Flynn Darby

Mr. Flynn Darby

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MHMichael Y. Hua
Michael Y. Hua
FDFlynn Darby
Flynn Darby
JHJesson D. Hutchinson
Jesson D. Hutchinson
GMGeorge E. McKenzie
George E. McKenzie
SCShaun D. Clarke
Shaun D. Clarke
SPSara A. Pozzi
Sara A. Pozzi

26 January 2024 in Journal of Nuclear Engineering
Verified
Journal Article
Open access
PDF file
OPOskari V Pakari
Oskari V Pakari
ALAndrew Lucas
Andrew Lucas
FDFlynn Darby
Flynn Darby
VLVincent P. Lamirand
Vincent P. Lamirand
TMTessa Maurer
Tessa Maurer
SPSara A. Pozzi
Sara A. Pozzi
Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

29 November 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
FDFlynn Darby
Flynn Darby
OPOskari V Pakari
Oskari V Pakari
MHMichael Y. Hua
Michael Y. Hua
VLVincent Lamirand
Vincent Lamirand
SCShaun D. Clarke
Shaun D. Clarke
SPSara A. Pozzi
Sara A. Pozzi
Noise measurements in light water reactor systems aid in generating validation data for integral point kinetic parameter predictions and generating monitoring parameters for reactor safety and safeguards. The CROCUS zero-power reactor has been used to support both efforts via measurements with thermal neutron detectors to observe neutron noise and inorganic scintillators to observe gamma noise. The cross-correlation of gamma and neutron noise has been investigated at CROCUS with separate gamma-only and neutron-only detectors. Organic scintillators, sensitive to both neutrons and gamma rays, can be used to cross-correlate gamma-ray and neutron noise with a single detector type. Herein, we present noise measurements using organic scintillators in a light-water, zero-power research reactor for the first time. We discuss data obtained with two 5.08 cm-length by 5.08 cm-diameter cylindrical trans-stilbene detectors and two 6-mm cubic scintillators – one trans-stilbene and one organic glass – set in the water reflector of CROCUS and outside the reactor vessel. The prompt neutron decay constant was estimated to be α CPSD = (154 ± 1) s -1 at 3 mW critical from the (γ,γ) signal, which agrees within one standard deviation overlap with previous measurements with CeBr 3 and simulation in Serpent 2. The (n,n) estimate of α CPSD = (145 ± 23) s -1 at 3 mW critical lacked precision but agreed within one standard deviation overlap with previous 235 U fission chamber estimates and simulation in Serpent 2. The 6-mm cubic scintillators were too inefficient to estimate α, but informed possible small-cell, high-volume detection systems to improve the (n,n) estimate capabilities. Based on the high precision estimate of α from the (γ,γ) CPSD signal we suggest the further development of theory to calculate β eff and Λ from gamma-ray noise measurements and recommend gamma noise measurements for future simulation validation and as a method of reactor monitoring.

9 March 2023 in Nuclear Science and Engineering
Verified
Journal Article
Open access
IPImre Pázsit
Imre Pázsit
VDVictor Dykin
Victor Dykin
FDFlynn Darby
Flynn Darby
In recent work, we extended the methodology of multiplicity counting in nuclear safeguards by elaborating the one-speed stochastic transport theory of the calculation of the so-called multiplicity moments, i.e., the factorial moments of the number of neutrons emitted from a fissile item, following a source event from an internal neutron source [spontaneous fission and ( α,n) reactions]. Calculations were made for solid spheres and cylinders, with the source being homogeneously distributed within the item. Recent measurements of the Rocky Flats Shells during the Measurement of Uranium Subcritical and Critical (MUSIC) campaign conducted by Los Alamos National Laboratory and assisted by the University of Michigan inspired us to extend the model to spherical shell geometry with a point source in the middle of the central cavity. Comparison of the calculated results with the experimental ones indicated that accounting for fission as the only neutron reaction (the standard procedure in the point model, adapted also in our work so far) was not sufficient for reaching good agreement with measurements. The model was therefore extended to include elastic scattering into the one-speed formalism, whereas the effect of inelastic scattering was accounted for in an empirical way. After these extensions, good agreement was found between the calculated and the measured values. The paper describes the extension of the theory and provides concrete quantitative results.

1 November 2023 in American Journal of Physics
Verified
Journal Article
Open access
PDF file
FDFlynn Darby
Flynn Darby
MHMichael Y. Hua
Michael Y. Hua
OPOskari V. Pakari
Oskari V. Pakari
SCShaun D. Clarke
Shaun D. Clarke
SPSara A. Pozzi
Sara A. Pozzi
In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

24 January 2025 in Nuclear Science and Engineering
Verified
Journal Article
Open access
FDFlynn Darby
Flynn Darby
STSchuyler J. Tyler
Schuyler J. Tyler
OPOskari V Pakari
Oskari V Pakari
VLVincent P. Lamirand
Vincent P. Lamirand
SCShaun D. Clarke
Shaun D. Clarke
SPSara A. Pozzi
Sara A. Pozzi