Introduction There has been a phenomenal worldwide increase in the development and use of mobile health applications (mHealth apps) that monitor menstruation and fertility. Critics argue that many of the apps are inaccurate and lack evidence from either clinical trials or user experience. The aim of this scoping review is to provide an overview of the research literature on mHealth apps that track menstruation and fertility. Methods This project followed the PRISMA Extension for Scoping Reviews. The ACM, CINAHL, Google Scholar, PubMed and Scopus databases were searched for material published between 1 January 2010 and 30 April 2019. Data summary and synthesis were used to chart and analyse the data. Results In total 654 records were reviewed. Subsequently, 135 duplicate records and 501 records that did not meet the inclusion criteria were removed. Eighteen records from 13 countries form the basis of this review. The papers reviewed cover a variety of disciplinary and methodological frameworks. Three main themes were identified: fertility and reproductive health tracking, pregnancy planning, and pregnancy prevention. Conclusions Motivations for fertility app use are varied, overlap and change over time, although women want apps that are accurate and evidence-based regardless of whether they are tracking their fertility, planning a pregnancy or using the app as a form of contraception. There is a lack of critical debate and engagement in the development, evaluation, usage and regulation of fertility and menstruation apps. The paucity of evidence-based research and absence of fertility, health professionals and users in studies is raised.
Background: We developed CEPS as an open access MATLAB® GUI (graphical user interface) for the analysis of Complexity and Entropy in Physiological Signals (CEPS), and demonstrate its use with an example data set that shows the effects of paced breathing (PB) on variability of heart, pulse and respiration rates. CEPS is also sufficiently adaptable to be used for other time series physiological data such as EEG (electroencephalography), postural sway or temperature measurements. Methods: Data were collected from a convenience sample of nine healthy adults in a pilot for a larger study investigating the effects on vagal tone of breathing paced at various different rates, part of a development programme for a home training stress reduction system. Results: The current version of CEPS focuses on those complexity and entropy measures that appear most frequently in the literature, together with some recently introduced entropy measures which may have advantages over those that are more established. Ten methods of estimating data complexity are currently included, and some 28 entropy measures. The GUI also includes a section for data pre-processing and standard ancillary methods to enable parameter estimation of embedding dimension m and time delay τ (‘tau’) where required. The software is freely available under version 3 of the GNU Lesser General Public License (LGPLv3) for non-commercial users. CEPS can be downloaded from Bitbucket. In our illustration on PB, most complexity and entropy measures decreased significantly in response to breathing at 7 breaths per minute, differentiating more clearly than conventional linear, time- and frequency-domain measures between breathing states. In contrast, Higuchi fractal dimension increased during paced breathing. Conclusions: We have developed CEPS software as a physiological data visualiser able to integrate state of the art techniques. The interface is designed for clinical research and has a structure designed for integrating new tools. The aim is to strengthen collaboration between clinicians and the biomedical community, as demonstrated here by using CEPS to analyse various physiological responses to paced breathing.
The use and deployment of mobile devices across society is phenomenal with an increasing number of individuals using mobile devices to track their everyday health. However, there is a paucity of academic material examining this recent trend. Specifically, little is known about the use and deployment of mobile heart monitoring devices for measuring palpitations and arrhythmia. In this scoping literature review, we identify the contemporary evidence that reports the use of mobile heart monitoring to assess palpitations and arrhythmia across populations. The review was conducted between February and March 2018. Five electronic databases were searched: Association for Computing Machinery (ACM), CINHAL, Google Scholar, PubMed, and Scopus. A total of 981 records were identified and, following the inclusion and exclusion criteria, nine papers formed the final stage of the review. The results identified a total of six primary themes: purpose, environment, population, wearable devices, assessment, and study design. A further 24 secondary themes were identified across the primary themes. These included detection, cost effectiveness, recruitment, type of setting, type of assessment, and commercial or purpose-built mobile device. This scoping review highlights that further work is required to understand the impact of mobile heart monitoring devices on how arrhythmias and palpitations are assessed and measured across all populations and ages of society. A positive trend revealed by this review demonstrates how mobile heart monitoring devices can support primary care providers to deliver high levels of care at a low cost to the service provider. This has several benefits: alleviation of patient anxiety, lowering the risk of morbidity and mortality, while progressively influencing national and international care pathway guidelines. Limitations of this work include the paucity of knowledge and insight from primary care providers and lack of qualitative material. We argue that future studies consider qualitative and mixed methods approaches to complement quantitative methodologies and to ensure all actors’ experiences are recorded.
