Fabio Rossi

Dr. Fabio Rossi

Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Piedmont, Italy
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018
Verified
Conference Paper
Closed access
SSStefano Sapienza
Stefano Sapienza
PRPaolo Motto Ros
Paolo Motto Ros
DGDavid Alejandro Fernandez Guzman
David Alejandro Fernandez Guzman
Fabio RossiFabio Rossi
Fabio Rossi
Rossana TerraccianoRossana Terracciano
Rossana Terracciano
DDDanilo Demarchi
Danilo Demarchi
This paper presents a minimum complexity hand movement recognition algorithm based on Average Threshold Crossing (ATC) technique. It exploits the number of threshold-crossing events, generated by a full-custom acquisition board, from the surface ElectroMyoGraphic (sEMG) signals of three forearm muscles to detect four different movements of the wrist: flexion, extension, abduction and grasp. A Support Vector Machine (SVM) model has been trained with the signals acquired from ten subjects, who repeated ten times each gesture. To avoid correlation between training and testing dataset, the Leave One Subject Out (LOSO) cross-validation technique has been chosen. The average ATC classifier's accuracy is 92.87 %, only 5.34 % below the results obtained feeding the same model with the sEMG features extracted from the raw sampled signals. The total latency of the algorithm, from the acquisition to the prediction, is 160 ms. Power consumption was considered too: with less than the power budget for one sampled sEMG channel, it is possible to acquire and transmit (through a Bluetooth low energy module) the event-driven data of four sEMG channels, with an effective data rate of only 28 B /s. Obtained performance makes this technique suited for wearable systems or Internet-of-Things (IoT) applications.

3 October 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
Andrea MongardiAndrea Mongardi
Andrea Mongardi
Fabio RossiFabio Rossi
Fabio Rossi
Andrea PrestiaAndrea Prestia
Andrea Prestia
PRPaolo Motto Ros
Paolo Motto Ros
Massimo Ruo RochMassimo Ruo Roch
Massimo Ruo Roch
DDDanilo Demarchi
Danilo Demarchi
Hand gesture recognition has recently increased its popularity as Human-Machine Interface (HMI) in the biomedical field. Indeed, it can be performed involving many different non-invasive techniques, e.g., surface ElectroMyoGraphy (sEMG) or PhotoPlethysmoGraphy (PPG). In the last few years, the interest demonstrated by both academia and industry brought to a continuous spawning of commercial and custom wearable devices, which tried to address different challenges in many application fields, from tele-rehabilitation to sign language recognition. In this work, we propose a novel 7-channel sEMG armband, which can be employed as HMI for both serious gaming control and rehabilitation support. In particular, we designed the prototype focusing on the capability of our device to compute the Average Threshold Crossing (ATC) parameter, which is evaluated by counting how many times the sEMG signal crosses a threshold during a fixed time duration (i.e., 130 ms), directly on the wearable device. Exploiting the event-driven characteristic of the ATC, our armband is able to accomplish the on-board prediction of common hand gestures requiring less power w.r.t. state of the art devices. At the end of an acquisition campaign that involved the participation of 26 people, we obtained an average classifier accuracy of 91.9% when aiming to recognize in real time 8 active hand gestures plus the idle state. Furthermore, with 2.92mA of current absorption during active functioning and 1.34mA prediction latency, this prototype confirmed our expectations and can be an appealing solution for long-term (up to 60 h) medical and consumer applications.

9 August 2021 in IEEE Sensors Journal
Verified
Journal Article
Open access
Fabio RossiFabio Rossi
Fabio Rossi
Andrea MongardiAndrea Mongardi
Andrea Mongardi
PRPaolo Motto Ros
Paolo Motto Ros
Massimo Ruo RochMassimo Ruo Roch
Massimo Ruo Roch
MMMaurizio Martina
Maurizio Martina
DDDanilo Demarchi
Danilo Demarchi
Device wearability and operating time are trending topics in recent state-of-art works on surface ElectroMyoGraphic (sEMG) muscle monitoring. No optimal trade-off, able to concurrently address several problems of the acquisition system like robustness, miniaturization, versatility, and power efficiency, has yet been found. In this tutorial we present a solution to most of these issues, embedding in a single device both an sEMG acquisition channel, with our custom event-driven hardware feature extraction technique (named Average Threshold Crossing), and a digital part, which includes a microcontroller unit, for (optionally) sEMG sampling and processing, and a Bluetooth communication, for wireless data transmission. The knowledge acquired by the research group brought to an accurate selection of each single component, resulting in a very efficient prototype, with a comfortable final size (57.8mm x 25.2mm x 22.1mm) and a consistent signal-to-noise ratio of the acquired sEMG (higher than 15 dB). Furthermore, a precise design of the firmware has been performed, handling both signal acquisition and Bluetooth transmission concurrently, thanks to a FreeRTOS custom implementation. In particular, the system adapts to both sEMG and ATC transmission, with an application throughput up to 2 kB s-1 and an average operating time of 80 h (for high resolution sEMG sampling), relaxable to 8Bs-1 throughput and about 230 h operating time (considering a 110mAh battery), in case of ATC acquisition only. Here we share our experience over the years in designing wearable systems for the sEMG detection, specifying in detail how our event-driven approach could benefit the device development phases. Some previous basic knowledge about biosignal acquisition, electronic circuits and programming would certainly ease the repeatability of this tutorial.

