li
Jinquan Li
KCKen Chen
Ken Chen

13 June 2014 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
LWLiao Wu
Liao Wu
XYXiangdong Yang
Xiangdong Yang
KCKen Chen
Ken Chen
Hongliang RenHongliang Ren
Hongliang Ren
This paper proposes an algorithm for robotic kinematic calibration based on a minimal product of exponentials (POE)-based model for the applications where only position measurements are required. Both joint zero-offset errors and initial frame twist error can be involved in this model. Analysis of the identifiability of these errors shows that at most six elements of these parameters can be identified. It also suggests that at least three noncollinear points on the end-effector should be measured to maximize the identifiability. Compared with the traditional POE-based model with full pose (position and orientation) measurements, the minimal model with only position measurements outperforms in terms of convenience, efficiency, and accuracy. Note to Practitioners-Kinematic calibration is pivotal to improve the position accuracy of a robot. To avoid the disadvantages of measuring the orientation of the end-effector during calibration, an algorithm using only position measurements is presented, with which one needs only position measurements of several points fixed on the end-effector without orientation information during the whole calibration process. This will greatly facilitate the scheme design as well as the practical operations. The identifiability of the parameters is then analyzed with two conclusions: 1) at most six elements of the joint zero-offsets and the initial frame twist in total can be identified simultaneously and 2) at least three points on the end-effector which are not collinear should be measured so as to make the identifiability maximum. According to these conclusions, one should carefully select parameters to formulate the error model and measure sufficient points on the end-effector during the calibration procedure.

20 January 2016 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
LWLiao Wu
Liao Wu
Hongliang RenHongliang Ren
Hongliang Ren
When a robot is required to perform specific tasks defined in the world frame, there is a need for finding the coordinate transformation between the kinematic base frame of the robot and the world frame. The kinematic base frame used by the robot controller to define and evaluate the kinematics may deviate from the mechanical base frame constructed based on structural features. Besides, by using kinematic modeling rules such as the product of exponentials (POE) formula, the base frame can be arbitrarily located, and does not have to be related to any feature of the mechanical structure. As a result, the kinematic base frame cannot be measured directly. This paper proposes to find the kinematic base frame by solving a hand-eye calibration problem using 3D position measurements only, which avoids the inconvenience and inaccuracy of measuring orientations and thus significantly facilitates practical operations. A closed-form solution and an iterative solution are explicitly formulated and proved effective by simulations. Comprehensive analyses of the impact of key parameters to the accuracy of the solution are also carried out, providing four guidelines to better conduct practical operations. Finally, experiments on a 7-DOF industrial robot are performed with an optical tracking system to demonstrate the superiority of the proposed method using position data only over the method using full pose data.

3 March 2016 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
LWLiao Wu
Liao Wu
JWJiaole Wang
Jiaole Wang
LQLin Qi
Lin Qi
KWKeyu Wu
Keyu Wu
Hongliang RenHongliang Ren
Hongliang Ren
MMMax Q.-H. Meng
Max Q.-H. Meng
Multirobot comanipulation shows great potential in surpassing the limitations of single-robot manipulation in complicated tasks such as robotic surgeries. However, a dynamic multirobot setup in unstructured environments poses great uncertainties in robot configurations. Therefore, the coordination relationships between the end-effectors and other devices, such as cameras (hand–eye calibration) and tools (tool–flange calibration), as well as the relationships among the base frames (robot–robot calibration) have to be determined timely to enable accurate robotic cooperation for the constantly changing configuration of the systems. We formulated the problem of hand–eye, tool–flange, and robot–robot calibration to a matrix equation $\mathbf{AXB=YCZ}$ . A series of generic geometric properties and lemmas were presented, leading to the derivation of the final simultaneous algorithm. In addition to the accurate iterative solution, a closed-form solution was also introduced based on quaternions to give an initial value. To show the feasibility and superiority of the simultaneous method, two nonsimultaneous methods were compared through thorough simulations under various robot movements and noise levels. Comprehensive experiments on real robots were also performed to further validate the proposed methods. The comparison results from both simulations and experiments demonstrated the superior accuracy and efficiency of the proposed simultaneous calibration method.

28 December 2016 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
LWLiao Wu
Liao Wu
RCRoss Crawford
Ross Crawford
JRJonathan Roberts
Jonathan Roberts
Continuum robots are increasingly used in minimally invasive surgeries. To date, the concentric tube mechanism and the cable-driven mechanism have been two prevalent mechanisms for constructing continuum robots. As these two mechanisms complement each other, it is worth exploring the possibility of combining them together. In this paper, we investigate the dexterity of three continuum robots combining both mechanisms. Indices based on the concept of orientability are introduced to analyze the distribution of the dexterity. A Monte Carlo method is used to calculate the dexterity distribution across the workspace. Particularly, directional dexterity indices are put forward to describe the dexterity along different axes. Results imply that evenly allocating degrees of freedom (DOFs) among the segments achieves the best workspace and dexterity. Otherwise, assigning more DOFs to the proximal segment tends to enlarge the workspace and adding more DOFs to the distal segment tends to improve the dexterity. In addition, the dexterity along different axes can vary significantly and thus requires special attention when applying the robot to specific surgical procedures.