Giorgio Mackenzie Cruz Martínez

Dr. Giorgio Mackenzie Cruz Martínez

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Giorgio Mackenzie Cruz MartínezGiorgio Mackenzie Cruz Martínez
Giorgio Mackenzie Cruz Martínez
LUIS ADRIAN ZUNIGA AVILESLUIS ADRIAN ZUNIGA AVILES
LUIS ADRIAN ZUNIGA AVILES
This article presents a methodology for the design of rehabilitation devices that considers factors involved in a clinical environment. This methodology integrates different disciplines that work together. The methodology is composed by three phases and 13 stages with specific tasks, the first phase includes the clinical context considering the requirements of the patient and therapist during the rehabilitation, the second phase is focused in engineering based on the philosophy of digital twin, and in the third phase is evaluated the device. This article explains the characteristics of the methodology and how it was applied in the design of an exoskeleton for passive rehabilitation of upper limb.

5 February 2024
Verified
Book
Closed access
PDF file
LUIS ADRIAN ZUNIGA AVILESLUIS ADRIAN ZUNIGA AVILES
LUIS ADRIAN ZUNIGA AVILES
Giorgio Mackenzie Cruz MartínezGiorgio Mackenzie Cruz Martínez
Giorgio Mackenzie Cruz Martínez
Designing Exoskeletons focuses on developing exoskeletons, following the lifecycle of an exoskeleton from design to manufacture. It demonstrates how modern technologies can be used at every stage of the process, such as design methodologies, CAD/CAE/CAM software, rapid prototyping, test benches, materials, heat and surface treatments, and manufacturing processes. Several case studies are presented to provide detailed considerations on developing specific topics. Exoskeletons are designed to provide work-power, rehabilitation, and assistive training to sports and military applications. Beginning with a review of the history of exoskeletons from ancient to modern times, the book builds on this by mapping out recent innovations and state-of-the-art technologies that utilize advanced exoskeleton design. Presenting a comprehensive guide to computer design tools used by bioengineers, the book demonstrates the capabilities of modern software at all stages of the process, looking at computer-aided design, manufacturing, and engineering. It also details the materials used to create exoskeletons, notably steels, engineering polymers, composites, and emerging materials. Manufacturing processes, both conventional and unconventional are discussed—for example, casting, powder metallurgy, additive manufacturing, and heat and surface treatments. This book is essential reading for those in the field of exoskeletons, such as designers, workers in research and development, engineering and design students, and those interested in robotics applied to medical devices. <!----> <!----> <!----> <!---->

4 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJosé Luis Medina-Valdes
José Luis Medina-Valdes
LUIS ADRIAN ZUNIGA AVILESLUIS ADRIAN ZUNIGA AVILES
LUIS ADRIAN ZUNIGA AVILES
Giorgio Mackenzie Cruz MartínezGiorgio Mackenzie Cruz Martínez
Giorgio Mackenzie Cruz Martínez
GVGonzález Vilchis
González Vilchis
USUsiel Sandino Silva-Rivera
Usiel Sandino Silva-Rivera
Many exoskeletons in scientific communications and patents only reach a technology readiness level corresponding to an experimental physical model (EPM) or a low-fidelity prototype. While only operational in a laboratory environment, the increasing technology readiness level (TRL) in exoskeletons is not widely studied. This work presents a study to reach this aim based on a new methodology that includes two phases, eleven steps, and four case studies from EPM (TRL3) of ERMIS up to TRL 5 of ERMIS. The results of this article show the increase in TRL based on the analysis of the operational parameters of the ERMIS exoskeleton. The validation of the passive rehabilitation movements was made by characterizing the points of their trajectories assisted by an anthropomorphic mechanism used to measure the end-effector position of ERMIS by means of the acquisition of data, obtaining an error of 20 mm. In conclusion, the real performance parameters are detailed, explaining their causes according to the behavior of the exoskeleton in a real environment operating the four case studies. It presents the group of parameters that reach the TRL 5, which were validated in Computer-Aided Design (CAD) software.

5 February 2024
Verified
Book Chapter
Closed access
LUIS ADRIAN ZUNIGA AVILESLUIS ADRIAN ZUNIGA AVILES
LUIS ADRIAN ZUNIGA AVILES
Giorgio Mackenzie Cruz MartínezGiorgio Mackenzie Cruz Martínez
Giorgio Mackenzie Cruz Martínez
While CAD handles the design of a workpiece and CAE performs analysis tasks, CAM focuses on how to manufacture the workpiece. CAM prepares a CAD model for machining, checking for any geometry errors, creating a machining path, setting machine parameters, and setting up nesting to maximize machining efficiency. These are CAD-CAM-CAE software tools that are fundamental during the design cycle, helping to reach the nine levels of technological maturity (TRL), the nine levels of maturity for manufacturing (MRL), and the nine levels of maturity for investment (IRL). This chapter addresses the considerations for generating a work plan that allows reaching a certain level of technological maturity, as well as evaluating whether the prototype of an exoskeleton meets a certain level of technological maturity. In this context, the gathering of user requirements, the generation of the design concept, the operating principle, the experimental physical model, the prototypes for laboratory evaluation, prototypes for demonstration, the released products, certified products, and products in production are essential in terms of commercial exploitation. <!----> <!----> <!----> <!---->

3 July 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
CRChristian Romero-Martínez
Christian Romero-Martínez
LUIS ADRIAN ZUNIGA AVILESLUIS ADRIAN ZUNIGA AVILES
LUIS ADRIAN ZUNIGA AVILES
Giorgio Mackenzie Cruz MartínezGiorgio Mackenzie Cruz Martínez
Giorgio Mackenzie Cruz Martínez
JRJosé Javier Reyes-Lagos
José Javier Reyes-Lagos
JZJoel Zagoya
Joel Zagoya
ÁBÁngel Eduardo Bárcenas-García
Ángel Eduardo Bárcenas-García
Medical simulators have revolutionized clinical training, particularly in teaching skills such as cardiac auscultation. This review synthesizes recent advances in the technological design and implementation of cardiac simulators for medical education, alongside scientometric and patentometric analyses. The focus is on innovations enhancing efficacy, safety, and accessibility. Analyses included 69 patents published over the past five years, sourced from Google Patents, Patentscope, Espacenet, and The Lens. A bibliometric analysis was performed using 52 scientific reports from PubMed, ScienceDirect, and The Lens within the same timeframe. Key findings indicate an 8% increase in AI-integrated cardiac auscultation devices compared to conventional equipment. Furthermore, 85% of the studies reported compliance with applicable regulations of at least 90%, reflecting improved regulatory alignment. This analysis provides a foundation for future research and the development of more accurate and accessible educational tools for cardiac auscultation training.

5 February 2024
Verified
Book Chapter
Closed access
LUIS ADRIAN ZUNIGA AVILESLUIS ADRIAN ZUNIGA AVILES
LUIS ADRIAN ZUNIGA AVILES
Giorgio Mackenzie Cruz MartínezGiorgio Mackenzie Cruz Martínez
Giorgio Mackenzie Cruz Martínez
Various classifications can be found in the literature; many of these classifications take action systems, applications, and types of therapy as a reference to achieve medical rehabilitation, among other goals; however, types of exoskeletons need to be classified as technology evolves. Therefore, this chapter establishes a classification that includes exoskeletons with the technology of the last generation implemented until 2023. This classification takes as a reference point patent, scientific communications, commercial products, and International Federation of Robotics guidelines. Said classification includes a general classification divided into eight subclassifications, including exoskeletons for military, industrial, and service applications. <!----> <!----> <!----> <!---->