10 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Fabio RossiFabio Rossi
Fabio Rossi
PRPaolo Motto Ros
Paolo Motto Ros
RRRicardo Rosales
Ricardo Rosales
DDDanilo Demarchi
Danilo Demarchi
The analysis of the surface ElectroMyoGraphic (sEMG) signal for controlling the Functional Electrical Stimulation (FES) therapy is being widely accepted as an active rehabilitation technique for the restoration of neuro-muscular disorders. Portability and real-time functionalities are major concerns, and, among others, two correlated challenges are the development of an embedded system and the implementation of lightweight signal processing approaches. In this respect, the event-driven nature of the Average Threshold Crossing (ATC) technique, considering its high correlation with the muscle force and the sparsity of its representation, could be an optimal solution. In this paper we present an embedded ATC-FES control system equipped with a multi-platform software featuring an easy-to-use Graphical User Interface (GUI). The system has been first characterized and validated by analyzing CPU and memory usage in different operating conditions, as well as measuring the system latency (fulfilling the real-time requirements with a 140 ms FES definition process). We also confirmed system effectiveness, testing it on 11 healthy subjects: The similarity between the voluntary movement and the stimulate one has been evaluated, computing the cross-correlation coefficient between the angular signals acquired during the limbs motion. We obtained high correlation values of 0.87 ± 0.07 and 0.93 ± 0.02 for the elbow flexion and knee extension exercises, respectively, proving good stimulation application in real therapy-scenarios.

20 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Fabio RossiFabio Rossi
Fabio Rossi
FSFederica Savi
Federica Savi
Andrea PrestiaAndrea Prestia
Andrea Prestia
Andrea MongardiAndrea Mongardi
Andrea Mongardi
DDDanilo Demarchi
Danilo Demarchi
GBGiovanni Buccino
Giovanni Buccino
Action observation treatment (AOT) exploits a neurophysiological mechanism, matching an observed action on the neural substrates where that action is motorically represented. This mechanism is also known as mirror mechanism. In a typical AOT session, one can distinguish an observation phase and an execution phase. During the observation phase, the patient observes a daily action and soon after, during the execution phase, he/she is asked to perform the observed action at the best of his/her ability. Indeed, the execution phase may sometimes be difficult for those patients where motor impairment is severe. Although, in the current practice, the physiotherapist does not intervene on the quality of the execution phase, here, we propose a stimulation system based on neurophysiological parameters. This perspective article focuses on the possibility to combine AOT with a brain–computer interface system (BCI) that stimulates upper limb muscles, thus facilitating the execution of actions during a rehabilitation session. Combining a rehabilitation tool that is well-grounded in neurophysiology with a stimulation system, such as the one proposed, may improve the efficacy of AOT in the treatment of severe neurological patients, including stroke patients, Parkinson’s disease patients, and children with cerebral palsy.

1 November 2019
Verified
Conference Paper
Closed access
Andrea MongardiAndrea Mongardi
Andrea Mongardi
PRPaolo Motto Ros
Paolo Motto Ros
Fabio RossiFabio Rossi
Fabio Rossi
Massimo Ruo RochMassimo Ruo Roch
Massimo Ruo Roch
MMMaurizio Martina
Maurizio Martina
DDDanilo Demarchi
Danilo Demarchi
Latency and power consumption management are present-day hot topics for wearable devices and IoT applications. This paper presents the implementation of a low power system for hand movement recognition, based on surface ElectroMyo-Graphic (sEMG) signals, suitable for human-machine interface. Every time the sEMG signal crosses a predefined threshold an event is generated, implementing the Average Threshold Crossing (ATC) technique directly on-boards on the subject arm. Resulting quasi-digital signals, averaged over a fixed time window, are sent to an ARM Cortex-M4F processor which implements a fully-connected Neural Network (NN) able to recognize six different gestures from only three input channels. Dataset creation has involved 25 healthy people, each one performing five movements within five repeated sessions. The NN has been trained using the per-subject holdout validation method, obtaining an accuracy of 96.34%. With a maximum latency of 8.5 ms and an average power consumption of only 0.8 mW at full recognition rate, the proposed NN implementation shows promising results.