Duong Thi Bach Nguyen

Prof. Dr. Duong Thi Bach Nguyen

Faculty of Civil and Environmental Engineering, Research Group R2026-UTC-08, University of Transport and Communications, Hanoi, Hà Nội, Vietnam
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

30 September 2021 in Vietnam Journal of Marine Science and Technology
Verified
Journal Article
Closed access
PDF file
Duong Thi Bach NguyenDuong Thi Bach Nguyen
Duong Thi Bach Nguyen
DADan Nguyen Anh
Dan Nguyen Anh
Now, the field experiments according to the non-destructive test method are developing widely in diagnostics and verification of structural engineering. To research and apply the impact vibration test, one of these non-destructive methods, the construction of the design dynamic analysis model is significant. The paper goes into research on the formulas to determine the dynamic spring coefficients according to Japanese and Vietnamese standards. Then, apply calculations for dynamic analysis models of pile foundations built in the Binh Thuan sea area. The impact vibration test in the field shows the appropriate formula for calculating the coefficient of dynamic springs in Binh Thuan, Vietnam.

28 October 2018
Verified
Book Chapter
Closed access
PDF file
Duong Thi Bach NguyenDuong Thi Bach Nguyen
Duong Thi Bach Nguyen
NHNguyen Huu Hung
Nguyen Huu Hung
NDNguyen Anh Dan
Nguyen Anh Dan

18 September 2013
Verified
Book Chapter
Closed access
Duong Thi Bach NguyenDuong Thi Bach Nguyen
Duong Thi Bach Nguyen
Pieter Van GelderPieter Van Gelder
Pieter Van Gelder
MHM.B. Hudson
M.B. Hudson

1 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Duong Thi Bach NguyenDuong Thi Bach Nguyen
Duong Thi Bach Nguyen
Jungwon HuhJungwon Huh
Jungwon Huh
TVThanh Thai Vu
Thanh Thai Vu
MTMinh Long Tran
Minh Long Tran
Van Ha MacVan Ha Mac
Van Ha Mac
Vietnam’s seaport system currently includes 298 ports with 588 wharves (a total length of approximately 92,275 m), which is vital in developing Vietnam’s marine economy. The piled pier, a type of wharf structure, is widely used and accounts for up to 90%, while the remaining 10% is made up of other types of wharf structures, such as gravity and sheet pile quay walls. Most wharves have been operating for over 10 years and some for even more than 50 years. Noticeably, wharves are highly vulnerable and degrade rapidly due to many factors, especially heavy load impacts and severe environmental conditions. Additionally, wharves have a higher risk of deterioration than other inland infrastructure, such as buildings and bridges. Consequently, determining a wharf’s health is an important task in maintaining normal working conditions, extending its lifecycle, and avoiding other severe damage that could lead to dangers to the safety of vehicles, facilities, and humans. Moreover, regulated quality inspections usually include only simple inspections, e.g., displacement, settlement, geometric height, and tilt; the visual inspection and determination of dimensions by simple length-measuring equipment; concrete strength testing by ultrasonic and rebound hammers; and the experimental identification of the chloride ion concentration, chloride diffusion coefficient, corrosion activity of rebar in concrete, and steel thickness. These testing methods often give local results depending on the number of test samples. Therefore, advanced diagnostic techniques for assessing the technical condition of piled piers need to be studied. The impact vibration test (IVT) is a powerful non-destructive evaluation method that indicates the overall health of structures, e.g., underground and foundation structures, according to official standards. Hence, the IVT is expected to help engineers detect the potential deterioration of overall structures. It is fundamental that, if a structure is degraded, its natural frequency will be affected. A structure’s health index and technical condition are determined based on this change. However, the IVT does not seem to be widely applied to piled piers, with no published standard; hence, controversial issues related to accuracy and reliability still remain. This motivates the present study to recommend an adjusted factor (equal to 1.16) for the health index (classified in official standards for other structures) through numerical and experimental approaches before officially applying the IVT method to piled piers. The current work focuses on the health index using the design natural frequency, which is more practical in common cases where previous historical data and the standard natural frequency are unavailable. This study also examines a huge number of influencing factors and situations through theoretical analysis, experience, and field experiments to propose an adjusted indicator. The results are achieved with several assumptions of damages, such as the degradation of materials and local damages to structural components. With the proposed adjusted indicator, the overall health of piled piers can be assessed quickly and accurately by IVT inspections in cases of incidents, accidents due to collisions, cargo falls during loading and unloading, or subsidence and erosion due to natural disasters, storms, and floods.

28 April 2021
Verified
Book Chapter
Closed access
PDF file
Duong Thi Bach NguyenDuong Thi Bach Nguyen
Duong Thi Bach Nguyen
VLVan Hien Le
Van Hien Le
DTDuc Cong Tran
Duc Cong Tran