Gülşah Yıldırım

Prof. Dr. Gülşah Yıldırım


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Northern Clinics of Istanbul
Verified
Journal Article
Open access
HKHakki Karakas
Hakki Karakas
GYGülşah Yıldırım
Gülşah Yıldırım
MFMehmet Mahir Fersahoglu
Mehmet Mahir Fersahoglu
OFOzge Findik
Ozge Findik
Cholecystectomy is the standard treatment of acute cholecystitis. Surgery, however, poses significant risks for patients with advanced age and/or comorbid conditions. For such patients, percutaneous cholecystostomy (PC) is the only option. This interventional procedure does not have any absolute contraindications because of the life-threatening nature of the disease, in which other treatment options cannot be offered due to their risks. Nonetheless, these risk factors necessitate performing PC under urgent, rapid, and in many cases suboptimal conditions. In this article, PC was revisited in the light of our extensive experience in addition to the most current literature. Pre-procedural evaluation including the risk assessment and procedural steps was presented in detail. If conducted properly, PC provides significant clinical improvement in the short term and is life-saving, especially in the elderly and in patients with comorbid diseases or high surgical risk. It may also be the definitive treatment method for acute cholecystitis.

20 September 2021 in Diagnostic and Interventional Radiology
Verified
Journal Article
Closed access
HKHakki Muammer Karakas
Hakki Muammer Karakas
GYGülşah Yıldırım
Gülşah Yıldırım
EÇEsin Derin Çiçek
Esin Derin Çiçek
PURPOSE The widespread use of computed tomography (CT) in COVID-19 may cause adverse biological effects. Many recommend to minimize radiation dose while maintaining diagnostic quality. This study was designed to evaluate the difference between findings of COVID-19 pneumonia on standard and low-dose protocols to provide data on the utility of the latter during initial imaging of COVID-19. METHODS Patients suspected of having COVID-19 were scanned with a 128-slices scanner using two consecutive protocols in the same session (standard-dose scan: 120 kV and 300 mA; low-dose scan: 80 kV and 40 mA). Dose data acquisition and analysis was performed using an automated software. High and low-dose examinations were anonymized, shuffled and read by two radiologist with consensus according to a highly structured reporting format that was primarily based on the consensus statement of the RSNA. Accordingly, 8 typical, 2 indeterminate, and 7 atypical findings were investigated. Cases were then assigned to one of the categories: (i) Cov19Typ, typical COVID-19; (ii) Cov19Ind, indeterminate COVID-19; (iii) Cov19Aty, atypical COVID-19; (iv) Cov19Neg, not COVID-19. McNemar test was used to analyze the number of disagreements between standard and low-dose scans regarding paired proportions of structured findings. Intertest reliability was tested using kappa coefficient. RESULTS The study included 740 patients with a mean age of 44.05 +/- 16.59 years. The median (minimumm-aximum) dose level for standard protocol was 189.98 mGy.cm (98.20-493.54 mGy.cm) and for low-dose protocol was 15.59 mGy.cm (11.59-32.37 mGy.cm) differing by -80 and -254 mGy.cm from pan-European diagnostic reference levels. Only two findings for typical, one finding for indeterminate, and three findings for atypical categories were statistically similar (p > 0.05). The difference in other categories resulted in significantly different final diagnosis for COVID-19 (p < 0.001). Overall, 626 patients received matching diagnoses with the two protocols. According to intertest reliability analysis, kappa value was found to be 0.669 (p < 0.001) to indicate substantial match. CT with standard-dose had a sensitivity of 94% and a specificity of 72%, while CT with low-dose had a sensitivity of 90% and a specificity of 81%. CONCLUSION Low kV and mA scans, as used in this study according to scanner manufacturer's global recommendations, may significantly lower exposure levels. However, these scans are significantly inferior in the detection of several individual CT findings of COVID-19 pneumonia, particularly the ones with GGO. Therefore, they should not be used as the protocol of choice in the initial imaging of COVID-19 patients during which higher sensitivity is required.

29 April 2022 in Polish Journal of Radiology
Verified
Journal Article
Open access
PDF file
GYGülşah Yıldırım
Gülşah Yıldırım
HKHakki Karakas
Hakki Karakas
Purpose We have investigated the technical and clinical success of percutaneous catheter drainage (PCD) in retroperitoneal abscesses and factors that may affect the outcome. Material and methods The study cohort included 45 patients (17 females and 29 males, with mean age of 56.3 years) that...

