Gipyo Kweon

Mr. Gipyo Kweon

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2025 in The Transactions of The Korean Institute of Electrical Engineers
Verified
Journal Article
Closed access
Gipyo KweonGipyo Kweon
Gipyo Kweon
JCJunsang Cha
Junsang Cha
SKSeokjun Kang
Seokjun Kang
YYYeontae Yoo
Yeontae Yoo
SJSeungmin Jeong
Seungmin Jeong
GJGilsoo Jang
Gilsoo Jang
Low-detectability events such as open-phase conditions (OPCs) and low-current arcs (LCAs) in the onsite power system of nuclear power plants are difficult to detect using conventional protection schemes because the resulting voltage and current distortions are often minimal and transient. These events can persist undetected for long durations, leading to asymmetric loading, winding overheating, and increased risk of cascading equipment failures. This paper proposes a real-time two-stage convolutional neural network (CNN) framework that enables reliable detection of such events using only three-phase voltage and current measurements from a single load bus. In the first stage, a one-dimensional CNN (1D-CNN) monitors power quality disturbances (PQDs) within 5-cycle sliding windows, while a parallel reliability check mechanism periodically generates checkpoints to avoid missed detections. In the second stage, waveform segments corresponding to PQDs or checkpoints are transformed into time-frequency representations using signal-processing techniques such as the discrete wavelet transform (DWT) and empirical mode decomposition (EMD) from the Hilbert-Huang transform (HHT). These processed features are then classified using a two-dimensional CNN (2D-CNN). The proposed framework was validated through PSCAD/EMTDC simulations incorporating normal, OPC, and LCA conditions. The results demonstrate that the framework can accurately distinguish normal and abnormal events, with robust performance even under weak signal conditions. By combining data-driven PQD detection and selective event classification, the proposed method significantly reduces computational burden while maintaining real-time applicability, providing a practical and scalable diagnostic tool for onsite power systems of the nuclear power plant.

30 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
Gipyo KweonGipyo Kweon
Gipyo Kweon
MKMinseok Kim
Minseok Kim
DLDaebeom Lee
Daebeom Lee
CKChaea Kim
Chaea Kim
DLDongwon Lee
Dongwon Lee
JPJeonghoo Park
Jeonghoo Park
The large-scale integration of renewable energy into modern power grids has led to a critical reduction in both system-wide rotational inertia and localized system strength. While previous studies have often analyzed these two factors in isolation, this paper observes their interdependent relationship. Specifically, this paper demonstrates the impact of short-circuit capacity (SCC) on system reserve requirements by quantifying the Frequency Regulating Reserve (FRR) volume necessary to satisfy frequency nadir criteria under the most severe contingency. This quantification is based on a comparative analysis of regional renewable energy deployment in the Korean power system. The simulation results reveal that the required FRR increases significantly when renewables are deployed in areas with low SCC. These findings highlight the potential hidden costs of interconnecting renewables in a weak grid area, particularly from the perspective of system inertia, underscoring the necessity of considering location-aware markets in future power systems.