Gary Garcia Molina

Dr. Gary Garcia Molina

Sleep Number Labs, San Francisco, California, USA
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2010 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
DZDanhua Zhu
Danhua Zhu
JBJordi Bieger
Jordi Bieger
GMGary Garcia Molina
Gary Garcia Molina
RARonald M. Aarts
Ronald M. Aarts
Brain-computer interface (BCI) systems based on the steady-state visual evoked potential (SSVEP) provide higher information throughput and require shorter training than BCI systems using other brain signals. To elicit an SSVEP, a repetitive visual stimulus (RVS) has to be presented to the user. The RVS can be rendered on a computer screen by alternating graphical patterns, or with external light sources able to emit modulated light. The properties of an RVS (e.g., frequency, color) depend on the rendering device and influence the SSVEP characteristics. This affects the BCI information throughput and the levels of user safety and comfort. Literature on SSVEP-based BCIs does not generally provide reasons for the selection of the used rendering devices or RVS properties. In this paper, we review the literature on SSVEP-based BCIs and comprehensively report on the different RVS choices in terms of rendering devices, properties, and their potential influence on BCI performance, user safety and comfort.

10 October 2018 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
GMGary Garcia Molina
Gary Garcia Molina
TTTsvetomira Kirova Tsoneva
Tsvetomira Kirova Tsoneva
JJJeff Jasko
Jeff Jasko
BSBrenda Steele
Brenda Steele
AAAntonio Aquino
Antonio Aquino
DWDavid P White
David P White
Recent evidence reports cognitive, metabolic, and sleep restoration benefits resulting from the enhancement of sleep slow-waves using auditory stimulation. Our objective is to make this concept practical for consumer use by developing and validating an electroencephalogram (EEG) closed-loop system to deliver auditory stimulation during sleep to enhance slow-waves. The system automatically detects slow-wave sleep with 74% sensitivity and 97% specificity and optimally delivers stimulation in the form of 50 ms-long tones separated by a constant one-second inter-tone interval at a volume that is dynamically modulated such that louder tones are delivered when sleep is deeper. The system was tested in a study involving 28 participants (18F, 10M; 36.9 ± 7.3 years old; median age: 40 years old) who used the system for ten nights (five nights in a sham condition and five in a stimulation condition). Four nights in each condition were recorded at-home and the fifth one in-lab. The analysis in two age groups defined by the median age of participants in the study shows significant slow wave activity enhancement (+16.1%, p < 0.01) for the younger group and absence of effect on the older group. However, the older group received only a fraction (57%) of the stimulation compared to the younger group. Changes in sleep architecture and EEG properties due to aging have influenced the amount of stimulation. The analysis of the stimulation timing suggests an entrainment-like phenomenon where slow-waves align to the stimulation periodicity. In addition, enhancement of spindle power in the stimulation condition was found. We show evidence of the viability of delivering auditory stimulation during sleep, at home, to enhance slow wave activity. The system ensures the stimulation delivery to be at the right time during sleep without causing disturbance.

25 March 2010 in IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans
Verified
Journal Article
Closed access
EKEmile J. C. Kelkboom
Emile J. C. Kelkboom
GMGary Garcia Molina
Gary Garcia Molina
JBJeroen Breebaart
Jeroen Breebaart
RVRaymond N. J. Veldhuis
Raymond N. J. Veldhuis
TKTom A. M. Kevenaar
Tom A. M. Kevenaar
WJWillem Jonker
Willem Jonker
In recent years, the protection of biometric data has gained increased interest from the scientific community. Methods such as the fuzzy commitment scheme, helper-data system, fuzzy extractors, fuzzy vault, and cancelable biometrics have been proposed for protecting biometric data. Most of these methods use cryptographic primitives or error-correcting codes (ECCs) and use a binary representation of the real-valued biometric data. Hence, the difference between two biometric samples is given by the Hamming distance (HD) or bit errors between the binary vectors obtained from the enrollment and verification phases, respectively. If the HD is smaller (larger) than the decision threshold, then the subject is accepted (rejected) as genuine. Because of the use of ECCs, this decision threshold is limited to the maximum error-correcting capacity of the code, consequently limiting the false rejection rate (FRR) and false acceptance rate tradeoff. A method to improve the FRR consists of using multiple biometric samples in either the enrollment or verification phase. The noise is suppressed, hence reducing the number of bit errors and decreasing the HD. In practice, the number of samples is empirically chosen without fully considering its fundamental impact. In this paper, we present a Gaussian analytical framework for estimating the performance of a binary biometric system given the number of samples being used in the enrollment and the verification phase. The error-detection tradeoff curve that combines the false acceptance and false rejection rates is estimated to assess the system performance. The analytic expressions are validated using the Face Recognition Grand Challenge v2 and Fingerprint Verification Competition 2000 biometric databases.

