Francesco Sartorio

Dr. Francesco Sartorio

orcid
Adjunct Professor in the Bachelor’s Degree Program in Physio...

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Journal of Orthopaedic & Sports Physical Therapy
Verified
Journal Article
Closed access
FFFranco Franchignoni
Franco Franchignoni
SVStefano Vercelli
Stefano Vercelli
AGAndrea Giordano
Andrea Giordano
FSFrancesco Sartorio
Francesco Sartorio
EBElisabetta Bravini
Elisabetta Bravini
GFGiorgio Ferriero
Giorgio Ferriero
Study Design: Prospective, single-group observational design. Objectives: To determine the minimal clinically important difference (MCID) for the Disabilities of the Arm, Shoulder and Hand (DASH) outcome measure and its shortened version (QuickDASH) in patients with upper-limb musculoskeletal disorders, using a triangulation of distribution- and anchor-based approaches. Background: Meaningful threshold change values of outcome tools are crucial for the clinical decision-making process. Methods: The DASH and QuickDASH were administered to 255 patients (mean ± SD age, 49 ± 15 years; 156 women) before and after a physical therapy program. The external anchor administered after the program was a 7-point global rating of change scale. Results: The test-retest reliability of the DASH and QuickDASH was high (intraclass correlation coefficient model 2,1 = 0.93 and 0.91, respectively; n = 30). The minimum detectable change at the 90% confidence level was 10.81 points for the DASH and 12.85 points for the QuickDASH. After triangulation of these results with those of the mean-change approach and receiver-operating-characteristic-curve analysis, the following MCID values were selected: 10.83 points for the DASH (sensitivity, 82%; specificity, 74%) and 15.91 points for the QuickDASH (sensitivity, 79%; specificity, 75%). After treatment, the MCID threshold was reached/surpassed by 61% of subjects using the DASH and 57% using the QuickDASH. Conclusion: The MCID values from this study for the DASH (10.83 points) and the QuickDASH (15.91 points) could represent the lower boundary for a range of MCID values (reasonably useful for different populations and contextual characteristics). The upper boundary may be represented by the 15 points for the DASH and 20 points for the QuickDASH proposed by the DASH website. J Orthop Sports Phys Ther 2014;44(1):30–39. Epub 30 October 2013. doi:10.2519/jospt.2014.4893

1 June 2013 in International Journal of Rehabilitation Research
Verified
Journal Article
Closed access
GFGiorgio Ferriero
Giorgio Ferriero
SVStefano Vercelli
Stefano Vercelli
FSFrancesco Sartorio
Francesco Sartorio
SLSusana Muñoz Lasa
Susana Muñoz Lasa
EIElena Ilieva
Elena Ilieva
CFCalogero Foti
Calogero Foti
The aim of this study was to assess the reliability of a smartphone-based application developed for photographic-based goniometry, DrGoniometer (DrG), by comparing its measurement of the knee joint angle with that made by a universal goniometer (UG). Joint goniometry is a common mode of clinical assessment used in many disciplines, in particular in rehabilitation. One validated method is photographic-based goniometry, but the procedure is usually complex: the image has to be downloaded from the camera to a computer and then edited using dedicated software. This disadvantage may be overcome by the new generation of mobile phones (smartphones) that have computer-like functionality and an integrated digital camera. This validation study was carried out under two different controlled conditions: (i) with the participant to measure in a fixed position and (ii) with a battery of pictures to assess. In the first part, four raters performed repeated measurements with DrG and UG at different knee joint angles. Then, 10 other raters measured the knee at different flexion angles ranging 20-145° on a battery of 35 pictures taken in a clinical setting. The results showed that inter-rater and intra-rater correlations were always more than 0.958. Agreement with the UG showed a width of 18.2° [95% limits of agreement (LoA)=-7.5/+10.7°] and 14.1° (LoA=-6.6/+7.5°). In conclusion, DrG seems to be a reliable method for measuring knee joint angle. This mHealth application can be an alternative/additional method of goniometry, easier to use than other photographic-based goniometric assessments. Further studies are required to assess its reliability for the measurement of other joints.

1 September 2010 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
FFFranco Franchignoni
Franco Franchignoni
AGAndrea Giordano
Andrea Giordano
FSFrancesco Sartorio
Francesco Sartorio
SVStefano Vercelli
Stefano Vercelli
BPBarbara Pascariello
Barbara Pascariello
GFGiorgio Ferriero
Giorgio Ferriero

1 April 2011 in Manual Therapy
Verified
Journal Article
Closed access
FFFranco Franchignoni
Franco Franchignoni
GFGiorgio Ferriero
Giorgio Ferriero
AGAndrea Giordano
Andrea Giordano
FSFrancesco Sartorio
Francesco Sartorio
SVStefano Vercelli
Stefano Vercelli
EBElisa Brigatti
Elisa Brigatti

19 December 2011 in PM&R
Verified
Journal Article
Closed access
GFGiorgio Ferriero
Giorgio Ferriero
FSFrancesco Sartorio
Francesco Sartorio
CFCalogero Foti
Calogero Foti
DPDiego Primavera
Diego Primavera
EBElisa Brigatti
Elisa Brigatti
SVStefano Vercelli
Stefano Vercelli

1 January 2013 in Journal of Hand Therapy
Verified
Journal Article
Closed access
FSFrancesco Sartorio
Francesco Sartorio
EBElisabetta Bravini
Elisabetta Bravini
SVStefano Vercelli
Stefano Vercelli
GFGiorgio Ferriero
Giorgio Ferriero
GPGiuseppe Plebani
Giuseppe Plebani
FFFranco Franchignoni
Franco Franchignoni