Giovana Gonçalves Da Silva

Ms. Giovana Gonçalves Da Silva

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2024 in Applied System Innovation
Verified
Journal Article
Open access
PDF file
Giovana Gonçalves Da SilvaGiovana Gonçalves Da Silva
Giovana Gonçalves Da Silva
AQAlexandre de Queiroz
Alexandre de Queiroz
EGEnio Garbelini
Enio Garbelini
WSWesley Prado Leão dos Santos
Wesley Prado Leão dos Santos
CMCarlos Roberto Minussi
Carlos Roberto Minussi
Alfredo Bonini NetoAlfredo Bonini Neto
Alfredo Bonini Neto
Total real and reactive power losses in electrical power systems are an inevitable phenomenon and occur due to several factors, such as conductor resistance, transformer impedance, line reactance, equipment losses, and phase unbalance. Minimizing them is crucial to the system’s efficiency. In this study, an artificial neural network, specifically a Multi-layer Perceptron, was employed to predict total real and reactive power losses in electrical systems. The network is composed of three layers: an input layer consisting of the variables loading factor, real and reactive power generated on the slack bus, a hidden layer, and an output layer representing the total real and reactive power losses. The training method used was backpropagation, adjusting the weights based on the desired output. The results obtained, using datasets from IEEE systems with 14, 30, and 57 buses, showed satisfactory performance, with a mean squared error of around 10−4 and a coefficient of determination (R2) of 0.998. In validation with 20% of the data that was not part of the training, the network demonstrated effectiveness, with a mean squared error around 10−3. This indicates that the network was able to accurately predict total power losses based on loads, generating estimates close to the desired values.

1 January 2025 in Technologies
Verified
Journal Article
Open access
PDF file
Alfredo Bonini NetoAlfredo Bonini Neto
Alfredo Bonini Neto
AQAlexandre de Queiroz
Alexandre de Queiroz
Giovana Gonçalves Da SilvaGiovana Gonçalves Da Silva
Giovana Gonçalves Da Silva
AGAndre Gifalli
Andre Gifalli
ASAndré Nunes de Souza
André Nunes de Souza
EGEnio Garbelini
Enio Garbelini
Technical power losses in power systems are unavoidable, caused by factors such as transformer impedance, conductor resistance, equipment inefficiencies, line reactance, and phase imbalances. Reducing these losses is essential for improving system efficiency. This study introduces an innovative approach using Artificial Neural Networks (ANN) combined with the graphical interface to predict complete curves of real and reactive power losses in power systems under various contingencies. The key advantage of this methodology is its speed, allowing quick estimation of power loss curves both in normal and contingency conditions, whether mild or severe. ANN models excel at capturing the nonlinear behavior of power systems, eliminating the need for iterative methods commonly used in traditional approaches. The results showed that the ANN performed effectively, with a mean squared error during training below the specified threshold. For samples not included in the training set, the network accurately estimated 99% of the real and reactive power losses within the specified range, with residuals around 10−3 and an overall accuracy rate of 99% between the desired and obtained outputs. Additionally, a Graphical User Interface (GUI) was implemented to facilitate user interaction, allowing for easy visualization of power-loss predictions and real-time adjustments.

Verified
Journal Article
Open access
PDF file
Giovana Gonçalves Da SilvaGiovana Gonçalves Da Silva
Giovana Gonçalves Da Silva
Ronald Felipe Marca RoqueRonald Felipe Marca Roque
Ronald Felipe Marca Roque
MSMoisés Arreguín Sámano
Moisés Arreguín Sámano
NDNeylan Leal Dias
Neylan Leal Dias
Ana Claudia de Jesus GolzioAna Claudia de Jesus Golzio
Ana Claudia de Jesus Golzio
Alfredo Bonini NetoAlfredo Bonini Neto
Alfredo Bonini Neto
This paper presents an Artificial Neural Network (ANN) approach for estimating total real and reactive power losses in electrical power systems. Three network architectures were explored: the Multilayer Perceptron (MLP), the Radial Basis Function (RBF) network, and the Generalized Regression Neural Network (GRNN). The main advantage of the proposed methodology lies in its ability to rapidly compute power loss values throughout the system. ANN models are especially effective due to their capacity to capture the nonlinear characteristics of power systems, thus eliminating the need for iterative procedures. The applicability and effectiveness of the approach were evaluated using the IEEE 14-bus test system and compared with the continuation power flow method, which estimates losses using conventional numerical techniques. The results indicate that the ANN-based models performed well, achieving mean squared error (MSE) values below the predefined threshold during both training and validation (0.001). Notably, the networks accurately estimated the total power losses within the expected range, with residuals on the order of 10−4. Among the models tested, the RBF network showed slightly superior performance in terms of error metrics, requiring fewer centers to meet the established criteria compared to the MLP and GRNN models (11 centers). However, the GRNN achieved the shortest processing time; even so, all three networks produced satisfactory and consistent results, particularly in identifying the critical points of electrical power systems, which is of fundamental importance for ensuring system stability and operational reliability.