1 January 2010 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
GMGary Garcia Molina
Gary Garcia Molina
VMVojkan Mihajlovic
Vojkan Mihajlovic
Brain-computer interfaces (BCIs) based on steady-state visual evoked potentials (SSVEPs) require minimal user training and can offer higher information throughput compared to other BCI modalities. We focused on SSVEPs elicited by high-frequency stimuli (>30 Hz) because they cause minimal fatigue/annoyance and reduce the risk of inducing photoepileptic seizures. This paper presents an approach that analyzes electroencephalographic activity to automatically obtain the optimum spatial filter for detecting the SSVEP at a given stimulation frequency from a short signal where the stimulation is presented at intermittent periods interspersed with breaks. A vector space generated by sinusoidal signals at the stimulation frequency and harmonics is defined. The spatial filter coefficients result from maximizing the ratio between the energy of the spatially filtered signal and that of its orthogonal component with regard to the vector space. The spatial filters are customized for each BCI user through a short calibration procedure taking into account individual specificity. Our experiments on six subjects applying the spatial filters resulted in an average transfer rate ranging from 20.9 to 22.7 bits/min.

29 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FSFarzad Siyahjani
Farzad Siyahjani
GMGary Garcia Molina
Gary Garcia Molina
SBShawn Barr
Shawn Barr
FMFaisal Mushtaq
Faisal Mushtaq
The Sleep Number smart bed uses embedded ballistocardiography, together with network connectivity, signal processing, and machine learning, to detect heart rate (HR), breathing rate (BR), and sleep vs. wake states. This study evaluated the performance of the smart bed relative to polysomnography (PSG) in estimating epoch-by-epoch HR, BR, sleep vs. wake, mean overnight HR and BR, and summary sleep variables. Forty-five participants (aged 22–64 years; 55% women) slept one night on the smart bed with standard PSG. Smart bed data were compared to PSG by Bland–Altman analysis and Pearson correlation for epoch-by-epoch HR and epoch-by-epoch BR. Agreement in sleep vs. wake classification was quantified using Cohen’s kappa, ROC analysis, sensitivity, specificity, accuracy, and precision. Epoch-by-epoch HR and BR were highly correlated with PSG (HR: r = 0.81, |bias| = 0.23 beats/min; BR: r = 0.71, |bias| = 0.08 breaths/min), as were estimations of mean overnight HR and BR (HR: r = 0.94, |bias| = 0.15 beats/min; BR: r = 0.96, |bias| = 0.09 breaths/min). Calculated agreement for sleep vs. wake detection included kappa (prevalence and bias-adjusted) = 0.74 ± 0.11, AUC = 0.86, sensitivity = 0.94 ± 0.05, specificity = 0.48 ± 0.18, accuracy = 0.86 ± 0.11, and precision = 0.90 ± 0.06. For all-night summary variables, agreement was moderate to strong. Overall, the findings suggest that the Sleep Number smart bed may provide reliable metrics to unobtrusively characterize human sleep under real life-conditions.

25 January 2022 in Journal of Sleep Research
Verified
Journal Article
Closed access
PDF file
CDCharmaine Diep
Charmaine Diep
SFSuzanne Ftouni
Suzanne Ftouni
SDSean P. A. Drummond
Sean P. A. Drummond
GMGary Garcia Molina
Gary Garcia Molina
CAClare Anderson
Clare Anderson