Francesca Tuci

Mrs. Francesca Tuci

Civil and Environmental Engineering, University of Florence, Florence, Tuscany, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2022 in Waste Management
Verified
Journal Article
Open access
MŚMaciej Śliz
Maciej Śliz
Francesca TuciFrancesca Tuci
Francesca Tuci
KCK. Czerwińska
K. Czerwińska
SFS. Fabrizi
S. Fabrizi
LLL. Lombardi
L. Lombardi
MWM. Wilk
M. Wilk
Mixed municipal solid waste (MSW) may be pre-treated in a mechanical-biological treatment (MBT) plant to produce an exiting stream with improved combustible characteristics. The process also produces a second waste stream, which is generally separated on a size basis by industrial sieving equipment. It contains fractions with a high moisture content such as residual food waste, soiled paper and cardboard, and small fragments of other materials. Samples of this stream, collected at an existing plant, were characterized and processed by hydrothermal carbonization (HTC) at laboratory scale, at various temperatures (180, 200 and 220 °C), reaction times (1, 4 and 8 h) and solid to water ratios (0.15 and 0.07). The primary energy balance, on a hypothetical industrial scale, was performed. In brief, the results confirmed that the produced hydrochar was a brittle, hydrophobic, solid carbonaceous product which gave a better combustion performance as the residence time of the HTC process was increased. Moreover, the dewaterability of the carbonized waste was greatly improved when compared to raw, wet samples. The results of the primary energy balance confirmed that the energy contained in the produced hydrochar was higher than the energy consumption for the process itself, under all the HTC working conditions. The energy consumed in the process was in the range of 40-70 % of the energy content of the produced hydrochar.
1

10 May 2023 in Waste Management
Verified
Journal Article
Closed access
Lidia LombardiLidia Lombardi
Lidia Lombardi
Francesca TuciFrancesca Tuci
Francesca Tuci
MŚMaciej Śliz
Maciej Śliz
KCKlaudia Czerwińska
Klaudia Czerwińska
SFSimone Fabrizi
Simone Fabrizi
Małgorzata WilkMałgorzata Wilk
Małgorzata Wilk

9 January 2025 in Membranes
Verified
Journal Article
Open access
PDF file
Francesca TuciFrancesca Tuci
Francesca Tuci
MAMichele Allocca
Michele Allocca
DFDonatella Fibbi
Donatella Fibbi
DDDaniele Daddi
Daniele Daddi
Riccardo GoriRiccardo Gori
Riccardo Gori
The textile district of Prato (Italy) has developed a wastewater recycling system of considerable scale. The reclaimed wastewater is characterized by high levels of hardness (32 °F on average), which precludes its direct reuse in numerous wet textile processes (e.g., textile dyeing). Consequently, these companies utilize ion exchange resins for water softening. However, the regeneration of the resins results in an increased concentration of chlorides in the reclaimed wastewater that exceeds the limit set by Italian regulations for the reuse of water for irrigation purposes. The objective of this study is to investigate the potential of membrane filtration as an alternative method for removing hardness from water. Therefore, an industrial-scale ultrafiltration-nanofiltration (UF-NF) pilot plant was installed to test the rejection of hardness from the reclaimed wastewater. The experiment employed two types of NF membranes and three permeate fluxes (27, 35, and 38 L·m−2·h−1) for testing. The results demonstrated that the system could remove hardness with efficiencies exceeding 98% under all conditions tested. The experimental findings indicate that the UF-NF system has the potential to be employed as a post-treatment step to render the reclaimed wastewater suitable for all textile finishing processes and to expand the scope for reuse.

