Gagan Kalra

Dr. Gagan Kalra

Cole Eye Institute - Cleveland Clinic
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2020 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
AWAndrew M. Williams
Andrew M. Williams
Gagan KalraGagan Kalra
Gagan Kalra
PCPatrick W. Commiskey
Patrick W. Commiskey
EBEve M. R. Bowers
Eve M. R. Bowers
BRBrian R. Rudolph
Brian R. Rudolph
RFRoxana Fu
Roxana Fu
The coronavirus disease 2019 pandemic has led to widespread change as public health strategies for containment have emphasized social distancing and remaining at home. These policies have led to downscaled clinic volumes, cancellation of elective procedures, enhanced personal protective strategies in the clinic, and adoption of telemedicine encounters. We describe the evidence-based practical approach taken in our ophthalmology department to continue delivering eye care during the pandemic by rescheduling visits, enhancing clinic safety, and adopting virtual video encounters.

20 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Gagan KalraGagan Kalra
Gagan Kalra
HCHasan Cetin
Hasan Cetin
JWJon Whitney
Jon Whitney
SYSari Yordi
Sari Yordi
YCYavuz Cakir
Yavuz Cakir
Justis P. EhlersJustis P. Ehlers
Justis P. Ehlers
Background: The development and testing of a deep learning (DL)-based approach for detection and measurement of regions of Ellipsoid Zone (EZ) At-Risk to study progression in nonexudative age-related macular degeneration (AMD). Methods: Used in DL model training and testing were 341 subjects with nonexudative AMD with or without geographic atrophy (GA). An independent dataset of 120 subjects were used for testing model performance for prediction of GA progression. Accuracy, specificity, sensitivity, and intraclass correlation coefficient (ICC) for DL-based EZ At-Risk percentage area measurement was calculated. Random forest-based feature ranking of EZ At-Risk was compared to previously validated quantitative OCT-based biomarkers. Results: The model achieved a detection accuracy of 99% (sensitivity = 99%; specificity = 100%) for EZ At-Risk. Automatic EZ At-Risk measurement achieved an accuracy of 90% (sensitivity = 90%; specificity = 84%) and the ICC compared to ground truth was high (0.83). In the independent dataset, higher baseline mean EZ At-Risk correlated with higher progression to GA at year 5 (p < 0.001). EZ At-Risk was a top ranked feature in the random forest assessment for GA prediction. Conclusions: This report describes a novel high performance DL-based model for the detection and measurement of EZ At-Risk. This biomarker showed promising results in predicting progression in nonexudative AMD patients.

Verified
Journal Article
Open access
PDF file
SYSari Yordi
Sari Yordi
YCYavuz Cakir
Yavuz Cakir
Gagan KalraGagan Kalra
Gagan Kalra
HCHasan Cetin
Hasan Cetin
Ming HuMing Hu
Ming Hu
Justis P. EhlersJustis P. Ehlers
Justis P. Ehlers
In this longitudinal retrospective image analysis, conducted on patients diagnosed with dry age-related macular degeneration (AMD) and 5 years of follow-up imaging data, the study aimed to investigate the relationship between ellipsoid zone (EZ) integrity on spectral domain optical coherence tomography (SD-OCT) and visual acuity (VA). Using a machine learning-enabled feature extraction tool, quantitative EZ parameters were derived from SD-OCT images. The analysis revealed significant correlations between EZ integrity metrics and VA. Eyes with excellent VA (≥20/25 Snellen) exhibited higher EZ integrity, including less EZ attenuation, thicker ellipsoid zone-retinal pigment epithelium (EZ-RPE) thickness, and higher EZ intensity, in contrast to eyes with worse VA (≤20/40 Snellen). Additionally, eyes with geographic atrophy (GA) in the foveal region displayed compromised EZ integrity compared to those without GA. Notably, baseline EZ integrity metrics were predictive of future VA loss. These findings suggest that quantitative SD-OCT measurements of EZ integrity could potentially detect early changes in dry AMD and serve as valuable indicators for predicting future functional outcomes. Furthermore, these measurements hold promise for use in clinical trial screenings, offering insights into the progression of the disease and its impact on visual acuity. This study underscores the importance of EZ integrity assessment in understanding and managing dry AMD.

