László Ádám Fazekas

Dr. László Ádám Fazekas

University of Debrecen, Debrecen, Hajdú-Bihar, Hungary
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2020 in Injury
Verified
Journal Article
Open access
PDF file
BSBalazs Szabo
Balazs Szabo
LFLászló Ádám Fazekas
László Ádám Fazekas
SGSouleiman Ghanem
Souleiman Ghanem
ZGZoltan A. Godo
Zoltan A. Godo
JMJozsef Madar
Jozsef Madar
Norbert NemethNorbert Nemeth
Norbert Nemeth
: The biomechanical properties of small vessels and microvascular anastomoses have not been studied completely yet. However, in case of vascular injury and various microsurgical reconstructive procedures a safe anastomosis is essential. Quick and reliable tests are needed to test various anastomoses in research and in teaching courses as well for quality control and proper feedback. We aimed to compare selected biomechanical properties of the simple interrupted, the continuous suture and the modified Lauritzen's sleeve-technique. : Sixty femoral arteries from chicken thigh biopreparates and 12 abdominal aortas from rats were used in this study. In case of the pressure resistance test the groups were: the simple interrupted, the continuous suture and the modified Lauritzen's sleeve-technique. The tensile-strength, elongation and elasticity measurement groups were the simple interrupted and continuous sutures with 8 and 12 stitches. Furthermore the suture materials in various conditions (simple thread, knotted threads, stitch with intact and damaged threads) were also compared. The tensile-strength and the pressure probe devices were custom made in cooperation with the Faculty of Informatics. : The average diameter of the chicken femoral arteries was 3.25±0.38 mm. The sleeve-technique showed the biggest pressure drop (56±16.41 mmHg), however, it was the fastest method. The tensile-strength of simple interrupted suture was 4.55±0.7 Newton (N), being lower than of the intact vessel (6.8±1.4 N). The tensile-strength did not differ significantly between the 12-stitch simple interrupted and continuous sutures, however, the latter was stronger. The anastomoses made on thread model were significantly stronger than the ones on vessels. : The main variables were the number of stitches and the strength of the vessel. The pressure drop was not correlated with the stitch number. One incorrect stitch can dramatically increase the leakage. Although the sleeve-technique is quick to be performed, it cannot withstand high pressure. The suture material itself is far stronger then the vessel. The vessel tensile strength was decreased in the anastomoses. For the given vessel diameter more than 8 stitches should be used.

26 February 2023 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
BBBrigitta Bernát
Brigitta Bernát
RERita Erdelyi Rita Erdelyi
Rita Erdelyi Rita Erdelyi
LFLászló Ádám Fazekas
László Ádám Fazekas
GGGréta Garami
Gréta Garami
RSReka Szekeres
Reka Szekeres
DPDaniel Priksz
Daniel Priksz
Multi-target drug candidate BGP-15 has shown cardioprotective and antiarrhythmic actions in diseased models. Here, we investigated the effects of BGP-15 on ECG and echocardiographic parameters, heart rate variability (HRV), and arrhythmia incidence in telemetry-implanted rats, under beta-adrenergic stimulation by isoproterenol (ISO). In total, 40 rats were implanted with radiotelemetry transmitters. First, dose escalation studies (40–160 mg/kg BGP-15), ECG parameters, and 24 h HRV parameters were assessed. After, rats were divided into Control, Control+BGP-15, ISO, and ISO+BGP-15 subgroups for 2 weeks. ECG recordings were obtained from conscious rats, arrhythmias and HRV parameters were assessed, and echocardiography was carried out. ISO-BGP-15 interaction was also evaluated on an isolated canine cardiomyocyte model. BGP-15 had no observable effects on the ECG waveforms; however, it decreased heart rate. HRV monitoring showed that BGP-15 increased RMSSD, SD1, and HF% parameters. BGP-15 failed to counteract 1 mg/kg ISO-induced tachycardia, but diminished the ECG of ischemia and suppressed ventricular arrhythmia incidence. Under echocardiography, after low-dose ISO injection, BGP-15 administration lowered HR and atrial velocities, and increased end-diastolic volume and ventricle relaxation, but did not counteract the positive inotropic effects of ISO. Two weeks of BGP-15 treatment also improved diastolic function in ISO-treated rats. In isolated cardiomyocytes, BGP-15 prevented 100 nM ISO-induced aftercontractions. Here, we show that BGP-15 increases vagally mediated HRV, reduces arrhythmogenesis, enhances left ventricle relaxation, and suppresses the aftercontractions of cardiomyocytes. As the drug is well tolerated, it may have a clinical value in preventing fatal arrhythmias.

