Ester Barbieri

Ms. Ester Barbieri

University of Bologna, Bologna, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2022 in Construction and Building Materials
Verified
Journal Article
Closed access
EBEster Barbieri
Ester Barbieri
FTFrancesca Trevisiol
Francesca Trevisiol
CPCesare Pizzigatti
Cesare Pizzigatti
Gabriele BitelliGabriele Bitelli
Gabriele Bitelli
Elisa FranzoniElisa Franzoni
Elisa Franzoni

24 August 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
FTFrancesca Trevisiol
Francesca Trevisiol
EBEster Barbieri
Ester Barbieri
Gabriele BitelliGabriele Bitelli
Gabriele Bitelli
The recent improvement of infrared image quality has increased the use of thermography as a non-destructive diagnostic technique. Amongst other applications, thermography can be used to monitor historic buildings. The present work was carried out within the framework of the Horizon 2020 European project SHELTER, which aims to create a management plan for cultural heritage subject to environmental and anthropogenic risk. Among the chosen case studies is the Santa Croce Complex in Ravenna (Italy), which is exposed to different hazards, including flooding. The church has a peculiar architecture that develops below the street level, so the internal walls are affected by the deterioration caused by rising humidity. In such a case of advanced degradation, passive thermography cannot be used to its full potential. For this reason, an innovative methodology involving active thermography was first developed and validated with laboratory tests. Secondly, we conducted its first application to a real case study. With this purpose, an active thermography survey with forced ventilation was carried out to enhance different stages of material degradation by means of automatic classification of multitemporal data. These experiments have resulted in a method using an active thermal survey in a high moisture content environment to detect masonry degradation.


23 July 2024 in Water
Verified
Journal Article
Open access
PDF file
MPMaria Rosaria Pascale
Maria Rosaria Pascale
DRDomenico Simone Roggio
Domenico Simone Roggio
EBEster Barbieri
Ester Barbieri
FMFirst 285 Marino
First 285 Marino
CDCarlo Derelitto
Carlo Derelitto
Sandra CristinoSandra Cristino
Sandra Cristino
The World Health Organization (WHO) recommends the introduction of a water safety plan (WSP) approach on drinking water, in all types of settings. This study represents the first WSP developed on the Neptune Fountain, in Bologna (Italy), based on an interdisciplinary approach, integrating hydraulic and microbiological features, in a Building Information Modeling (BIM). The aim was to develop a dynamic and digital platform to update and share the maintenance program, promoting collaboration among microbiologists, engineers, and municipal staff. Water samples were collected along fountain water distribution systems (WDS) from 2016 to 2021 to monitor water quality through the heterotrophic bacteria at 22 °C and 37 °C, as well as to conduct an Enterococci, Coliform bacteria, Escherichia coli, Pseudomonas aeruginosa, Clostridium perfringens, and Staphylococcus aureus assessment. Simultaneously, hydraulic measures were performed, and advanced geomatics techniques were used to detect the WDS structural components, with a focus on the water treatment system (WTS). The WTS consisted of 10 modules corresponding to specific treatments: descaling, carbon–sand filtration, reverse osmosis, and ultraviolet disinfection. Fecal indicators, heterotrophic bacteria, and P. aeruginosa exceeded the reference limits in most of the modules. Several disinfections and washing treatments, other than changing the maintenance procedure scheduling, were performed, improving the WTS and controlling the contamination. The developed microbiological results, hydraulic measurements, and maintenance procedures were integrated in the BIM model to optimize the data storage, updating procedures and the real-time data sharing. This approach improved the fountain management, operation, and material conservation, ultimately preserving the health of daily visitors.