Elizabeth Billings

Ms. Elizabeth Billings

Scripps Research Institute, San Diego, California, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
Xavier Domingo-AlmenaraXavier Domingo-Almenara
Xavier Domingo-Almenara
CGCarlos Guijas
Carlos Guijas
Elizabeth BillingsElizabeth Billings
Elizabeth Billings
J. Rafael Montenegro-BurkeJ. Rafael Montenegro-Burke
J. Rafael Montenegro-Burke
WUWinnie Uritboonthai
Winnie Uritboonthai
GSGary Siuzdak
Gary Siuzdak
Machine learning has been extensively applied in small molecule analysis to predict a wide range of molecular properties and processes including mass spectrometry fragmentation or chromatographic retention time. However, current approaches for retention time prediction lack sufficient accuracy due to limited available experimental data. Here we introduce the METLIN small molecule retention time (SMRT) dataset, an experimentally acquired reverse-phase chromatography retention time dataset covering up to 80,038 small molecules. To demonstrate the utility of this dataset, we deployed a deep learning model for retention time prediction applied to small molecule annotation. Results showed that in 70 $$\%$$% of the cases, the correct molecular identity was ranked among the top 3 candidates based on their predicted retention time. We anticipate that this dataset will enable the community to apply machine learning or first principles strategies to generate better models for retention time prediction.

2 July 2018 in ACS Nano
Verified
Journal Article
Closed access
Amelia PalermoAmelia Palermo
Amelia Palermo
EFErica Forsberg
Erica Forsberg
BWBenedikt Warth
Benedikt Warth
AAAries E. Aisporna
Aries E. Aisporna
Elizabeth BillingsElizabeth Billings
Elizabeth Billings
GSGary Siuzdak
Gary Siuzdak

26 March 2024 in Analytical Chemistry
Verified
Journal Article
Open access
CHCorey Hoang
Corey Hoang
WUWinnie Uritboonthai
Winnie Uritboonthai
LHLinh Hoang
Linh Hoang
Elizabeth BillingsElizabeth Billings
Elizabeth Billings
AAAries Aisporna
Aries Aisporna
GSGary Siuzdak
Gary Siuzdak
PubChem serves as a comprehensive repository, housing over 100 million unique chemical structures representing the breadth of our chemical knowledge across numerous fields including metabolism, pharmaceuticals, toxicology, cosmetics, agriculture, and many more. Rapid identification of these small molecules increasingly relies on electrospray ionization (ESI) paired with tandem mass spectrometry (MS/MS), particularly by comparison to genuine standard MS/MS data sets. Despite its widespread application, achieving consistency in MS/MS data across various analytical platforms remains an unaddressed concern. This study evaluated MS/MS data derived from one hundred molecular standards utilizing instruments from five manufacturers, inclusive of quadrupole time-of-flight (QTOF) and quadrupole orbitrap "exactive" (QE) mass spectrometers by Agilent (QTOF), Bruker (QTOF), SCIEX (QTOF), Waters (QTOF), and Thermo QE. We assessed fragment ion variations at multiple collisional energies (0, 10, 20, and 40 eV) using the cosine scoring algorithm for comparisons and the number of fragments observed. A parallel visual analysis of the MS/MS spectra across instruments was conducted, consistent with a standard procedure that is used to circumvent the still prevalent issue of mischaracterizations as shown for dimethyl sphingosine and C20 sphingosine. Our analysis revealed a notable consistency in MS/MS data and identifications, with fragment ions' m/z values exhibiting the highest concordance between instrument platforms at 20 eV, the other collisional energies (0, 10, and 40 eV) were significantly lower. While moving toward a standardized ESI MS/MS protocol is required for dependable molecular characterization, our results also underscore the continued importance of corroborating MS/MS data against standards to ensure accurate identifications. Our findings suggest that ESI MS/MS manufacturers, akin to the established norms for gas chromatography mass spectrometry instruments, should standardize the collision energy at 20 eV across different instrument platforms.

8 September 2020 in Science Signaling
Verified
Journal Article
Closed access
CGCarlos Guijas
Carlos Guijas
J. Rafael Montenegro-BurkeJ. Rafael Montenegro-Burke
J. Rafael Montenegro-Burke
RCRigo Cintron-Colon
Rigo Cintron-Colon
Xavier Domingo-AlmenaraXavier Domingo-Almenara
Xavier Domingo-Almenara
MSManuel Sanchez-Alavez
Manuel Sanchez-Alavez
GSGary Siuzdak
Gary Siuzdak
Metabolites that may enable calorie restriction to induce hypothermia and extend health span are identified.

22 January 2021 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
Erica MajumderErica Majumder
Erica Majumder
Elizabeth BillingsElizabeth Billings
Elizabeth Billings
HBH. Paul Benton
H. Paul Benton
RMRichard L. Martin
Richard L. Martin
APAmelia Palermo
Amelia Palermo
GSGary Siuzdak
Gary Siuzdak

27 July 2021 in Analytical Chemistry
Verified
Journal Article
Closed access
JXjingchuan xue
jingchuan xue
RDRico J. E. Derks
Rico J. E. Derks
BWBill Webb
Bill Webb
Elizabeth BillingsElizabeth Billings
Elizabeth Billings
AAAries Aisporna
Aries Aisporna
GSGary Siuzdak
Gary Siuzdak