Verified
Journal Article
Open access
PDF file
LFLászló Ádám Fazekas
László Ádám Fazekas
BSBalazs Szabo
Balazs Szabo
VSVince Szegeczki
Vince Szegeczki
CFCsaba Filler
Csaba Filler
AVAdam Varga
Adam Varga
Norbert NemethNorbert Nemeth
Norbert Nemeth
The proper regeneration of vessel anastomoses in microvascular surgery is crucial for surgical safety. Pituitary adenylate cyclase-activating polypeptide (PACAP) can aid healing by decreasing inflammation, apoptosis and oxidative stress. In addition to hematological and hemorheological tests, we examined the biomechanical and histological features of vascular anastomoses with or without PACAP addition and/or using a hemostatic sponge (HS). End-to-end anastomoses were established on the right femoral arteries of rats. On the 21st postoperative day, femoral arteries were surgically removed for evaluation of tensile strength and for histological and molecular biological examination. Effects of PACAP were also investigated in tissue culture in vitro to avoid the effects of PACAP degrading enzymes. Surgical trauma and PACAP absorption altered laboratory parameters; most notably, the erythrocyte deformability decreased. Arterial wall thickness showed a reduction in the presence of HS, which was compensated by PACAP in both the tunica media and adventitia in vivo. The administration of PACAP elevated these parameters in vitro. In conclusion, the application of the neuropeptide augmented elastin expression while HS reduced it, but no significant alterations were detected in collagen type I expression. Elasticity and tensile strength increased in the PACAP group, while it decreased in the HS decreased. Their combined use was beneficial for vascular regeneration.

12 April 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
VSVince Szegeczki
Vince Szegeczki
LFLászló Ádám Fazekas
László Ádám Fazekas
MKMáté Kulcsár
Máté Kulcsár
DRDora Reglodi
Dora Reglodi
PTPéter Török
Péter Török
JTJuhasz Tamas
Juhasz Tamas
Endometriosis is a chronic gynecological disease that causes numerous severe symptoms in affected women. Revealing alterations of the molecular processes in ectopic endometrial tissue is the current policy for understanding the pathomechanisms and discovering potential novel therapeutic targets. Examining molecular processes of eutopic endometrium is likely to be a convenient method to compare it with the molecular alterations observed in ectopic tissues. The aim of the present study was to determine what proportion of the surgically resected eutopic endometrial samples is suitable for further experiments so that these can be comparable with endometriosis. Final hospital reports and histopathology reports of a 3-year-long period (1162 cases) were analysed. The application of a retrospective screening method promoted the categorization of these cases, and quantification of the categorized cases was accomplished. In addition, results obtained from cultured endometrium samples were also detailed. Only a small number of the harvested endometrial samples was suitable for further molecular analysis, while preoperative screening protocol could enlarge this fraction. Applying clinical and histopathological selection and exclusion criteria for tissue screening and histopathological examination of samples could ensure the comparability of healthy endometrium with endometriosis. The present study could be useful for researchers who intend to perform molecular experiments to compare endometriosis with the physiological processes of the endometrium.

25 June 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
BSBalazs Szabo
Balazs Szabo
BGBalazs Gasz
Balazs Gasz
LFLászló Ádám Fazekas
László Ádám Fazekas
AVAdam Varga
Adam Varga
LKLevente Kiss-Pápai
Levente Kiss-Pápai
Norbert NemethNorbert Nemeth
Norbert Nemeth
Vascular graft maturation is associated with blood flow characteristics, such as velocity, pressure, vorticity, and wall shear stress (WSS). Many studies examined these factors separately. We aimed to examine the remodeling of arterio-venous fistulas (AVFs) and loop-shaped venous interposition grafts, together with 3D flow simulation. Thirty male Wistar rats were randomly and equally divided into sham-operated, AVF, and loop-shaped venous graft (Loop) groups, using the femoral and superficial inferior epigastric vessels for anastomoses. Five weeks after surgery, the vessels were removed for histological evaluation, or plastic castings were made and scanned for 3D flow simulation. Remodeling of AVF and looped grafts was complete in 5 weeks. Histology showed heterogeneous morphology depending on the distribution of intraluminal pressure and WSS. In the Loop group, an asymmetrical WSS distribution coincided with the intima hyperplasia spots. The tunica media was enlarged only when both pressure and WSS were high. The 3D flow simulation correlated with the histological findings, identifying “hotspots” for intimal hyperplasia formation, suggesting a predictive value. These observations can be useful for microvascular research and for quality control in microsurgical training.

15 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ZGZoltan Attila Godo
Zoltan Attila Godo
LFLászló Ádám Fazekas
László Ádám Fazekas
GFGergo Fritsch
Gergo Fritsch
BSBalazs Szabo
Balazs Szabo
Norbert NemethNorbert Nemeth
Norbert Nemeth
Optimizing the regeneration process of surgically created anastomoses (blood vessels, intestines, nerves) is an important topic in surgical research. One of the most interesting parameter groups is related to the biomechanical properties of the anastomoses. Depending on the regeneration process and its influencing factors, tensile strength and other biomechanical features may change during the healing process. Related to the optimal specimen size, the range and accuracy of measurements, and applicability, we have developed a custom-tailored microcontroller-based device. In this paper, we describe the hardware and software configuration of the latest version of the device, including experiences and comparative measurements of tensile strength and elasticity of artificial materials and biopreparate tissue samples. The machine we developed was made up of easily obtainable parts and can be easily reproduced on a low budget. The basic device can apply a force of up to 40 newtons, and can grasp a 0.05–1 cm wide, 0.05–1 cm thick tissue. The length of the test piece on the rail should be between 0.3 and 5 cm. Low production cost, ease of use, and detailed data recording make it a useful tool for experimental surgical research.