25 July 2024 in Molecules
Verified
Journal Article
Open access
PDF file
NLNikola Lenar
Nikola Lenar
Martyna Drużyńska-BaldyMartyna Drużyńska-Baldy
Martyna Drużyńska-Baldy
Robert PiechRobert Piech
Robert Piech
Beata Paczosa-BatorBeata Paczosa-Bator
Beata Paczosa-Bator
Carbon nanomaterials were introduced into this research as modifiers for polymeric membranes for single-piece electrodes, and their properties were studied for the case of nitrate-selective sensors. The use of graphene, carbon black and carbon nanotubes is shown to significantly improve the potentiometric response, while no redox response was observed. The use of carbon nanomaterials results in a near-Nernstian response (54 mV/pNO3−) towards nitrate ions over a wide linear range (from 10−1 to 10−6 M NO3−). The results obtained by chronopotentiometry and electrochemical impedance spectroscopy reveal little resistance, and the capacitance parameter is as high as 0.9 mF (for graphene-based sensor). The high electrical capacity of electrodes results in the good stability of the potentiometric response and a low potential drift (0.065 mV/h). Introducing carbon nanomaterials into the polymetric membrane, instead of using them as separate layers, allows for the simplification of the sensors’ preparation procedure. With single-piece electrodes, one step of the procedure could be omitted, in comparison to the procedure for the preparation of solid-contact electrodes.

6 December 2025 in Membranes
Verified
Journal Article
Open access
PDF file
Martyna Drużyńska-BaldyMartyna Drużyńska-Baldy
Martyna Drużyńska-Baldy
NLNikola Lenar
Nikola Lenar
Beata Paczosa-BatorBeata Paczosa-Bator
Beata Paczosa-Bator
Accurate potentiometric sensing critically depends on the stability and reproducibility of the reference electrode potential. Conventional liquid-filled Ag/AgCl or calomel electrodes, though well-established, are poorly compatible with miniaturized, portable, or long-term in situ sensing devices due to electrolyte leakage, junction potential instability, and maintenance requirements. Recent advances in solid-state and membrane-based reference electrodes offer a promising alternative by eliminating the liquid junction while maintaining stable and well-defined potential. This review summarizes the advancements in polymer-based and composite reference membranes, focusing on material strategies, stabilization mechanisms, and integration approaches. Emphasis is placed on ionic-liquid-doped membranes, conducting polymers, lipophilic salts, and carbon nanomaterials as functional components enhancing interfacial stability and charge transfer. The performances of various architectures, solid-contact, liquid-junction-free, and quasi-reference systems, are compared in terms of potential drift, matrix resistance, biocompatibility, and manufacturability. Furthermore, recent developments in printed, microfluidic, and wearable potentiometric platforms demonstrate how reference membrane innovations enable reliable operation in compact, low-cost, and flexible analytical systems. The review outlines current trends, challenges, and future directions toward universal, miniaturized, and leak-free reference electrodes suitable for innovative sensing technologies.

25 August 2025 in Molecules
Verified
Journal Article
Open access
PDF file
Martyna Drużyńska-BaldyMartyna Drużyńska-Baldy
Martyna Drużyńska-Baldy
NLNikola Lenar
Nikola Lenar
Beata Paczosa-BatorBeata Paczosa-Bator
Beata Paczosa-Bator
Lead contamination remains a critical global concern due to its persistent toxicity, bioaccumulative nature, and widespread occurrence in water, food, and industrial environments. The accurate, cost-effective, and rapid detection of lead ions (Pb2+) is essential for protecting public health and ensuring environmental safety. Among the available techniques, potentiometric sensors, particularly ion-selective electrodes (ISEs), have emerged as practical tools owing to their simplicity, portability, low power requirements, and high selectivity. This review summarizes recent progress in lead-selective potentiometry, with an emphasis on electrode architectures and material innovations that enhance analytical performance. Reported sensors achieve detection limits as low as 10−10 M, broad linear ranges typically spanning 10−10–10−2 M, and near-Nernstian sensitivities of ~28–31 mV per decade. Many designs also demonstrate reproducible responses in complex matrices. Comparative analysis highlights advances in traditional liquid-contact electrodes and modern solid-contact designs modified with nanomaterials, ionic liquids, and conducting polymers. Current challenges—including long-term stability, calibration frequency, and selectivity against competing metal ions—are discussed, and future directions for more sensitive, selective, and user-friendly Pb2+ sensors are outlined.

