Ganesh Thiagarajan

Dr. Ganesh Thiagarajan


Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
TGTrent M. Guess
Trent M. Guess
HLHongzeng Liu
Hongzeng Liu
SBSampath Bhashyam
Sampath Bhashyam
GTGanesh Thiagarajan
Ganesh Thiagarajan
Combining musculoskeletal simulations with anatomical joint models capable of predicting cartilage contact mechanics would provide a valuable tool for studying the relationships between muscle force and cartilage loading. As a step towards producing multibody musculoskeletal models that include representation of cartilage tissue mechanics, this research developed a subject-specific multibody knee model that represented the tibia plateau cartilage as discrete rigid bodies that interacted with the femur through deformable contacts. Parameters for the compliant contact law were derived using three methods: (1) simplified Hertzian contact theory, (2) simplified elastic foundation contact theory and (3) parameter optimisation from a finite element (FE) solution. The contact parameters and contact friction were evaluated during a simulated walk in a virtual dynamic knee simulator, and the resulting kinematics were compared with measured in vitro kinematics. The effects on predicted contact pressures and cartilage–bone interface shear forces during the simulated walk were also evaluated. The compliant contact stiffness parameters had a statistically significant effect on predicted contact pressures as well as all tibio-femoral motions except flexion–extension. The contact friction was not statistically significant to contact pressures, but was statistically significant to medial–lateral translation and all rotations except flexion–extension. The magnitude of kinematic differences between model formulations was relatively small, but contact pressure predictions were sensitive to model formulation. The developed multibody knee model was computationally efficient and had a computation time 283 times faster than a FE simulation using the same geometries and boundary conditions.

1 August 2020 in Bone
Verified
Journal Article
Closed access
GTGanesh Thiagarajan
Ganesh Thiagarajan
LLLoretta E. Laughrey
Loretta E. Laughrey
MNMohammadmehdi Niroobakhsh
Mohammadmehdi Niroobakhsh
NLNuria Lara-Castillo
Nuria Lara-Castillo

1 June 2020 in Bone Reports
Verified
Journal Article
Open access
HMHammad Mumtaz
Hammad Mumtaz
MDMark Dallas
Mark Dallas
MBMark Begonia
Mark Begonia
NLNuria Lara-Castillo
Nuria Lara-Castillo
JSJoAnna M. Scott
JoAnna M. Scott
GTGanesh Thiagarajan
Ganesh Thiagarajan
Aging is known to reduce bone quality and bone strength. We sought to determine how aging affects the biomechanical and architectural properties of various long bones, and if sex influences age related differences/changes. While researchers have extensively studied these changes in individual bones of mice, there is no comprehensive study of the changes in the bones from the same mice to study the changes with aging. We performed three point bending tests and microcomputed tomography (microCT) analysis on femurs, tibiae and ulnae. Three point bending tests were utilized to calculate biomechanical parameters and imaging was also performed using high resolution microCT to reveal both cortical and trabecular microarchitecture C57BL/6N mice were divided into three age groups: 6, 12 and 22 months. Each age and sex group consisted of 6-7 mice. The ultimate load to failure (UL), elastic stiffness (ES), modulus of elasticity (E) and the moment of inertia about bending axis (MOI) for each bone was calculated using three point bending test. MicroCT scans of all the bones were analyzed to determine cortical bone volume per tissue volume (C.BV/TV), trabecular bone volume per tissue volume (Tb.BV/TV), cortical bone area (B.Ar) using CTAn's microCT analysis and tested for correlation with the biomechanical parameters. Mean (standard error) values of UL in femur decreased from 19.8(0.6) N to 12.8(1.1) N (p < .01) and 17.9(0.6) N to 14.6(1.0) N (p = .02) from 6 to 22 months groups in males and females respectively. Similarly, UL in tibia decreased from 19.8(0.5) N to 14.3(0.2) N (p < .01) and 14.4(0.6) N to 9.5(1.0) N (p < .01) from 6 to 22 months group in males and females respectively. ES in femur decreased from 113.2(7) N/mm to 69.6(6.7) N/mm (p < .01) from 6 to 22 months in males only. ES in tibia decreased from 78.6(3.2) N/mm to 65.0(2.3) N/mm (p = .01) and 53.1(2.9) N/mm to 44.0(1.7) N/mm (p = .02) from 6 to 22 months in males and females respectively. Interestingly, ES in ulna increased from 8.2(0.8) N/mm to 10.9(1.0) N/mm (p = .051) from 6 to 22 months of age in females only. E in femur decreased from 4.0(0.4) GPa to 2.8(0.2) GPa (p = .01) and 6.7(0.5) GPa to 4.5(0.4) GPa (p = .01) from 6 to 22 months of age in males and females respectively while tibia showed no change. However, E in ulna increased from 7.0(0.8) GPa to 11.0(1.1) GPa (p = .01) from 6 to 22 months of age in females only. Changes in age and sex-related bone properties were more pronounced in the femur and tibia, while the ulna showed fewer overall differences. Most of the changes were observed in biomechanical compared to architectural properties and female bones are more severely affected by aging. In conclusion, our data demonstrate that care must be taken to describe bone site and sex-specific, rather than making broad generalizations when describing age-related changes on the biomechanical and architectural properties of the skeleton.