5 March 2021 in Diagnostic and Interventional Radiology
Verified
Journal Article
Closed access
GYGülşah Yıldırım
Gülşah Yıldırım
HKHaluk Kilic
Haluk Kilic
HKHakki Muammer Karakas
Hakki Muammer Karakas
Computed tomography (CT) premises are one of the strategic points in the spread of hospital-acquired infections. Ultraviolet germicidal irradiation (UVGI) is an effective method that could potentially be used to purify the ambient air in them. However, it cannot be directly used in the presence of humans and, therefore, it is not operationally suitable in such units with continuous human circulation. Newer devices have been developed to purify air with more efficient and shielded UV-C sources. This study aims to assess the microbial air contamination in CT scanning rooms and investigates the efficacy and technical considerations of shielded UV-C arrays. Two shielded UVGI systems, each equipped with 15 Watt UV-C LED arrays, were tested in a very busy CT unit. Initially, a pilot study was performed to determine ambient microorganisms under routine conditions before UVGI installation, followed by three basic scenarios of UVGI use under normal and abnormal conditions: A, UVGI, with both air-conditioning (AC) and ventilation on; B, UVGI, with AC on and ventilation off; C, UVGI, with both AC and ventilation off. Ambient air was sampled in various time points before and after the initialization of UV irradiation and analyzed for colony formation. The mean total colony count in the pilot study was 1360±450 CFU/m3. Pre-UVGI colony count was 3510 CFU/m3 for Scenario A, ~10000 CFU/m3 for Scenario B and 990 CFU/m3 for Scenario C. Thirty minutes after UVGI, total colony counts in all three scenarios dropped to 30 to 70 CFU/m3. Under normal operating conditions and UVGI, the mean colony count was found as 21.4±13.5 CFU/m3 and the average efficacy of the UVGI was found as 99.39%. This study identified substantial microbial air contamination in CT scanning rooms during normal and abnormal operating conditions. UV-C LED arrays effectively eliminate these microbiological contaminants. This effect is also observed under abnormal operating conditions where no other means of ventilation or air conditioning exists.

26 May 2022 in Journal of the Belgian Society of Radiology
Verified
Journal Article
Open access
PDF file
GYGülşah Yıldırım
Gülşah Yıldırım
HKHakki Muammer Karakas
Hakki Muammer Karakas
The objective is to evaluate the long-term efficacy and safety of uncooled MWA for the treatment of benign thyroid nodules and its long-term effect on thyroid functions. The study was conducted on 40 patients with 40 nodules. They were treated between September 2019 and December 2020. Nodules’ volumes, thyroid functions (triiodothyronine, free thyroxine, thyrotropin) and anti-thyroid peroxidase and anti-thyroglobulin antibodies were measured before treatment and at 3rd, 6th and 12th month following the treatment. Volume reduction rates and changes in clinical findings were evaluated. The mean volume reduction rate was 49.88, 65.3, and 79.06% at 3rd, 6th, and 12th month, respectively. Antibody levels and thyroid function tests have remained within normal limits and were not exhibited significant change during follow-ups (p > 0.05), except for a significant increase in free thyroxin level at 12th-month (p = 0.007). Subjective symptoms and cosmetic scores were significantly improved all follow-up (p < 0.0001). The only complication was a first-degree skin burn in a patient. In conclusion, uncooled microwave ablation is an effective and safe method for the treatment of benign thyroid nodules and preserves thyroid function.

27 October 2022 in Northern Clinics of Istanbul
Verified
Journal Article
Open access
GYGülşah Yıldırım
Gülşah Yıldırım
HKHakki Karakas
Hakki Karakas
BYBaris Yilmaz
Baris Yilmaz
This study aims to evaluate the technical and clinical success of uncooled microwave ablation (MWA) in the treatment of osteoid osteoma with two-dimensional fluoroscopy guidance in the operating room. The clinical and imaging data of 9 patients were retrospectively evaluated. Mean patient age was 14.55 years. The mean size and volume of the lesions were 17.2 × 10.8 × 8.0 mm and the mean nidus size was 6.86±2.05 mm on computed tomography. MWA was performed with uncooled probe in operating room and in sterile conditions. Numerical pain score was recorded before the procedure, the day after, and at 1, 3 months after the procedure. Clinical and technical success was achieved in 100% of patients. The mean volume of MWA-induced necrosis was 20.8 × 12.8 × 10.7 mm, peripheral scar thickness was 3.5±0.75 mm, and none of the patients had nidus enhancement on first month follow-up magnetic resonance imaging. Fluoroscopic guidance was conducted under digital c-arm. Patients received four to 12 spot films (mean: 6.6 kVp, 2.66 mAs) over the lower extremity. Mean radiation exposure to the skin due to imaging was 0.02 mGy per patient per procedure. The dose area product-the total amount of radiation deliverable to the patient was 0.75±0.32 Gy.cm2. This study demonstrated the effectiveness and the safety of the uncooled MWA in osteoid osteoma. The technique may effectively be used in operating room under c-arm fluoroscopy. Such hybrid approach may ensure sterility, anesthetic safety, and lower radiation dose to patients.