Giuseppe Brunetti

Dr. Giuseppe Brunetti

Polytechnic University of Bari, Bari, Puglia, Italy
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2023 in IEEE Photonics Technology Letters
Verified
Journal Article
Open access
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
RHR. Heuvink
R. Heuvink
ESE. Schreuder
E. Schreuder
MAMario Nicola Armenise
Mario Nicola Armenise
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli

29 March 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
Francesco Dell'olioFrancesco Dell'olio
Francesco Dell'olio
DCDonato Conteduca
Donato Conteduca
MAMario Nicola Armenise
Mario Nicola Armenise
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli

12 February 2020 in Journal of Optics
Verified
Journal Article
Closed access
PDF file
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
Francesco Dell'olioFrancesco Dell'olio
Francesco Dell'olio
DCDonato Conteduca
Donato Conteduca
MAMario Nicola Armenise
Mario Nicola Armenise
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli
A comprehensive electromagnetic mathematical model of an ultra-high Q -factor 1D-PhC ring resonator (1D-PhCRR) is proposed. The 1D-PhCRR results by the integration of a 1D-PhC in a ring cavity and its operation is based on the slow-light effect, allowing an improvement of the Q -factor of at least three orders of magnitude in comparison with the values obtained for a ring resonator without the grating. Accurate modelling and simulation of such ultra-high- Q ring resonator require very long simulation time and huge computing resource by using the conventional numerical methods, as the finite element method and finite difference time domain, because of the structure complexity. Therefore, to overcome these bottlenecks, an accurate mathematical model has been developed, able to take into account the waveguide curvature and dispersion, and the effect of the grating in the coupling region, reducing also the computation time. An ultra-high Q -factor (>10 9 ) 1D-PhCRR in Si 3 N 4 technology with a footprint of 16 mm 2 has been simulated in relatively short computer time, using the model described in the paper. This performance makes the 1D-PhCRR suitable for several applications, such as filters, ultra-sensitive biosensors and integrated photonic-gyroscopes, for which ultra-high Q -factor sensitive element ensures a high resolution.

13 February 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
DCDonato Conteduca
Donato Conteduca
Francesco Dell'olioFrancesco Dell'olio
Francesco Dell'olio
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli
MAMario N. Armenise
Mario N. Armenise
The design of a continuously tunable optical delay line based on a compact graphene-based silicon Bragg grating is reported. High performance, in terms of electro-optical switching time (tswitch < 8 ns), delay range (Δτ = 200 ps), and figure of merit FOM = Δτ/A = 1.54x105 ps/mm2, has been achieved with an ultra-compact device footprint (A ~1.3 x 10−3 mm2), so improving the state-of-the-art of integrated optical delay lines. A continuous and complete tunability of the delay time can be achieved with a very low delay loss ( = 0.03 dB/ps) and a weak power consumption ( = 0.05 mW/ps). A flat bandwidth B = 1.19 GHz has been calculated by exploiting the slow-light effect in the device. This performance makes the proposed optical delay line suitable for several applications in Microwave Photonics (MWP), such as beamsteering/beamforming, for which large delay range, flat and wide bandwidth and small volume are required.

12 January 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
ATAnnarita di Toma
Annarita di Toma
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
PCPaola Colapietro
Paola Colapietro
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli
In the last ten years, advances in diagnosis and treatment have played a significant role in counteracting the growth of dangerous diseases. Recently, several studies have demonstrated that monitoring proteins in the human body helps predictive monitoring of human health conditions and disease progress. In this context, bio-recognition techniques with high resolution are crucial. Evanescent-field biosensors have been widely investigated and successfully developed thanks to their ultra-high sensitivity. However, their resolution is mitigated by the nature of the Lorentzian spectral lineshape that shows inevitable significant spectral overlap among similar concentration-related resonances. To overcome this problem, a novel ultra-compact photonic biosensor with a tailored resonance shape is proposed. The device consists of 1D Photonic Crystal with engineered defects to achieve resonance with a box-like shape, a very large roll-off (= -10.50 dB/oct.), within a small footprint (≈ 1 ∙ 10 -2 μm 2 ), enabling single wavelength interrogation. The strong biosensor-analyte interaction is associated with a larger transmission change with respect to biosensors with Lorentzian shape (> 4 dB vs. > 0.5 dB for proteins Immunoglobulin-G (IgG) concentration from 1 pg/mL to 500 pg/mL), drastically decreasing the read errors.

19 June 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
DCDonato Conteduca
Donato Conteduca
Giuseppe BrunettiGiuseppe Brunetti
Giuseppe Brunetti
Francesco Dell'olioFrancesco Dell'olio
Francesco Dell'olio
MAMario N. Armenise
Mario N. Armenise
TKThomas F. Krauss
Thomas F. Krauss
Caterina CiminelliCaterina Ciminelli
Caterina Ciminelli
Antimicrobial resistance (AMR) describes the ability of bacteria to become immune to antimicrobial treatments. Current testing for AMR is based on culturing methods that are very slow because they assess the average response of billions of bacteria. In principle, if tests were available that could assess the response of individual bacteria, they could be much faster. Here, we propose an electro-photonic approach for the analysis and the monitoring of susceptibility at the single-bacterium level. Our method employs optical tweezers based on photonic crystal cavities for the trapping of individual bacteria. While the bacteria are trapped, antibiotics can be added to the medium and the corresponding changes in the optical properties and motility of the bacteria be monitored via changes of the resonance wavelength and transmission. Furthermore, the proposed assay is able to monitor the impedance of the medium surrounding the bacterium, which allows us to record changes in metabolic rate in response to the antibiotic challenge. For example, our simulations predict a variation in measurable electrical current of up to 40% between dead and live bacteria. The proposed platform is the first, to our knowledge, that allows the parallel study of both the optical and the electrical response of individual bacteria to antibiotic challenge. Our platform opens up new lines of enquiry for monitoring the response of bacteria and it could lead the way towards the dissemination of a new generation of antibiogram study, which is relevant for the development of a point-of-care AMR diagnostics.