30 June 2004 in International Journal of Solids and Structures
Verified
Journal Article
Closed access
GTGanesh Thiagarajan
Ganesh Thiagarajan
Anil MisraAnil Misra
Anil Misra

7 September 2011 in Medical Engineering & Physics
Verified
Journal Article
Closed access
YLYunkai Lu
Yunkai Lu
GTGanesh Thiagarajan
Ganesh Thiagarajan
DNDaniel P. Nicolella
Daniel P. Nicolella
MJMark L. Johnson
Mark L. Johnson
Finite element analysis (FEA) of the mouse forearm compression loading model is used to relate strain distributions with downstream changes in bone formation and responses of bone cells. The objective of this study was to develop two FEA models - the first one with the traditional ulna only and the second one in which both the ulna and radius are included, in order to examine the effect of the inclusion of the radius on the strain distributions in the ulna. The entire mouse forearm was scanned using microCT and images were converted into FEA tetrahedral meshes using a suite of software programs. The performance of both linear and quadratic tetrahedral elements and coarse and fine meshes were studied. A load of 2N was applied to the ulna/radius model and a 1.3N load (based on previous investigations of load sharing between the ulna and radius in rats) was applied to the ulna only model for subsequent simulations. The results showed differences in the cross sectional strain distributions and magnitude within the ulna for the combined ulna/radius model versus the ulna only model. The maximal strain in the combined model occurred about 4mm toward the distal end from the ulna mid-shaft in both models. Results from the FEA model simulations were also compared to experimentally determined strain values. We conclude that inclusion of the radius in FE models to predict strains during in vivo forearm loading increases the magnitude of the estimated ulna strains compared to those predicted from a model of the ulna alone but the distribution was similar. This has important ramifications for future studies to understand strain thresholds needed to activate bone cell responses to mechanical loading.

1 December 2013 in International Journal of Protective Structures
Verified
Journal Article
Closed access
GTGanesh Thiagarajan
Ganesh Thiagarajan
RRRasekh Rahimzadeh
Rasekh Rahimzadeh
AKAritra Kundu
Aritra Kundu
The failure of reinforced concrete columns when subjected to blast events can be catastrophic to the building as a whole. The choice of the type of lateral confinement may influence the response of columns subjected to blast load much more when compared to the application of traditional loads. The objective of the research reported in this paper is to study the non-linear response of a typical reinforced concrete column with four types of lateral reinforcement subjected to uniform blast loading, using finite element (FE) and single degree of freedom (SDOF) methods. An advanced FE modeling tool, LS-DYNA and a widely used SDOF analysis tool – SBEDS – are used for this purpose. Pressure-Impulse (PI) diagrams for different levels of protection (LOP) are developed using both the methods. The mid height displacement is used to represent the levels of protection. A parametric analysis is used to develop PI diagrams in order to study the effect of confinement on the reduction of displacement at impulsive, dynamic, and quasi-static loading conditions. PI curves developed from the FE methods are compared with the curves from the SDOF methodology. Regression equations are also developed using statistical analysis, to characterize PI diagrams generated from the FE method. Recommendations for analysis, design and detailing of reinforced concrete columns for blast protection based on this research are presented.