Gorka Solana Arteche

Dr. Gorka Solana Arteche

Faculdade de Engenharias e Tecnologias, Universidade Save, Maxixe, Inhambane, Mozambique
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
RFRamon Farre
Ramon Farre
GTGerard Trias
Gerard Trias
GAGorka Solana Arteche
Gorka Solana Arteche
GGGemma Ginovart
Gemma Ginovart
DGDavid Gozal
David Gozal
DNDaniel Navajas
Daniel Navajas

6 February 2019 in European Respiratory Journal
Verified
Journal Article
Closed access
PDF file
RFRamon Farre
Ramon Farre
JMJosep M. Montserrat
Josep M. Montserrat
GAGorka Solana Arteche
Gorka Solana Arteche
DGDavid Gozal
David Gozal
DNDaniel Navajas
Daniel Navajas

15 September 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RFRamon Farre
Ramon Farre
MRMiguel A. Rodríguez-Lázaro
Miguel A. Rodríguez-Lázaro
Juliá GonzalezJuliá Gonzalez
Juliá Gonzalez
PCPedro Castro-Rebollo
Pedro Castro-Rebollo
THTeresa Hospital
Teresa Hospital
JOJorge Otero
Jorge Otero
Background: Negative (vacuum) pressure therapy promotes wound healing. However, commercially available devices are unaffordable to most potential users in low- and middle-income countries (LMICs), limiting access to many patients who could benefit from this treatment. This study aimed to design and test a cheap and easy-to-build negative pressure device and provide its detailed open-source description, thereby enabling free replication. Methods: the negative pressure device was built using off-the-shelf materials available via e-commerce and was based on a small pump, a pressure transducer, and the simplest Arduino controller with a digital display (total retail cost ≤ 75 US$). The device allows the user to set any therapeutic range of intermittent negative pressure and has two independent safety mechanisms. The performance of the low-cost device was carefully tested on the bench using a phantom wound, producing a realistic exudate flow rate. Results: the device generates the pressure patterns set by the user (25–175 mmHg of vacuum pressure, 0–60 min periods) and can drain exudate flows within the clinical range (up to 1 L/h). Conclusions: a novel, low-cost, easy-to-build negative pressure device for wound healing displays excellent technical performance. The open-source hardware description provided here, which allows for free replication and use in LMICs, will facilitate the application and wider utilization of this therapy to patients.

17 July 2023 in HardwareX
Verified
Journal Article
Open access
RCRubén Cuervo
Rubén Cuervo
MRMiguel A. Rodríguez-Lázaro
Miguel A. Rodríguez-Lázaro
RFRamon Farré
Ramon Farré
DGDavid Gozal
David Gozal
GAGorka Solana Arteche
Gorka Solana Arteche
JOJorge Otero
Jorge Otero
An unacceptably large number of newborn infants die in developing countries. For a considerable number of cases (particularly in preterm infants), morbidity and mortality can be reduced by simply maintaining newborn thermal homeostasis during the first weeks of life. Unfortunately, deaths caused by prematurity remain inordinately common in low- and middle-income countries (LMICs) due to reduced access to incubators in light of the high cost of commercially available devices. We herein describe and test a low-cost and easy-to-assemble neonatal incubator created with inexpensive materials readily available in LMICs. The incubator is based on an Arduino microcontroller. It maintains controlled temperature and relative humidity inside the main chamber while continuously measuring newborn weight progress. Moreover, the incubator has a tilting bed system and an additional independent safety temperature alarm. The performance of the novel low-cost neonatal incubator was evaluated and successfully passed the IEC 60601-2-19 standards. In the present work, we provide all the necessary technical information, which is distributed as open source. This will enable assembly of very low-cost (<250 €) and fully functional incubators in LMICs that should help reduce neonatal mortality.

1 May 2020 in Journal of Coastal Research
Verified
Journal Article
Closed access
PDF file
GAGorka Solana Arteche
Gorka Solana Arteche
Manel GrifolManel Grifol
Manel Grifol
MEManuel Espino
Manuel Espino
Solana, G.; Grifoll, M., and Espino, M, 2020. Hydrographic variability and estuarine classification of Inhambane Bay (Mozambique). In: Malvárez, G. and Navas, F. (eds.), Global Coastal Issues of 2020. Journal of Coastal Research, Special Issue No. 95, pp. 649–653. Coconut Creek (Florida), ISSN 0749-0208.This study investigates the hydrographic variability and the estuarine classification obtained from a set of field campaign data in Inhambane Bay (Mozambique). In situ measured salinity, temperature and sea-level data, together with Sea Surface Temperature (SST) obtained from GHRSST project, enabled to investigate the seasonal and inter-annual variability of the hydrography of the bay. Inhambane Bay is a bifurcated two-channel bar-built estuary with an along-coast channel of 30.5 km and a secondary channel of 12.5 km. In terms of tidal classification, Inhambane Bay is classified into the meso-tidal category forced by semi-diurnal tides with a Form Number equal to 0.04. The maximum observed tidal range is ∼3.41 m, with mean spring and neap tidal ranges of ∼2.61 m and ∼1.34 m, respectively. Also, the mean salinity profiles are practically uniform (well-mixed estuary) due to the strong tidal forcing being the Richardson Estuarine number below 0.08. The flushing time is estimated between 1 and 3 days. The characterization presented in this research is novel in the region and involves for the first time systematic in situ observations. The conclusions may be useful for similar unexplored areas along the Mozambican coast.

8 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
JOJorge Otero
Jorge Otero
MRMiguel A. Rodriguez-Lazaro
Miguel A. Rodriguez-Lazaro
RSRaffaella Salama
Raffaella Salama
DMDaniel Mbanze
Daniel Mbanze
GAGorka Solana Arteche
Gorka Solana Arteche
RFRamon Farre
Ramon Farre
Very prevalent respiratory and cardiovascular diseases result in chronic hypoxia, promoting metabolic, kidney, heart, and other malignant diseases. Hypoxia research employs animal models based on chronically breathing hypoxic air (O2<21%), usually by injecting N2 into the animal’s chamber. However, continuous high-flow N2 supply is available only in limited facilities, reducing the capability of widely conducting hypoxia research. Here, we describe an optimized setting for subjecting rodents to chronic normobaric hypoxia by requiring minimal N2 supply. The setting is based on providing the O2 consumed by the animals and eliminating the exhaled CO2 and water vapor. O2, CO2, temperature, and humidity in the hypoxic chamber are controlled by an Arduino-based unit activating a pump that introduces room air to restore the metabolized O2. Another pump continuously recirculates the chamber air through a Peltier-based dryer and CO2-absorbing soda lime. To correct any deviation in the actual value of hypoxia within the chamber, the control unit allows the injection of N2 into the chamber from a gas source. The setting performance was successfully tested in vivo when subjecting mice to 11%-O2 chronic hypoxia. This device, requiring a low N2 supply, may facilitate in vivo experimental research of hypoxiarelated diseases.