Gilberto Martins Filho

Mr. Gilberto Martins Filho

Instituto Internacional de Neurociências Edmond e Lily Safra, Natal, Rio Grande do Norte, Brazil
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Gilberto Martins FilhoGilberto Martins Filho
Gilberto Martins Filho
CJCláudio Júnior
Cláudio Júnior
BSBruno Spinelli
Bruno Spinelli
IDIgor Damasceno
Igor Damasceno
FFFelipe Fiuza
Felipe Fiuza
EMEdgard Morya
Edgard Morya
One of the significant challenges today in the brain–machine interfaces that use invasive methods is the stability of the chronic record. In recent years, polymer-based electrodes have gained notoriety for achieving mechanical strength values close to that of brain tissue, promoting a lower immune response to the implant. In this work, we fabricated fully polymeric electrodes based on PEDOT:PSS for neural recording in Wistar rats. We characterized the electrical properties and both in vitro and in vivo functionality of the electrodes. Additionally, we employed histological processing and microscopical visualization to evaluate the tecidual immune response at 7, 14, and 21 days post-implant. Electrodes with 400-micrometer channels showed a 12 dB signal-to-noise ratio. Local field potentials were characterized under two conditions: anesthetized and free-moving. There was a proliferation of microglia at the tissue–electrode interface in the early days, though there was a decrease after 14 days. Astrocytes also migrated to the interface, but there was not continuous recruitment of these cells in the tissue; there was inflammatory stability by day 21. The signal was not affected by this inflammatory action, demonstrating that fully polymeric electrodes can be an alternative means to prolong the valuable time of neural recordings.

15 September 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
Gilberto Martins FilhoGilberto Martins Filho
Gilberto Martins Filho
CJCláudio José Mendes Júnior
Cláudio José Mendes Júnior
BSBruno Guedes Spinelli
Bruno Guedes Spinelli
IDIgor Zumba Damasceno
Igor Zumba Damasceno
FFFelipe Fiuza
Felipe Fiuza
EMEdgard Morya
Edgard Morya
One of the significant challenges today in the brain-machine interface using invasive methods is the stability of the chronic record. In recent years, polymer-based electrodes have gained notoriety for achieving mechanical strength values close to that of brain tissue, promoting a lower immune response to the implant. In this work, we fabricated fully polymeric electrodes based on PEDOT:PSS for neural recording in Wistar rats. We characterized the electrical properties and both in-vitro and in-vivo functionality of the electrodes. Also, we employed histological processing and microscopical visualization to evaluate tecidual immune response in 7, 14, and 21 days post-implant days. Electrodes with 400-micrometer channels showed a 12dB signal-to-noise ratio. Local field potentials were characterized under two conditions: anesthetized and free-moving. There was a proliferation of microglia to the tissue-electrode interface in the first days, with a decrease after 14 days. Astrocytes also migrated to the interface, but there was no continuous recruitment of these cells in the tissue, showing inflammatory stability at 21 days. The signal was not affected by this inflammatory action, demonstrating that fully polymeric electrodes can be an alternative to prolong the valuable time of neural recordings.

8 May 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
LCLeila Cavalcanti
Leila Cavalcanti
Gilberto Martins FilhoGilberto Martins Filho
Gilberto Martins Filho
RMRaquel Medeiros
Raquel Medeiros
HDHudson Diniz
Hudson Diniz
IDIgor Damasceno
Igor Damasceno
HSHougelle Simplicio
Hougelle Simplicio
Spinal cord electrical (SCS) stimulation alleviates motor deficits in rodent and primate models of Parkinson’s disease due to a suppression of synchronous corticostriatal low-frequency oscillation. Limited epidural space requires resistant biocompatible microelectrodes to deliver efficiently electrical currents through a metal–cellular interface. Platinum (Pt) microelectrodes may lead to material degradation and topography modification under prolonged electrical stimulation. Thus, microstimulation performance over time can deteriorate and affect the functional recovery produced by SCS. To investigate electrodes commonly implanted in the epidural space of rats, Pt microelectrodes immersed in physiological saline underwent 48 h of electrical stimulation (100 Hz; 1.0, 1.3, and 1.6 mA). A wettability test was performed to characterize the interaction of the contact angle before and after stimulation, and it was found that there was an increase in this angle after the stimulation. An electrical impedance test showed that electrochemical interactions caused an increase in impedance after the stimulation. A roughness analysis also showed an increase in roughness after stimulation. Pt electrodes under chronic electric stimulation are susceptible to degradation, and further studies can improve electrode stability and efficacy as new sensor technologies become available.