5 November 2024 in Water
Verified
Journal Article
Open access
PDF file
Francesca TuciFrancesca Tuci
Francesca Tuci
AAAlexandra Antal
Alexandra Antal
SDSaer Doumett
Saer Doumett
DFDonatella Fibbi
Donatella Fibbi
RCRoberto Camisa
Roberto Camisa
Riccardo GoriRiccardo Gori
Riccardo Gori
Heavy metals represent a significant hazard in textile wastewater, posing a considerable risk to both the ecosystem and human health. The objective of this study was to analyze the removal efficiency of specific heavy metals in a large wastewater treatment plant (WWTP) located in Prato (Tuscany, Italy), where the main Italian textile district is based. To achieve this, the mass balance calculation approach was employed. Therefore, two monitoring campaigns were conducted, collecting wastewater and sludge samples in some specific sections of the WWTP. The concentrations of Pb, Cd, Ni, As, and Sn were consistently below the detection limits. A good removal efficiency was determined for Zn, Cu, Ba, Crtot, and Sb, in the range of 37–79%. These metals are predominantly present in particulate form, facilitating their removal through sedimentation. Conversely, boron is largely present in the dissolved phase, resulting in its complete release through the treated effluent. Subsequently, an excellent linear correlation was identified between the input load and the contaminant load removed. This demonstrated that the plant’s efficiency remains unaffected by an increase in the input load at the observed contaminant concentrations. Finally, a probability law was identified that demonstrates an excellent degree of approximation in representing inlet metal concentrations. The findings of this study indicate that the treatment systems employed by the WWTP are capable of effectively removing heavy metals.

14 May 2024 in Membranes
Verified
Journal Article
Open access
PDF file
LPLaura Palli
Laura Palli
Francesca TuciFrancesca Tuci
Francesca Tuci
LFLetizia Macellaro La Franca
Letizia Macellaro La Franca
DFDonatella Fibbi
Donatella Fibbi
Riccardo GoriRiccardo Gori
Riccardo Gori
This paper describes a case study involving a revamping of a full-scale membrane bioreactor that treats landfill leachate and other liquid wastes. The main change was the introduction of nitritation/denitritation in alternating cycles instead of the classic denitrification/nitrification process, together with the installation of fine bubble diffusers, a reduction in the volume of the biological compartment, and an increase in the equalization volume. The most significant results were obtained for the biological compartment, with a decrease in the specific energy consumption of 46.6%. At the same time, the removal efficiency of COD, BOD, and TN substantially remained the same before and after plant revamping, while the removal efficiency of TP increased over the years, reaching an average value of almost 71%. Regarding the ultrafiltration unit, the specific flux (or permeability) was characterized by an increasing trend. At the same time, the specific energy consumption of this section decreased by 9.4%. These results led to the conclusion that the changes introduced with the revamp led to a more stable process, a reduction in membrane fouling, and important energy savings.

10 March 2025 in Recycling
Verified
Journal Article
Open access
PDF file
MBMassimiliano Boccarossa
Massimiliano Boccarossa
Lidia LombardiLidia Lombardi
Lidia Lombardi
Fabio TatànoFabio Tatàno
Fabio Tatàno
AFAdele Folino
Adele Folino
VSValentina Spadi
Valentina Spadi
PSPiero Sirini
Piero Sirini
The COVID-19 pandemic posed challenges to pre-crisis waste management systems. In this study, two sequential scenarios were identified and compared to investigate the quantitative and environmental impacts of COVID-19 induced changes in the generation and management of residual municipal waste (RMW) in two provincial territories (PTPU, PTMC) of the Marche region (Central Italy, Adriatic Sea side). The pandemic implied, in 2020 (COVID-19 scenario), quantitative reductions in RMW compared to the preceding year, 2019 (Pre-COVID-19 scenario), which were limited to −3.9 and −1.9% in PTPU and PTMC, respectively. Life cycle assessment (LCA) results showed that adapted RMW management practices in 2020 (COVID-19 scenario) improved all the considered environmental indicators in PTMC, compared to the preceding year, 2019 (Pre-COVID-19 scenario), and most of them in PTPU, with the exception of climate change (CC), human toxicity, non-cancer (HTnc), and eutrophication, marine (Em). The hypothetical option of waste-to-energy (WtE) for the RMW, originally destined for direct landfilling in 2020 (COVID-19 scenario), would have represented a safe and environmentally sound option in terms of health protection and CC indicator.