Francesca Orsola Alfano

Dr. Francesca Orsola Alfano

DIMES, University of Calabria, Cosenza, Italy
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Powder Technology
Verified
Journal Article
Closed access
Francesca Orsola AlfanoFrancesca Orsola Alfano
Francesca Orsola Alfano
ARAlberto Di Renzo
Alberto Di Renzo
FMFrancesco Paolo Di Maio
Francesco Paolo Di Maio
MGMojtaba Ghadiri
Mojtaba Ghadiri

1 May 2018 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
UZU. Zafar
U. Zafar
Francesca Orsola AlfanoFrancesca Orsola Alfano
Francesca Orsola Alfano
MGMojtaba Ghadiri
Mojtaba Ghadiri
In a number of applications, especially in pharmaceutical drug development, there is often a very small powder quantity available for evaluating the manufacturability of new drugs. However, it is highly desirable to be able to quickly evaluate processing issues, and where possible using the smallest powder quantity. In the present work, a proprietary commercial powder dispersion device (the disperser of Malvern© Morphologi G3) is adapted to evaluate the triboelectric charging tendency. A very small powder quantity (as small as 0.1 mg) is dispersed by a pressure pulse of compressed gas such as air or nitrogen. This causes the particles to become air borne and collide with the containing walls, resulting in dispersion and leading to triboelectric charge transfer between the particles and the walls. In this work, the charging propensity of a number of materials is evaluated and the effect of particle surface functional groups on the tribo-electric charge transfer is analysed. Model materials with a well-defined shape (glass ballotini) but with different silane groups deposited on their surfaces as well as a number of organic crystalline particles (such as aspirin, α-lactose monohydrate and paracetamol) are tested. Following dispersion the particles move immediately to a Faraday cup placed directly underneath the disperser. Therefore, particle charge is measured with no decay. The method can differentiate charging of different polymorphs of the same material, different silane groups on the surfaces of glass ballotini and different crystal morphologies obtained from crystallisation from various solvents.

30 July 2022 in Powder Technology
Verified
Journal Article
Closed access
Francesca Orsola AlfanoFrancesca Orsola Alfano
Francesca Orsola Alfano
FMF.P. Di Maio
F.P. Di Maio
ARA. Di Renzo
A. Di Renzo

30 October 2022 in Advanced Powder Technology
Verified
Journal Article
Closed access
Francesca Orsola AlfanoFrancesca Orsola Alfano
Francesca Orsola Alfano
MSMartin Sommerfeld
Martin Sommerfeld
FMFrancesco Paolo Di Maio
Francesco Paolo Di Maio
ARAlberto Di Renzo
Alberto Di Renzo

18 October 2021 in Industrial & Engineering Chemistry Research
Verified
Journal Article
Closed access
Francesca Orsola AlfanoFrancesca Orsola Alfano
Francesca Orsola Alfano
ABAndrea Benassi
Andrea Benassi
RGRoberto Gaspari
Roberto Gaspari
Alberto Di RenzoAlberto Di Renzo
Alberto Di Renzo
FMFrancesco Paolo Di Maio
Francesco Paolo Di Maio

18 June 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Francesca Orsola AlfanoFrancesca Orsola Alfano
Francesca Orsola Alfano
Alberto Di RenzoAlberto Di Renzo
Alberto Di Renzo
Francesco P. Di MaioFrancesco P. Di Maio
Francesco P. Di Maio
The generation and accumulation of an electrostatic charge from handling pharmaceutical powders is a well-known phenomenon, given the insulating nature of most APIs (Active Pharmaceutical Ingredients) and excipients. In capsule-based DPIs (Dry Powder Inhalers), the formulation is stored in a gelatine capsule placed in the inhaler just before inhalation. The action of capsule filling, as well as tumbling or vibration effects during the capsule life cycle, implies a consistent amount of particle–particle and particle–wall contacts. A significant contact-induced electrostatic charging can then take place, potentially affecting the inhaler’s efficiency. DEM (Discrete Element Method) simulations were performed on a carrier-based DPI formulation (salbutamol–lactose) to evaluate such effects. After performing a comparison with the experimental data on a carrier-only system under similar conditions, a detailed analysis was conducted on two carrier–API configurations with different API loadings per carrier particle. The charge acquired by the two solid phases was tracked in both the initial particle settling and the capsule shaking process. Alternating positive–negative charging was observed. Particle charging was then investigated in relation to the collision statistics, tracking the particle–particle and particle–wall events for the carrier and API. Finally, an analysis of the relative importance of electrostatic, cohesive/adhesive, and inertial forces allowed the importance of each term in determining the trajectory of the powder particles to be estimated.