1 September 2021 in Survey of Ophthalmology
Verified
Journal Article
Closed access
MLMarco Lupidi
Marco Lupidi
AMAlessio Muzi
Alessio Muzi
GCGreta Castellucci
Greta Castellucci
Gagan KalraGagan Kalra
Gagan Kalra
FPFelice Cardillo Piccolino
Felice Cardillo Piccolino
CCCarlo Cagini
Carlo Cagini

13 June 2020 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
Gagan KalraGagan Kalra
Gagan Kalra
AWAndrew M. Williams
Andrew M. Williams
PCPatrick W. Commiskey
Patrick W. Commiskey
EBEve M. R. Bowers
Eve M. R. Bowers
TSTadhg Schempf
Tadhg Schempf
RFRoxana Fu
Roxana Fu
Introduction The coronavirus disease 2019 (COVID-19) pandemic has led to rapid adoption of teleophthalmology to deliver eyecare remotely. The purpose of our study was to assess the implementation and patient acceptability of video consultation for outpatient ophthalmic care at our institution. Methods We conducted a retrospective, cross-sectional analysis and patient survey of adult patients who completed a virtual video visit at our institution from 18 March 18 through to 27 April 2020. All video visit encounters were assessed for patient characteristics, diagnoses, management, and follow-up outcomes. Patients were surveyed for their feedback on acceptability and utility of their virtual video consultation. Results A total of 219 patients (mean age 55 years; range 21–89 years) completed 231 video visit encounters at our department over a 6-week period, of whom 118 were women (54%). About half of these encounters were acute visits (102 visits, 47%). The most common diagnosis of these visits was postoperative state (20 visits, 9% of the total), followed by conjunctivitis (16 visits, 7%), and keratitis (14 visits, 6%). The most common management decisions were medication prescription (102 visits, 46%) or reassurance (86 visits, 39%), while 17 video visit patients (8%) were escalated to an urgent, in-person evaluation. Ninety-two patients completed a follow-up survey (42% response rate), of whom 45 (49%) indicated that they might have delayed seeking care during this pandemic in the absence of a virtual video option. Seventy-two (78%) reported that they would consider participating in a video visit as an alternative to an office-based encounter in the future, and the overall video visit experience was rated highly, with a weighted mean Likert scale rating of 4.3 out of 5 (Cronbach’s α = 0.88). Conclusion Virtual video visits may be used to manage a range of ophthalmic complaints. Patients participating in this survey found such video visits acceptable and timesaving, and the majority would consider using video consultations for future eyecare encounters.

24 December 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
Gagan KalraGagan Kalra
Gagan Kalra
HCHasan Cetin
Hasan Cetin
JWJon Whitney
Jon Whitney
SYSari Yordi
Sari Yordi
YCYavuz Cakir
Yavuz Cakir
Justis P. EhlersJustis P. Ehlers
Justis P. Ehlers
The current study describes the development and assessment of innovative, machine learning (ML)-based approaches for automated detection and pixel-accurate measurements of regions with geographic atrophy (GA) in late-stage age-related macular degeneration (AMD) using optical coherence tomography systems. 900 OCT volumes, 100266 B-scans, and en face OCT images from 341 non-exudative AMD patients with or without GA were included in this study from both Cirrus (Zeiss) and Spectralis (Heidelberg) OCT systems. B-scan and en face level ground truth GA masks were created on OCT B-scan where the segmented ellipsoid zone (EZ) line, retinal pigment epithelium (RPE) line, and bruchs membrane (BM) line overlapped. Two deep learning-based approaches, B-scan level and en face level, were trained. The OCT B-scan model had detection accuracy of 91% and GA area measurement accuracy of 94%. The en face OCT model had detection accuracy of 82% and GA area measurement accuracy of 96% with primary target of hypertransmission on en face OCT. Accuracy was good for both devices tested (92–97%). Automated lesion size stratification for CAM cRORA definition of 250um minimum lesion size was feasible. High-performance models for automatic detection and segmentation of GA area were achieved using OCT systems and deep learning. The automatic measurements showed high correlation with the ground truth. The en face model excelled at identification of hypertransmission defects. The models performance generalized well across device types tested. Future development will include integration of both models to enhance feature detection across GA lesions as well as isolating hypertransmission defects without GA for pre-GA biomarker extraction.