Dario Santonocito

Dr. Dario Santonocito

Università degli Studi di Messina
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2019 in Materials
Verified
Journal Article
Open access
PDF file
Gabriele CervinoGabriele Cervino
Gabriele Cervino
Luca FiorilloLuca Fiorillo
Luca Fiorillo
GIGaetano Iannello
Gaetano Iannello
Dario SantonocitoDario Santonocito
Dario Santonocito
Giacomo RisitanoGiacomo Risitano
Giacomo Risitano
Marco CicciùMarco Cicciù
Marco Cicciù
The field of dental implantology has made progress in recent years, allowing safer and predictable oral rehabilitations. Surely the rehabilitation times have also been reduced, thanks to the advent of the new implant surfaces, which favour the osseointegration phases and allow the clinician to rehabilitate their patients earlier. To carry out this study, a search was conducted in the Pubmed, Embase and Elsevier databases; the articles initially obtained according to the keywords used numbered 283, and then subsequently reduced to 10 once the inclusion and exclusion criteria were applied. The review that has been carried out on this type of surface allows us to fully understand the features and above all to evaluate all the advantages or not related. The study materials also are supported by a manufacturing company, which provided all the indications regarding surface treatment and confocal microscopy scans. In conclusion, we can say that, thanks to these new surfaces, it has been possible to shorten the time necessary to obtain osseointegration and, therefore, secondary stability on the part of implants. The surfaces, therefore, guarantee an improved cellular adhesion and thanks to the excellent wettability all the biological processes that derive from it, such as increases in the exposed implant surface, resulting in an increase in bone-implant contact (BIC).

14 November 2019 in Prosthesis
Verified
Journal Article
Open access
PDF file
Marco CicciùMarco Cicciù
Marco Cicciù
Gabriele CervinoGabriele Cervino
Gabriele Cervino
ATAntonella Terranova
Antonella Terranova
Giacomo RisitanoGiacomo Risitano
Giacomo Risitano
MRMarcello Raffaele
Marcello Raffaele
Luca FiorilloLuca Fiorillo
Luca Fiorillo
In recent years the science of dental materials and implantology have taken many steps forward. In particular, it has tended to optimize the implant design, the implant surface, or the connection between implant and abutment. All these features have been improved or modified to obtain a better response from the body, better biomechanics, increased bone implant contact surface, and better immunological response. The purpose of this article, carried out by a multidisciplinary team, is to evaluate and understand, through the use also of bioengineering tests, the biomechanical aspects, and those induced on the patient’s tissues, by dental implants. A comparative analysis on different dental implants of the same manufacturer was carried out to evaluate biomechanical and molecular features. Von Mises analysis has given results regarding the biomechanical behavior of these implants and above all the repercussions on the patient’s tissues. Knowing and understanding the biomechanical characteristics with studies of this type could help improve their characteristics in order to have more predictable oral rehabilitations.

12 November 2019 in Fatigue & Fracture of Engineering Materials & Structures
Verified
Journal Article
Closed access
PDF file
Pasqualino CoriglianoPasqualino Corigliano
Pasqualino Corigliano
Filippo CucinottaFilippo Cucinotta
Filippo Cucinotta
EGEugenio Guglielmino
Eugenio Guglielmino
Giacomo RisitanoGiacomo Risitano
Giacomo Risitano
Dario SantonocitoDario Santonocito
Dario Santonocito

1 March 2021 in Engineering Structures
Verified
Journal Article
Closed access
PFPietro Foti
Pietro Foti
Dario SantonocitoDario Santonocito
Dario Santonocito
GRGiacomo Risitano
Giacomo Risitano
FBFilippo Berto
Filippo Berto

27 November 2019 in Prosthesis
Verified
Journal Article
Open access
PDF file
Gabriele CervinoGabriele Cervino
Gabriele Cervino
MMMarco Montanari
Marco Montanari
Dario SantonocitoDario Santonocito
Dario Santonocito
FNFabiana Nicita
Fabiana Nicita
RBRiccardo Bladari
Riccardo Bladari
Luca FiorilloLuca Fiorillo
Luca Fiorillo
In recent years, a major research goal of companies has been to create mechanical components suitable for rehabilitation that are safer and more reliable. Evaluating their biomechanical features could be a way to improve them. The purpose of this study was to evaluate the different biomechanical features of low-profile retentive systems (Rhein®). Two different attachment systems were tested: OT Equator® Smart Box and Locator® R-TX. Once a machine was created for the simulation of the connection and disconnection of the attacks in a combined manner, it was possible to evaluate these parameters over time. Attachments were mounted in two different configurations of the divergence angle: 10° and 50°. The drop retention force proved to be stable over time. The Locator® R-TX attachment experienced a more rapid decrement of the retention force than the OT Equator® Smart Box. Both tested systems experienced a high drop in retention; this drop tended to stabilize after 1.5 years of use, and it was correlated with the divergence angle. The OT Equator® Smart Box system underwent this loss of retention more gradually than the Locator® R-TX. This study demonstrates preliminary results from a bioengineering and biomechanical point of view, providing useful information for the continuous improvement of these devices and, therefore, for the quality of patients’ oral health.

28 April 2019
Verified
Book Chapter
Closed access
PDF file
Filippo CucinottaFilippo Cucinotta
Filippo Cucinotta
EGE. Guglielmino
E. Guglielmino
GLG. Longo
G. Longo
GRG. Risitano
G. Risitano
Dario SantonocitoDario Santonocito
Dario Santonocito
FSF. Sfravara
F. Sfravara