Jungwon Huh

Prof. Jungwon Huh

Chonnam National University
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
QTQuang Huy Tran
Quang Huy Tran
DHDongyeob Han
Dongyeob Han
CKChoonghyun Kang
Choonghyun Kang
AHAchintya Haldar
Achintya Haldar
Jungwon HuhJungwon Huh
Jungwon Huh
Active thermal imaging is an effective nondestructive technique in the structural health monitoring field, especially for concrete structures not exposed directly to the sun. However, the impact of meteorological factors on the testing results is considerable and should be studied in detail. In this study, the impulse thermography technique with halogen lamps heat sources is used to detect defects in concrete structural components that are not exposed directly to sunlight and not significantly affected by the wind, such as interior bridge box-girders and buildings. To consider the effect of environment, ambient temperature and relative humidity, these factors are investigated in twelve cases of testing on a concrete slab in the laboratory, to minimize the influence of wind. The results showed that the absolute contrast between the defective and sound areas becomes more apparent with an increase of ambient temperature, and it increases at a faster rate with large and shallow delaminations than small and deep delaminations. In addition, the absolute contrast of delamination near the surface might be greater under a highly humid atmosphere. This study indicated that the results obtained from the active thermography technique will be more apparent if the inspection is conducted on a day with high ambient temperature and humidity.

1 March 2018 in Construction and Building Materials
Verified
Journal Article
Closed access
HNHuy Hoàng Nguyễn
Huy Hoàng Nguyễn
JCJeong-Il Choi
Jeong-Il Choi
KSKeum-Il Song
Keum-Il Song
JSJin-Kyu Song
Jin-Kyu Song
Jungwon HuhJungwon Huh
Jungwon Huh
Bang Yeon LeeBang Yeon Lee
Bang Yeon Lee

18 July 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jungwon HuhJungwon Huh
Jungwon Huh
QTQuang Huy Tran
Quang Huy Tran
AHAchintya Haldar
Achintya Haldar
IPInnjoon Park
Innjoon Park
JAJin-Hee Ahn
Jin-Hee Ahn
Tunnels, culverts, and subway stations are the main parts of an integrated infrastructure system. Most of them are constructed by the cut-and-cover method at shallow depths (mainly lower than 30 m) of soil deposits, where large-scale seismic ground deformation can occur with lower stiffness and strength of the soil. Therefore, the transverse racking deformation (one of the major seismic ground deformation) due to soil shear deformations should be included in the seismic design of underground structures using cost- and time-efficient methods that can achieve robustness of design and are easily understood by engineers. This paper aims to develop a simplified but comprehensive approach relating to vulnerability assessment in the form of fragility curves on a shallow two-story reinforced concrete underground box structure constructed in a highly-weathered soil. In addition, a comparison of the results of earthquakes per peak ground acceleration (PGA) is conducted to determine the effective and appropriate number for cost- and time-benefit analysis. The ground response acceleration method for buried structures (GRAMBS) is used to analyze the behavior of the structure subjected to transverse seismic loading under quasi-static conditions. Furthermore, the damage states that indicate the exceedance level of the structural strength capacity are described by the results of nonlinear static analyses (or so-called pushover analyses). The Latin hypercube sampling technique is employed to consider the uncertainties associated with the material properties and concrete cover owing to the variation in construction conditions. Finally, a large number of artificial ground shakings satisfying the design spectrum are generated in order to develop the seismic fragility curves based on the defined damage states. It is worth noting that the number of ground motions per PGA, which is equal to or larger than 20, is a reasonable value to perform a structural analysis that produces satisfactory fragility curves.

1 May 2010 in Canadian Geotechnical Journal
Verified
Journal Article
Closed access
KKKiseok Kwak
Kiseok Kwak
KKKyung Jun Kim
Kyung Jun Kim
Jungwon HuhJungwon Huh
Jungwon Huh
JLJu Hyung Lee
Ju Hyung Lee
JPJae Hyun Park
Jae Hyun Park
As part of a study to develop load and resistance factor design (LRFD) codes for foundation structures in South Korea, resistance factors for the static bearing capacity of driven steel pipe piles were calibrated in the framework of the reliability theory. A database of 52 static load test results was compiled, and the data from these load test piles were sorted into two cases: a standard penetration test (SPT) N-value at pile tip (i) less than 50 and (ii) equal to or more than 50. Reliability analyses and resistance factor calibration for the two static bearing capacity analysis methods adopted in the Korean Design standards for foundation structures were performed using the first-order reliability method (FORM) and the Monte Carlo simulation (MCS). Reliability indices and resistance factors computed by the MCS are statistically identical to those computed by FORM. Target reliability indices were selected as 2.0 and 2.33 for the group pile case and 2.5 for the single pile case. The resistance factors recommended from this study are specific for the pile foundation design and construction practice and the subsurface conditions in South Korea.

6 February 2019 in Breast Cancer
Verified
Journal Article
Closed access
PDF file
MSMin-Kyung So
Min-Kyung So
TJTae-Dong Jeong
Tae-Dong Jeong
WLWoosung Lim
Woosung Lim
BMByung-In Moon
Byung-In Moon
NPNam Sun Paik
Nam Sun Paik
Jungwon HuhJungwon Huh
Jungwon Huh

1 June 2017 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
IKIn-Tae Kim
In-Tae Kim
DDDuy Kien Dao
Duy Kien Dao
YJYoung-Soo Jeong
Young-Soo Jeong
Jungwon HuhJungwon Huh
Jungwon Huh
JAJin-Hee Ahn
Jin-Hee Ahn