Background: As technology becomes more sophisticated, more accessible methods of interpretating Big Data become essential. We have continued to develop Complexity and Entropy in Physiological Signals (CEPS) as an open access MATLAB® GUI (graphical user interface) providing multiple methods for the modification and analysis of physiological data. Methods: To demonstrate the functionality of the software, data were collected from 44 healthy adults for a study investigating the effects on vagal tone of breathing paced at five different rates, as well as self-paced and un-paced. Five-minute 15-s recordings were used. Results were also compared with those from shorter segments of the data. Electrocardiogram (ECG), electrodermal activity (EDA) and Respiration (RSP) data were recorded. Particular attention was paid to COVID risk mitigation, and to parameter tuning for the CEPS measures. For comparison, data were processed using Kubios HRV, RR-APET and DynamicalSystems.jl software. We also compared findings for ECG RR interval (RRi) data resampled at 4 Hz (4R) or 10 Hz (10R), and non-resampled (noR). In total, we used around 190–220 measures from CEPS at various scales, depending on the analysis undertaken, with our investigation focused on three families of measures: 22 fractal dimension (FD) measures, 40 heart rate asymmetries or measures derived from Poincaré plots (HRA), and 8 measures based on permutation entropy (PE). Results: FDs for the RRi data differentiated strongly between breathing rates, whether data were resampled or not, increasing between 5 and 7 breaths per minute (BrPM). Largest effect sizes for RRi (4R and noR) differentiation between breathing rates were found for the PE-based measures. Measures that both differentiated well between breathing rates and were consistent across different RRi data lengths (1–5 min) included five PE-based (noR) and three FDs (4R). Of the top 12 measures with short-data values consistently within ± 5% of their values for the 5-min data, five were FDs, one was PE-based, and none were HRAs. Effect sizes were usually greater for CEPS measures than for those implemented in DynamicalSystems.jl. Conclusion: The updated CEPS software enables visualisation and analysis of multichannel physiological data using a variety of established and recently introduced complexity entropy measures. Although equal resampling is theoretically important for FD estimation, it appears that FD measures may also be usefully applied to non-resampled data.
1 July 2006 in Neurobiology of Learning and Memory
The field of signal processing using machine and deep learning algorithms has undergone significant growth in the last few years, with a wide scope of practical applications for electroencephalography (EEG). Transcutaneous electroacupuncture stimulation (TEAS) is a well-established variant of the traditional method of acupuncture that is also receiving increasing research attention. This paper presents the results of using deep learning algorithms on EEG data to investigate the effects on the brain of different frequencies of TEAS when applied to the hands in 66 participants, before, during and immediately after 20 min of stimulation. Wavelet packet decomposition (WPD) and a hybrid Convolutional Neural Network Long Short-Term Memory (CNN-LSTM) model were used to examine the central effects of this peripheral stimulation. The classification results were analysed using confusion matrices, with kappa as a metric. Contrary to expectation, the greatest differences in EEG from baseline occurred during TEAS at 80 pulses per second (pps) or in the ‘sham’ (160 pps, zero amplitude), while the smallest differences occurred during 2.5 or 10 pps stimulation (mean kappa 0.414). The mean and CV for kappa were considerably higher for the CNN-LSTM than for the Multilayer Perceptron Neural Network (MLP-NN) model. As far as we are aware, from the published literature, no prior artificial intelligence (AI) research appears to have been conducted into the effects on EEG of different frequencies of electroacupuncture-type stimulation (whether EA or TEAS). This ground-breaking study thus offers a significant contribution to the literature. However, as with all (unsupervised) DL methods, a particular challenge is that the results are not easy to interpret, due to the complexity of the algorithms and the lack of a clear understanding of the underlying mechanisms. There is therefore scope for further research that explores the effects of the frequency of TEAS on EEG using AI methods, with the most obvious place to start being a hybrid CNN-LSTM model. This would allow for better extraction of information to understand the central effects of peripheral stimulation.