F.J. Arregui

Dr. F.J. Arregui

Universitat Politècnica de València, Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2005 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
JAJavier Almandoz
Javier Almandoz
EMEnrique Cabrera Marcet
Enrique Cabrera Marcet
FAF.J. Arregui
F.J. Arregui
RCRicardo Cobacho
Ricardo Cobacho
Presented herein is a methodology for evaluation of water losses based on discrimination of the two components of uncontrolled water in a water distribution network: physical losses in mains and service connections, and the volume of water consumed but not measured by meters. The water balance calculations consider that all nonmeasured consumption is uncontrolled water and consequently an apparent loss. The methodology is applicable to an entire network or portions thereof, and presumes that real losses in certain physical states of a network are a function of pressure, while apparent losses (defined as nonmetered consumed water) are a function of consumption patterns (i.e., domestic, industrial, institutional, etc.). An extended period simulation of a water distribution network is employed to accurately determine both terms.

9 January 2018 in Water
Verified
Journal Article
Open access
PDF file
LJLaura Pastor Jabaloyes
Laura Pastor Jabaloyes
FAF.J. Arregui
F.J. Arregui
RCRicardo Cobacho
Ricardo Cobacho
Disaggregating residential water end use events through the available commercial tools needs a great investment in time to manually process smart metering data. Therefore, it is extremely difficult to achieve a homogenous and sufficiently large corpus of classified single-use events capable of accurately describe residential water consumption. The main goal of the present paper is to develop an automatic tool that facilitates the disaggregation of the individual water consumptions events from the raw flow trace. The proposed disaggregation methodology is conducted through two actions that are iteratively performed: first, the use of an advanced two-step filter, whose calibration is automatically conducted by the Elitist Non-Dominated Sorting Genetic Algorithm NSGA-II; and second, a cropping algorithm based on the filtered water consumption flow traces. As a secondary goal, yet complementary to the main one, a semiautomatic massive classification process has been developed, so that the resulting single-use events can be easily categorized in the different water end uses in a household. This methodology was tested using water consumption data from two different case studies. The characteristics of the households taken as reference and their occupants were unequivocally dissimilar from each other. In addition, the monitoring equipment used to obtain the consumption flow traces had completely different technical specifications. The results obtained from the processing of the two studies show that the automatic disaggregation is both robust and accurate, and produces significant time saving compared to the standard manual analysis.

1 December 2006 in Water Practice & Technology
Verified
Journal Article
Closed access
PDF file
FAF.J. Arregui
F.J. Arregui
ECE. Cabrera
E. Cabrera
RCR. Cobacho
R. Cobacho
JGJ. García-Serra
J. García-Serra
Apparent losses caused by meters inaccuracies can be reduced by analysing meters performance in the water supply and identifying the main causes of inaccuracies. These can have its origin on the meters design and accuracy curves, users’ consumption patterns, or specific characteristics of the water supply system.

1 April 2011 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
MCM. Carlos
M. Carlos
FAF.J. Arregui
F.J. Arregui
EMEnrique Cabrera Marcet
Enrique Cabrera Marcet
CPC. V. Palau
C. V. Palau
Water transients with entrapped air can originate large pressure peaks that can severely damage distribution networks. Entrapped air can have a damping or amplifying effect on these undesirable pressure peaks. Unfortunately, the complexity of the phenomenon too often makes it difficult to obtain a fully reliable prediction about when air pockets will mitigate or accentuate water transients. Furthermore, the value of some of the parameters involved in the conventional numerical models cannot be calculated or measured and need to be determined through a calibration process. With the aim of overcoming most of the aforementioned uncertainties, this paper summarizes a complete set of tests conducted at WL | Delft Hydraulics. These tests were simulated by means of a tailored numerical model that includes a set of parameters whose values were determined by means of a calibration process. The experimental setup, a large-scale facility, consisted of a single steep pipeline with an air valve installed at its top end. Air release through different air valves was tested under different conditions.

24 November 2022 in Water
Verified
Journal Article
Open access
PDF file
MAMusaad Alhudaithi
Musaad Alhudaithi
FAF.J. Arregui
F.J. Arregui
RCRicardo Cobacho
Ricardo Cobacho
This work proposes a novel indicator (HCWI) for evaluating water consumption efficiency in hotels. The indicator is built as a relative index that compares the current water consumption with an estimated minimum achievable value. To ensure the representativeness and applicability of the index, the evaluation of this water consumption baseline considers each water consumption micro-component individually and has been simplified, so it only requires fundamental characteristics of the hotel and those that are easy to identify and quantify. A value of the HCWI equal to one indicates the best water use efficiency that can be theoretically achieved with the technology available. On the contrary, larger values of the HWCI indicate high levels of water use inefficiency by the hotel. The applicability of the indicator is tested in six different hotels located in a touristic region in the north of Spain.

8 May 2018 in Water
Verified
Journal Article
Open access
PDF file
FAF.J. Arregui
F.J. Arregui
Francesc J. GavaraFrancesc J. Gavara
Francesc J. Gavara
JOJavier Soriano Olivares
Javier Soriano Olivares
LJLaura Pastor Jabaloyes
Laura Pastor Jabaloyes
Single-jet meters are one of the most frequently used domestic meters that can be found in water distribution systems. Like any other water meter technology, they have significant metrological limitations that prevent them, even if recently installed, from measuring all water consumption of a domestic customer. After installation, their metrological characteristics evolve depending on the particular design of the meters and their actual working conditions in the field. This work presents a comprehensive set of tests to determine the initial and after installation weighted error of two types of domestic single-jet water meters. Three non-linear degradation models have been derived from the tests results. These models consider age, totalised volume, or both parameters simultaneously as drivers of the weighted error. The results show that even though the construction of the two examined meters is similar, they have been working under comparable operational conditions and measuring water of the same quality, there is a significant difference in the performance between both types. This result highlights the need to conduct individual analyses for each meter type and the impossibility of generalizing conclusions on how the weighted error could evolve over time.