5 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Martyna Drużyńska-BaldyMartyna Drużyńska-Baldy
Martyna Drużyńska-Baldy
NLNikola Lenar
Nikola Lenar
Beata Paczosa-BatorBeata Paczosa-Bator
Beata Paczosa-Bator
Electrochemical impedance spectroscopy (EIS) is a powerful, non-destructive tool for evaluating ion-selective electrode (ISE) membrane condition. This work investigated EIS for identifying degradation mechanisms in all-solid-state Pb2+-selective electrodes. Graphene-containing PVC membranes deposited on glassy carbon electrodes were exposed to synthetic urine, river water, and seawater (24 h and 1 week) and to mechanical damage (cutting, needle puncture, or both). Degradation was assessed using EIS, potentiometric measurements, contact-angle analysis, profilometry, and SEM. River water and urine exposure decreased hydrophobicity, increased roughness, and produced fouling deposits. Seawater caused only minor morphological and wettability changes, though impedance data showed increased membrane hydration due to high ionic strength. Mechanical damage substantially disrupted membrane integrity, causing pronounced impedance changes, increased potential drift, and reduced analytical performance. Fouling and mechanical damage produced distinct electrochemical signatures: fouling mainly affected surface properties, while mechanical damage altered the membrane–transducer interface, increasing capacitance and reducing resistance. Notably, needle-punctured electrodes retained a near-Nernstian response despite clear impedance changes and reduced long-term stability, showing that EIS detects defects invisible to conventional calibration. These results confirm EIS as a sensitive method for distinguishing fouling from physical damage, useful for early degradation detection and lifetime monitoring of all-solid-state ISEs.

30 May 2025 in Molecules
Verified
Journal Article
Open access
PDF file
Martyna Drużyńska-BaldyMartyna Drużyńska-Baldy
Martyna Drużyńska-Baldy
Timo KikasTimo Kikas
Timo Kikas
NLNikola Lenar
Nikola Lenar
Beata Paczosa-BatorBeata Paczosa-Bator
Beata Paczosa-Bator
This work presents an idea for a new reliable potentiometric sensor for nitrate ion determination. The paper provides the optimized procedure for the preparation and maintenance of single-piece nitrate-selective electrodes with carbon black nanoparticles. The optimal carbon black amount was selected based on the electrical properties of the designed sensors. The 5% addition of carbon nanomaterial to the polymeric membrane ensured the highest electrical capacitance (of 610 µF) and the lowest resistance (of 421 kΩ); therefore, this amount was further applied to design single-piece sensors. The influence of carbon black incorporation into the membrane on the analytical performance of the nitrate-selective electrodes was investigated, focusing on parameters such as sensitivity, selectivity, detection limit, and potential stability. Carbon black-modified nitrate-selective sensors exhibit a near-Nernstian response in a wide range of nitrate ion concentrations (with a detection limit of 7 × 10−7). Remarkable potential stability, ensured by the hydrophobic properties of the modified membrane, was evaluated during the water-layer test and the calculated potential drift equaled 0.052 mV/h.

26 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Martyna Drużyńska-BaldyMartyna Drużyńska-Baldy
Martyna Drużyńska-Baldy
NLNikola Lenar
Nikola Lenar
Beata Paczosa-BatorBeata Paczosa-Bator
Beata Paczosa-Bator
Lead contamination remains a significant environmental and public health concern, creating a demand for analytical platforms that combine sensitivity, simplicity, and long-term stability. In this work, a graphene-containing molecular membrane matrix was developed for the fabrication of single-piece all-solid-state potentiometric sensors for Pb(II) detection. The sensing membrane consisted of poly(vinyl chloride), plasticizers, a Pb(II)-selective ionophore, lipophilic ionic sites, and dispersed graphene nanostructures, forming an integrated molecular sensing interface. Within the membrane phase, selective complexation of Pb(II) ions by the ionophore was coupled with graphene-assisted ion-to-electron transduction, enabling efficient signal generation without the need for a separate solid-contact layer. The influence of graphene incorporation and membrane thickness on sensor performance was systematically investigated. Among the tested configurations, a membrane prepared from 40 µL of sensing cocktail provided the best overall performance, combining high electrical capacitance, favorable surface properties, and superior potential stability. SEM imaging revealed a homogeneous membrane morphology without large graphene agglomerates, indicating effective dispersion of graphene within the polymer matrix. The optimized sensor exhibited a near-Nernstian slope of 30.3 mV dec−1, a linear response range from 1.0 × 10−7 to 1.0 × 10−2 M, a detection limit of 6.3 × 10−8 M, and a potential drift of only 0.35 mV h−1. These results demonstrate that direct incorporation of graphene into an ion-selective membrane is an effective strategy for constructing robust and scalable single-piece potentiometric sensors for Pb(II) monitoring and highlight the potential of developed membrane materials for electrochemical sensing applications.