Francisco Mateo-Elgueda

Mr. Francisco Mateo-Elgueda

Architecture and Built Environment, University of Nottingham, Nottingham, UK
orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2026
Verified
Journal Article
Open access
PDF file
MWMeixin Wu
Meixin Wu
Francisco Mateo-ElguedaFrancisco Mateo-Elgueda
Francisco Mateo-Elgueda
Yuehong SuYuehong Su
Yuehong Su
Addressing the critical challenge of summer overheating in passive solar systems, this study evaluates the year-round thermal and energy performance of a seasonally shaded and fan-assisted Trombe wall in Beijing’s Hot-Summer - Cold-Winter (HSCW) climate. Using a simulation-based approach, four facade configurations were compared against a standard south-facing window baseline. Results demonstrate that while an unshaded Trombe wall (TW) reduces annual heating demand by 27%, it imposes a 25% cooling penalty. The permanent deployment of external blinds (TW+Blinds) from May to September effectively mitigates this impact, reducing the cooling load by 13% compared to the unshaded configuration and limiting the final summer penalty to only 8.7% above the baseline. The hybrid configuration, incorporating both seasonal shading and an auxiliary cavity fan (TW+Blinds+Fan), achieves the highest overall performance, delivering a 30.3% reduction in annual heating demand and a 14% net saving in total annual energy use. Furthermore, annual thermal habitability improves by 20.7% based on the frequency of occupied hours maintained within the 20 °C to 26 °C safety range. The analysis identifies seasonal shading as the primary driver for annual balance, while the performance decrease observed in April reveals that fixed-schedule fan assistance introduces operational trade-offs during transitional months.

21 July 2026 in Electronics
Verified
Journal Article
Open access
PDF file
Francisco Mateo-ElguedaFrancisco Mateo-Elgueda
Francisco Mateo-Elgueda
Marco RiveraMarco Rivera
Marco Rivera
Yuehong SuYuehong Su
Yuehong Su
MCMaría Luisa del Campo_Hitschfeld
María Luisa del Campo_Hitschfeld
Climate change compels the built environment to adopt adaptive Building-Integrated PhotoVoltaic (BIPV) designs balancing energy yields with indoor environmental quality. However, current dynamic facades suffer from algorithmic opacity and an operational bias prioritising generation over human comfort. This study systematically reviews the energy–comfort nexus within intelligent building skins. Following PRISMA 2020 guidelines, we searched nine databases (including Scopus and Web of Science) for empirical studies (2016–early 2026) evaluating dynamic BIPV control. Methodological quality and bias risk were assessed via a rigorous framework evaluating control transparency and simulation validity. From 2423 initial records, 92 high-quality studies were selected and structured into six adaptive BIPV design clusters (e.g., Double-Skin Facades, kinetic shading, semi-transparent glazing). The synthesis reveals a polarisation between thermo-mechanical integration and computational–geometric optimisation. An energy-centric bias persists. Power generation dominates over 92% of research, whereas glare evaluation remains below 20%. Additionally, nearly 60% of studies fail to explicitly define their control parameters. Current evidence limitations include a heavy reliance on idealised 1D simulations, a strong Northern Hemisphere geographical concentration, and a scarcity of robust data on dynamic bifacial systems. Bridging the gap between PV hardware and intelligent control, this study delivers a comprehensive theoretical framework and an actionable roadmap.

9 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
GSGianmarco Sciurti
Gianmarco Sciurti
Francisco Mateo-ElguedaFrancisco Mateo-Elgueda
Francisco Mateo-Elgueda
AMAlberto Muscio
Alberto Muscio
YSYuehong Su
Yuehong Su
Solar heating/radiative cooling (SHRC) collectors combine solar air heating during sunlight periods with radiative heat emission to the sky, thereby addressing the seasonal mismatch that limits mono-functional solar heaters and stand-alone radiative coolers. This paper develops a complete building-energy assessment workflow for an air-based SHRC system. First, a reduced-order transient collector model is validated against an experimental PT/PT-RC dataset, using outlet air temperature as the primary validation variable. The solver is embedded in EnergyPlus through a PythonPlugin user-defined component and coupled with a hybrid outdoor-air/recirculation control strategy. Annual simulations are performed for a typical 100 m2 Italian apartment representative of the 1990-2005 building stock in Bologna, Rome and Palermo, considering 0, 5, 10 and 15 panels. To avoid double-counting with the baseline EnergyPlus air-loop fan, the additional pressure drop of the SHRC circuit is evaluated in post-processing using a Darcy-Weisbach network model including common ducts, branches, manifolds and the panel duct. For a 10 mm panel duct and baseline pressure-drop assumptions, the 15-panel configuration reduces corrected annual HVAC electricity from 2688 to 2371 kWh in Bologna, from 2083 to 1810 kWh in Rome and from 1965 to 1672 kWh in Palermo. The corresponding savings are 11.8%, 13.1% and 14.9%, respectively. Results indicate that the SHRC contribution is balanced between winter preheating and summer/night-time cooling in Bologna, while it is dominated by cooling in Palermo. The analysis also shows that the 10 mm duct remains preferable to 20 and 30 mm ducts in Bologna after including pressure-drop penalties, because its thermal benefit exceeds the fan-electricity increase. Overall, the results demonstrate that air-based SHRC systems can provide meaningful HVAC electricity savings across different Mediterranean climates when thermal performance, control strategy and auxiliary fan penalties are considered jointly. The proposed modelling framework therefore provides a practical basis for assessing and optimizing SHRC integration in residential buildings.